Critical aspects of new domestic static gas meter

被引:0
作者
Celenza, L. [1 ]
Dell'Isola, M. [1 ]
Ficco, G. [1 ]
Vigo, P. [2 ]
Bertoli, E. [3 ]
Incerti, L. [3 ]
Zocchi, T. [3 ]
机构
[1] Univ Cassino & Southern Lazio, Dept Civil & Mech Engn, DICEM, Via G Di Biasio 43, I-03043 Cassino, Italy
[2] PALMER, Sci & Tech Pk Southern Lazio, I-03013 Ferentino, Italy
[3] CPL Concordia, I-41033 Concordia Sulla Secchia, Italy
来源
2015 18TH AISEM ANNUAL CONFERENCE | 2015年
关键词
smart metering; thermal mass; static meter; gas quality; capillary; MEMS; TRANSMISSION NETWORKS;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
To promote the diffusion of smart metering, several National Authorities defined strict roll-out procedures of the existing meters with new smart meters. In such scenario, even if new static technologies in gas metering offer very significant potential (such as digital output, absence of moving parts, direct mass measurement), their reliability in some critical conditions typical of natural gas distribution networks (i.e. zero flow, minimum flow-rate, gas quality changes, presence of dust and contaminants, etc.) still has to be demonstrated. A very promising technology for natural gas domestic measurements is represented by thermal mass flow meters, but, unfortunately, gas quality is expected to significantly affect metrological performance of such meters. The authors conducted several metrological tests aimed to verify the sensitivity of such meter with natural gas quality changes. The results of these tests show a not full reliability when CO2 content increases and when gas composition varies.
引用
收藏
页数:4
相关论文
共 11 条
  • [1] Gas mass-flow meters: Principles and applications
    Amador de Matos, Manuel Arlindo
    Ferreira, Viviana da Silva
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2010, 21 (02) : 143 - 149
  • [2] [Anonymous], 4372003A12009 EN
  • [3] [Anonymous], 2014, 11537 UNI TR
  • [4] [Anonymous], 2006, 1359 EN
  • [5] [Anonymous], 2007, 14236 EN
  • [6] Unaccounted for gas in natural gas transmission networks: Prediction model and analysis of the solutions
    Arpino, F.
    Dell'Isola, M.
    Ficco, G.
    Vigo, P.
    [J]. JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2014, 17 : 58 - 70
  • [7] Betta G., 1996, Measurement, V17, P115, DOI 10.1016/0263-2241(96)00019-X
  • [8] Buonanno G., 1998, Measurement, V23, P77, DOI 10.1016/S0263-2241(98)00009-8
  • [9] Dell'Isola M., 1997, Measurement, V20, P75, DOI 10.1016/S0263-2241(97)00016-X
  • [10] Uncertainty analysis of energy measurements in natural gas transmission networks
    Ficco, G.
    Dell'Isola, M.
    Vigo, P.
    Celenza, L.
    [J]. FLOW MEASUREMENT AND INSTRUMENTATION, 2015, 42 : 58 - 68