Negative Sequence Control of DFG based Wind Turbines

被引:0
作者
Engelhardt, S. [1 ]
Kretschmann, J. [1 ]
Fortmann, J.
Shewarega, F. [2 ]
Erlich, I.
Feltes, C.
机构
[1] Woodward Kempen GmbH, D-47906 Kempen, Germany
[2] Univ Duisburg, Duisburg, Germany
来源
2011 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING | 2011年
关键词
wind turbine; doubly-fed induction generator; DFIG; negative sequence control; COMPENSATION; GENERATOR;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The paper deals with the control of negative sequence voltages and currents in wind turbine systems caused by grid fault or unsymmetrical system operation. The ensuing stator and rotor currents lead to additional thermal stress. Moreover, the interaction between the different sequence components of the current and voltage in the stator as well as rotor cause oscillating torque leading to mechanical strain on the drive-train. A control approach for limiting or eliminating the negative sequence current and the resulting alternating torque is discussed. This is followed by the description and derivation of the rotor side converter (RSC) for the positive as well as negative sequence current controllers. The procedure is repeated for the grid side converter (GSC), and the limitations imposed on the controllers by practical operational considerations are explained. On the basis of simulation examples using representative wind turbine system data, the effectiveness of the proposed control methods has been demonstrated.
引用
收藏
页数:8
相关论文
共 14 条
  • [1] Control of back-to-back PWM converters for DFIG wind turbine systems under unbalanced grid voltage
    Abo-Khalil, Ahmed G.
    Lee, Dong-Choon
    Jang, Jeong-Ik
    [J]. 2007 IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS, PROCEEDINGS, VOLS 1-8, 2007, : 2637 - +
  • [2] [Anonymous], 6140021 IEC
  • [3] BMU, 2009, ORD SYST SERV WIND E
  • [4] Brekken T., 2003, 2003 IEEE 34th Annual Power Electronics Specialists Conference. Conference Proceedings (Cat. No.03CH37427), P760
  • [5] Control of a doubly fed induction wind generator under unbalanced grid voltage conditions
    Brekken, Ted K. A.
    Mohan, Ned
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) : 129 - 135
  • [6] Engelhardt S., 2010, THESIS U DUISBURG ES
  • [7] Engelhardt S., 2009, INT WORKSH LARG SCAL
  • [8] Modeling of wind turbines based on doubly-fed induction generators for power system stability studies
    Erlich, Istvan
    Kretschmann, Joerg
    Fortmann, Jens
    Mueller-Engelhardt, Stephan
    Wrede, Holger
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2007, 22 (03) : 909 - 919
  • [9] Jang Jeong-lk, IPEMC 2006 C P
  • [10] LE TN, 1989, ETZ ARCHIV, V11, P249