Biomechanical examination of the 'plateau phenomenon' in ActiGraph vertical activity counts

被引:50
作者
John, Dinesh [1 ]
Miller, Ross [1 ]
Kozey-Keadle, Sarah [1 ]
Caldwell, Graham [1 ]
Freedson, Patty [1 ]
机构
[1] Univ Massachusetts, Dept Kinesiol, Amherst, MA 01003 USA
关键词
ActiGraph; leveling-off; plateau; physical activity; ARTIFICIAL NEURAL-NETWORK; GROUND REACTION FORCES; PHYSICAL-ACTIVITY; WALKING; SPEED; ACCELEROMETER; FREQUENCY;
D O I
10.1088/0967-3334/33/2/219
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
This paper determines if the leveling off ('plateau/inverted-U' phenomenon) of vertical ActiGraph activity counts during running at higher speeds is attributable to the monitor's signal filtering and acceleration detection characteristics. Ten endurance-trained male participants (mean (SD) age = 28.2 (4.7) years) walked at 3, 5 and 7 km h(-1), and ran at 8, 10, 12, 14, 16, 18 and 20 km h(-1) on a force treadmill while wearing an ActiGraph GT3X monitor at the waist. Triaxial accelerations of the body's center of mass (CoM) and frequency content of these accelerations were computed from the force treadmill data. GT3X vertical activity counts demonstrated the expected 'plateau/inverted-U' phenomenon. In contrast, vertical CoM accelerations increased with increasing speed (1.32 +/- 0.26 g at 10 km h(-1) and 1.68 +/- 0.24 g at 20 km h(-1)). The dominant frequency in the CoM acceleration signals increased with running speed (14.8 +/- 3.2 Hz at 10 km h-1 and 24.8 +/- 3.2 Hz at 20 km h(-1)) and lay beyond the ActiGraph band-pass filter (0.25 to 2.5 Hz) limits. In conclusion, CoM acceleration magnitudes during walking and running lie within the ActiGraph monitor's dynamic acceleration detecting capability. Acceleration signals of higher frequencies that are eliminated by the ActiGraph band-pass filter may be necessary to distinguish among exercise intensity at higher running speeds.
引用
收藏
页码:219 / 230
页数:12
相关论文
共 25 条
[1]   FOURIER-ANALYSIS OF FORCES EXERTED IN WALKING AND RUNNING [J].
ALEXANDER, RM ;
JAYES, AS .
JOURNAL OF BIOMECHANICS, 1980, 13 (04) :383-390
[2]   THE FREQUENCY CONTENT OF GAIT [J].
ANTONSSON, EK ;
MANN, RW .
JOURNAL OF BIOMECHANICS, 1985, 18 (01) :39-47
[3]   A triaxial accelerometer and portable data processing unit for the assessment of daily physical activity [J].
Bouten, CVC ;
Koekkoek, KTM ;
Verduin, M ;
Kodde, R ;
Janssen, JD .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1997, 44 (03) :136-147
[4]   Reexamination of validity and reliability of the CSA monitor in walking and running [J].
Brage, S ;
Wedderkopp, N ;
Franks, PW ;
Andersen, LB ;
Froberg, K .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2003, 35 (08) :1447-1454
[5]   Development of postural control of gravity forces in children during the first 5 years of walking [J].
Brenière, Y ;
Bril, B .
EXPERIMENTAL BRAIN RESEARCH, 1998, 121 (03) :255-262
[6]   SOURCES OF EXTERNAL WORK IN LEVEL WALKING AND RUNNING [J].
CAVAGNA, GA ;
THYS, H ;
ZAMBONI, A .
JOURNAL OF PHYSIOLOGY-LONDON, 1976, 262 (03) :639-657
[7]   Metabolic cost of generating horizontal forces during human running [J].
Chang, YH ;
Kram, R .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 86 (05) :1657-1662
[8]  
DERRICK TR, 1994, MED SCI SPORT EXER, V26, P919
[9]   Evaluation of artificial neural network algorithms for predicting METs and activity type from accelerometer data: validation on an independent sample [J].
Freedson, Patty S. ;
Lyden, Kate ;
Kozey-Keadle, Sarah ;
Staudenmayer, John .
JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (06) :1804-1812
[10]   Estimation of oxygen uptake during fast running using accelerometry and heart rate [J].
Fudge, Barry W. ;
Wilson, John ;
Easton, Chris ;
Irwin, Laura ;
Clark, Jonathan ;
Haddow, Olivia ;
Kayser, Bengt ;
Pitsiladis, Yannis P. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2007, 39 (01) :192-198