Coupled simulation of BES-CFD and performance assessment of energy recovery ventilation system for office model

被引:15
作者
Fan, Yunqing [1 ]
Hayashi, T. [1 ]
Ito, K. [1 ]
机构
[1] Kyushu Univ, IGSES, Fukuoka 812, Japan
关键词
building energy simulation; computational fluid dynamics (CFD); FLUENT; TRNSYS; energy saving; COMPUTATIONAL FLUID-DYNAMICS; BUILDING ENERGY;
D O I
10.1007/s11771-012-1049-7
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Thermal comfort and indoor air quality as well as the energy efficiency have been recognized as essential parts of sustainable building assessment. This work aims to analyze the energy conservation of the heat recovery ventilator and to investigate the effect of the air supply arrangement. Three types of mixing ventilation are chosen for the analysis of coupling ANSYS/FLUENT (a computational fluid dynamics (CFD) program) with TRNSYS (a building energy simulation (BES) software). The adoption of mutual complementary boundary conditions for CFD and BES provides more accurate and complete information of indoor air distribution and thermal performance in buildings. A typical office-space situated in a middle storey is chosen for the analysis. The office-space is equipped with air-conditioners on the ceiling. A heat recovery ventilation system directly supplies fresh air to the office space. Its thermal performance and indoor air distribution predicted by the coupled method are compared under three types of ventilation system. When the supply and return openings for ventilation are arranged on the ceiling, there is no critical difference between the predictions of the coupled method and BES on the energy consumption of HVAC because PID control is adopted for the supply air temperature of the occupied zone. On the other hand, approximately 21% discrepancy for the heat recovery estimation in the maximum between the simulated results of coupled method and BES-only can be obviously found in the floor air supply ventilation case. The discrepancy emphasizes the necessity of coupling CFD with BES when vertical air temperature gradient exists. Our future target is to estimate the optimum design of heat recovery ventilation system to control CO2 concentration by adjusting flow rate of fresh air.
引用
收藏
页码:633 / 638
页数:6
相关论文
共 16 条
  • [1] ANSYS. ANSYS/FLUENT 12, 2009, ANSYS FLUENT 12
  • [2] Arias D, 2006, 2 NAT IBPSA US C SIM, P231
  • [3] Integrating CFD and building simulation
    Bartak, M
    Beausoleil-Morrison, I
    Clarke, JA
    Denev, J
    Drkal, F
    Lain, M
    Macdonald, IA
    Melikov, A
    Popiolek, Z
    Stankov, P
    [J]. BUILDING AND ENVIRONMENT, 2002, 37 (8-9) : 865 - 871
  • [4] Contrasting the capabilities of building energy performance simulation programs
    Crawley, Drury B.
    Hand, Jon W.
    Kurnmert, Michal
    Griffith, Brent T.
    [J]. BUILDING AND ENVIRONMENT, 2008, 43 (04) : 661 - 673
  • [5] Djunaedy E., 2005, ASHRAE T, P612
  • [6] KLEIN SA, 2006, TRNSYS
  • [7] Measurement and CFD simulation of the temperature stratification in an atrium using a floor level air supply method
    Lau, J
    Niu, JL
    [J]. INDOOR AND BUILT ENVIRONMENT, 2003, 12 (04) : 265 - 280
  • [8] Integration of computational fluid dynamics with building thermal and mass flow simulation
    Negrao, COR
    [J]. ENERGY AND BUILDINGS, 1998, 27 (02) : 155 - 165
  • [9] Ventilation and performance in office work
    Seppänen, O
    Fisk, WJ
    Lei, QH
    [J]. INDOOR AIR, 2006, 16 (01) : 28 - 36
  • [10] Sorensen DN, 2003, INDOOR AIR, V13, P2