Detailed Monte Carlo simulation of energy integrating and photon counting semiconductor detectors

被引:0
|
作者
Mendesa, Hitalo R. [1 ]
Tomala, Alessandra [1 ]
机构
[1] Univ Estadual Campinas, Gleb Wataghin Inst Phys, BR-13057413 Campinas, SP, Brazil
来源
MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING | 2022年 / 12031卷
基金
瑞典研究理事会;
关键词
Monte Carlo simulation; detection; energy integrating; photon counting;
D O I
10.1117/12.2607891
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
X-ray imaging techniques widely employ semiconductor detectors. Energy integrating (EI) detectors are used in digital radiography and photon counting (PC) in CT. This work aims to implement a detailed Monte Carlo modeling of these sensors. The model was divided into radiation interaction and electron-hole pairs (EHP) creation and dispersion. The PENELOPE code simulated the radiation transport. In each electron interaction, the absorbed energy was converted into EHP considering the pair creation energy and the Fano factor. The detection position was sampled using a Gaussian distribution, where the standard deviation was from the Einstein diffusion equation. The Hetch equation models the charge trapping. In the PC mode, the photon was counted if the energy deposited was higher than a threshold (ethr). Monoenergetic pencil beams between 10 and 100 keV were simulated, with 107 histories. The detector material was cadmium tellurite, with 50 mu m pixel size, whose thicknesses, applied electric field, and ethr vary, respectively from 250 to 1000 mu m, 0.01 to 1 V/mu m, and from 1 to 50 keV. The results show a wider detector response as the beam energy increases. For energies above 32 keV the fluorescence is greatly responsible for this spread. The detector's efficiency increases with the sensor thickness and decreases with the photon energy. Charge trapping decreases the efficiency up to 43,53%. For the PC mode, an ethr increase yields a narrower detector response and increases the image noise. This study provides a detailed detector modeling and, consequently, insight into the imaging system's fundamental limitations.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] The effect of energy weighting on x-ray imaging based on photon counting detector: a Monte Carlo simulation
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    MEDICAL IMAGING 2012: PHYSICS OF MEDICAL IMAGING, 2012, 8313
  • [22] Photon energy absorption coefficients for nuclear track detectors using Geant4 Monte Carlo simulation
    Singh, Vishwanath P.
    Medhat, M. E.
    Badiger, N. M.
    RADIATION PHYSICS AND CHEMISTRY, 2015, 106 : 83 - 87
  • [23] Monte Carlo simulations of the energy response of γ-ray dosimeters with CdZnTe semiconductor detectors
    Department of Engineering Physics, Tsinghua University, Beijing 100084, China
    Qinghua Daxue Xuebao, 2007, SUPPL. 1 (1005-1008):
  • [24] Monte-Carlo Simulation of the Detective Quantum Efficiency of Cadmium Telluride X-Ray Detectors for Photon-Counting Mammography
    Day, J.
    Tanguay, J.
    MEDICAL PHYSICS, 2021, 48 (06)
  • [25] Monte Carlo simulation variance reduction techniques for photon transport in liquid xenon detectors
    Bruenner, S.
    Colijn, A. P.
    Decowski, M. P.
    Kesber, O., V
    JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS, 2021, (03):
  • [26] SIMULATION OF HGI2 SEMICONDUCTOR-DETECTORS BY A MONTE-CARLO METHOD
    MANFREDOTTI, C
    NASTASI, U
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1984, 225 (01): : 138 - 144
  • [27] Monte Carlo simulation for the electron cascade due to gamma rays in semiconductor radiation detectors
    Narayan, Raman D.
    Miranda, Ryan
    Rez, Peter
    JOURNAL OF APPLIED PHYSICS, 2012, 111 (06)
  • [28] Influence of photon energy cuts on PET Monte Carlo simulation results
    Mitev, Krasimir
    Gerganov, Georgi
    Kirov, Assen S.
    Schmidtlein, C. Ross
    Madzhunkov, Yordan
    Kawrakow, Lwan
    MEDICAL PHYSICS, 2012, 39 (07) : 4175 - 4186
  • [29] Monte Carlo simulation for photon energy response from the RADOS dosemeter
    Ferreira, Max da Silva
    RADIATION PROTECTION DOSIMETRY, 2024, 200 (08) : 739 - 744
  • [30] A Monte Carlo simulation study of the effect of energy windows in computed tomography images based on an energy-resolved photon counting detector
    Lee, Seung-Wan
    Choi, Yu-Na
    Cho, Hyo-Min
    Lee, Young-Jin
    Ryu, Hyun-Ju
    Kim, Hee-Joung
    PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (15): : 4931 - 4949