Assessing Corneal Hysteresis Using the Ocular Response Analyzer

被引:41
作者
McMonnies, Charles W. [1 ]
机构
[1] Univ New S Wales, Sch Optometry & Vis Sci, Sydney, NSW, Australia
关键词
biomechanics; hysteresis; cornea; ocular response analyzer; INTRAOCULAR-PRESSURE; BIOMECHANICAL PROPERTIES; BOVINE CORNEA; IN-VIVO; THICKNESS; EYES; GLAUCOMA; PARAMETERS; KERATOCONUS; EDEMA;
D O I
10.1097/OPX.0b013e3182417223
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. An examination of studies that have assessed corneal biomechanical performance using the Ocular Response Analyzer (ORA: Reichert Ophthalmic Instruments, Depew, NY) raises some questions regarding the influence of measurement variables and the interpretation of the findings obtained with this instrument. This analysis of those questions describes additional factors which do or may contribute to the assessment of corneal hysteresis (CH). Methods. Using key words CH and ORA, English language articles relevant to this analysis were selected after a PubMed search with the addition of some articles referenced in the selected publications. Results. Corneal thickness, the level of edema, intraocular pressure, and corneal temperature as well as the area, location, rate, duration, and sequence of corneal unloading and loading may need to be considered as significant variables when assessing CH. Conclusions. CH values may be specific to measurement method and conditions rather than representing an unequivocal corneal property. Consideration of the uncontrolled variables involved may help explain some of the findings obtained with the ORA. That a CH measurement might vary with the sequence of unloading and loading suggests that the ORA CH finding may not represent the CH, but instead represents a hysteresis value better described as central, applanation-derived hysteresis, which is based on a very short unloading/loading sequence. The potential for the ORA to contribute to improved clinical management appears to be considerable but so does the need for better understanding and further development of its functions and applications. (Optom Vis Sci 2012;89:E343-E349)
引用
收藏
页码:E343 / E349
页数:7
相关论文
共 58 条
[1]   Corneal hysteresis measured with the Ocular Response Analyzer® in normal and glaucomatous eyes [J].
Abitbol, Olivia ;
Bouden, Jihene ;
Doan, Serge ;
Hoang-Xuan, Thanh ;
Gatinel, Damien .
ACTA OPHTHALMOLOGICA, 2010, 88 (01) :116-119
[2]  
Basli E, 2010, ACTA OPHTHALMOL, V88, pS246
[3]  
Bell F., 1998, PRINCIPLES MECH BIOM
[5]   Mapping collagen organization in the human cornea: Left and right eyes are structurally distinct [J].
Boote, C ;
Hayes, S ;
Abahussin, M ;
Meek, KM .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :901-908
[6]   Stress-controlled viscoelastic tensile response of bovine cornea [J].
Boyce, B. L. ;
Jones, R. E. ;
Nguyen, T. D. ;
Grazier, J. M. .
JOURNAL OF BIOMECHANICS, 2007, 40 (11) :2367-2376
[7]   Full-field deformation of bovine cornea under constrained inflation conditions [J].
Boyce, Brad L. ;
Grazier, J. Mark ;
Jones, Reese E. ;
Nguyen, Thao D. .
BIOMATERIALS, 2008, 29 (28) :3896-3904
[8]   Central corneal thickness and corneal hysteresis associated with glaucoma damage [J].
Congdon, NG ;
Broman, AT ;
Bandeen-Roche, K ;
Grover, D ;
Quigley, HA .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2006, 141 (05) :868-875
[9]   Biomechanical Properties of the Cornea in Fuchs' Corneal Dystrophy [J].
del Buey, Maria A. ;
Cristobal, Jose A. ;
Ascaso, Francisco J. ;
Lavilla, Laura ;
Lanchares, Elena .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (07) :3199-3202
[10]  
Doughty Michael J, 2004, Clin Exp Optom, V87, P81