Evaluation of CT coronary artery angiography with 320-row detector CT in a high-risk population

被引:19
作者
Gang, S. [1 ]
Min, L. [1 ]
Li, L. [1 ]
Guo-Ying, L. [1 ]
Lin, X. [2 ]
Qun, J. [2 ]
Hua, Z. [1 ]
机构
[1] Jinan Mil Gen Hosp 25, Dept Med Imaging, Jinan 250031, Shandong, Peoples R China
[2] Jinan Mil Gen Hosp 25, Dept Cardiol, Jinan 250031, Shandong, Peoples R China
关键词
SPIRAL COMPUTED-TOMOGRAPHY; HEART-RATE-VARIABILITY; DUAL-SOURCE CT; IMAGE QUALITY; DIAGNOSTIC-ACCURACY; ROW CT; RADIATION-EXPOSURE; STENOSES; DISEASE; RECONSTRUCTION;
D O I
10.1259/bjr/90347290
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: The aim of this article was to prospectively evaluate the accuracy and radiation dose of 320-detector row dynamic volume CT (DVCT) for the detection of coronary artery disease (CAD) in a high-risk population. Methods: 60 patients with a high risk of CAD underwent DVCT without preceding heart rate control and also underwent invasive coronary angiography (ICA), which served as the standard reference. Results: On a per segment analysis, overall sensitivity was 95.3%, specificity was 97.6%, positive predictive value was 90.6%, negative predictive value was 98.8% and Youden index was 0.93. In both heart rate subgroups, diagnostic accuracy for the assessment of coronary artery stenosis was similar. The accuracy of the subgroup with an Agatston score >= 100 was lower than that for patients with an Agatston score <100. However, the difference between DVCT and ICA results was not significant (p=0.08). The mean estimated effective dose of CT was 12.5 +/- 9.4 mSv. In those patients with heart rates less than 70 beats per minute (bpm), the mean radiation exposure of DVCT was 5.2 +/- 0.9 mSv. The effective radiation dose was significantly lower than that of ICA (14.1 +/- 5.9 mSv) (p<0.001). When the heart rate was >70 bpm, a significantly higher dose was delivered to patients with DVCT (22.6 +/- 5.2 mSv, p<0.001) than with ICA (15.0 +/- 5.3 mSv, p<0.001). Conclusion: DVCT reliably provides high diagnostic accuracy without heart rate/rhythm control. However, from a dosimetric point of view, it is recommended that heart rate should be controlled to <70 bpm to decrease radiation dose.
引用
收藏
页码:562 / 570
页数:9
相关论文
共 40 条
[11]   Guidelines on the management of stable angina pectoris: executive summary [J].
Fox, Kim ;
Angeles Alonso Garcia, Maria ;
Ardissino, Diego ;
Buszman, Pawel ;
Katowice ;
Camici, Paolo G. ;
Crea, Filippo ;
Daly, Caroline ;
De Backer, Guy ;
Ghent ;
Hjemdahl, Paul ;
Lopez-Sendon, Jose ;
Marco, Jean ;
Morais, Joao ;
Leiria ;
Pepper, John ;
Sechtem, Udo ;
Simoons, Maarten ;
Thygesen, Kristian ;
Priori, Silvia G. ;
Blanc, Jean-Jacques ;
Budaj, Andrzej ;
Camm, John ;
Dean, Veronica ;
Deckers, Jaap ;
Dickstei, Kenneth ;
Lekakis, John ;
McGregor, Keith ;
Metra, Marco ;
Morais, Joao ;
Osterspey, Ady ;
Tamargo, Juan ;
Zamorano, Jose L. ;
Andreotti, Felicita ;
Becher, Harald ;
Dietz, Rainer ;
Fraser, Alan ;
Hernandez Antolin, Rosa Ana ;
Huber, Kurt ;
Kremastinos, Dimitris T. ;
Maseri, Attilio ;
Nesser, Hans-Joachim ;
Pasierski, Tomasz ;
Sigwart, Ulrich ;
Tubaro, Marco ;
Weis, Michael .
EUROPEAN HEART JOURNAL, 2006, 27 (11) :1341-1381
[12]   Accuracy of 16-row multidetector computed tomography for the assessment of coronary artery stenosis [J].
Garcia, Mario J. ;
Lessick, Jonathan ;
Hoffmann, Martin H. K. .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 296 (04) :403-411
[13]   First head-to-head comparison of effective radiation dose from low-dose 64-slice CT with prospective ECG-triggering versus invasive coronary angiography [J].
Herzog, B. A. ;
Wyss, C. A. ;
Husmann, L. ;
Gaemperli, O. ;
Valenta, I. ;
Treyer, V. ;
Landmesser, U. ;
Kaufmann, P. A. .
HEART, 2009, 95 (20) :1656-1661
[14]   Multi-detector row CT coronary angiography: Influence of reconstruction technique and heart rate on image quality [J].
Herzog, C ;
Arning-Erb, M ;
Zangos, S ;
Eichler, K ;
Hammerstingl, R ;
Dogan, S ;
Ackermann, H ;
Vogl, TJ .
RADIOLOGY, 2006, 238 (01) :75-86
[15]  
Hoe John, 2009, J Cardiovasc Comput Tomogr, V3, P257, DOI 10.1016/j.jcct.2009.05.013
[16]   Noninvasive coronary angiography with 16-detector row CT: Effect of heart rate [J].
Hoffmann, MHK ;
Shi, HS ;
Manzke, R ;
Schmid, FT ;
De Vries, L ;
Grass, M ;
Brambs, HR ;
Aschoff, AJ .
RADIOLOGY, 2005, 234 (01) :86-97
[17]   ECG-gated reconstructed multi-detector row CT coronary angiography:: Effect of varying trigger delay on image quality [J].
Hong, C ;
Becker, CR ;
Huber, A ;
Schoepf, UJ ;
Ohnesorge, B ;
Knez, A ;
Brüning, R ;
Reiser, MF .
RADIOLOGY, 2001, 220 (03) :712-717
[18]  
Huda W, 2008, RADIOLOGY, V248, P321, DOI 10.1148/radiol.2481080042
[19]  
Husmann L, 2008, EUR HEART J, V29, P191, DOI 10.1093/eurheartj/ehm613
[20]   Prospective ECG-gated 320 row detector computed tomography: implications for CT angiography and perfusion imaging [J].
Kitagawa, Kakuya ;
Lardo, Albert C. ;
Lima, Joao A. C. ;
George, Richard T. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 :201-208