Reliability Analysis of the 3-min All-Out Exercise Test for Cycle Ergometry

被引:55
作者
Johnson, Tyler M.
Sexton, Patrick J.
Placek, Ashley M.
Murray, Steven R. [2 ]
Pettitt, Robert W. [1 ]
机构
[1] Minnesota State Univ, Dept Human Performance, ATC, CSCS,Viola Holbrook Human Performance Lab, Mankato, MN 56001 USA
[2] Colorado Mesa Univ, Dept Kinesiol, Grand Junction, CO USA
关键词
ANAEROBIC CAPACITY; CRITICAL POWER; POWER-DURATION RELATIONSHIP; MAXIMUM OXYGEN UPTAKE; MAXIMAL OXYGEN-UPTAKE; CRITICAL POWER; WORK CAPACITY; ANAEROBIC THRESHOLD; UPTAKE KINETICS; O-2; UPTAKE; VO2MAX; TOLERANCE; CRITERIA; CONSTANT;
D O I
10.1249/MSS.0b013e318224cb0f
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
JOHNSON, T. M., P. J. SEXTON, A. M. PLACEK, S. R. MURRAY, and R. W. PETTITT. Reliability Analysis of the 3-min All-Out Exercise Test for Cycle Ergometry. Med. Sci. Sports Exerc., Vol. 43, No. 12, pp. 2375-2380, 2011. The 3-min all-out exercise test (3 MT) is purported to estimate critical power (CP) and anaerobic work capacity (W') and serve as an exercise mode for measuring maximum oxygen uptake ((V) over dotO(2max)). Reliability analysis of the 3 MT has been confined to CP, not W', and verification of "true" (V) over dotO(2max) was exclusive to a graded exercise test (GXT). Purpose: We conducted a reliability analysis of the 3 MT and compared (V) over dotO(2max) values from the 3 MT with a GXT and an exhaustive square-wave verification bout. Methods: Upon completion of a custom GXT and square-wave verification protocol, 11 subjects of various aerobic powers completed two 3 MTs (separate visits). CP, W', average power during 150 s from the 3 MT, and (V) over dotO(2max) values were assessed using typical error (TE), coefficient of variation (CV), and intraclass correlation (alpha). Results: CP (W) (trial 1 = 206 +/- 47, trial 2 = 206 +/- 42) did not differ between 3 MT trials (P = 0.37) and was reliable (TE = 15 W, CV = 7%, alpha = 0.93). W' was less reliable (TE = 2864 J, CV = 28%, alpha = 0.76) but did not alter power-duration estimates from the two 3 MTs (P > 0.05). Variability for (V) over dotO(2max) (TE (mL.kg(-1).min(-1))) between the GXT and the verification bout (1.16) was more consistent than the first (2.03) or second (2.69) 3 MT. Conclusions: The 3 MT yields reliable estimates of CP and consistent estimates of the power-duration relationship. Power for 150 s, in comparison with W', is a more reliable metric of short-term power performance. The square-wave protocol is recommended over the 3 MT for verifying true (V) over dotO(2max).
引用
收藏
页码:2375 / 2380
页数:6
相关论文
共 36 条
  • [1] American College of Sports Medicine, 2010, ACSMS GUIDELINES EXE, V8th, P158
  • [2] Human critical power-oxygen uptake relationship at different pedalling frequencies
    Barker, T
    Poole, DC
    Noble, ML
    Barstow, TJ
    [J]. EXPERIMENTAL PHYSIOLOGY, 2006, 91 (03) : 621 - 632
  • [3] A NEW METHOD FOR DETECTING ANAEROBIC THRESHOLD BY GAS-EXCHANGE
    BEAVER, WL
    WASSERMAN, K
    WHIPP, BJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (06) : 2020 - 2027
  • [4] BORG G, 1970, Scandinavian Journal of Rehabilitation Medicine, V2, P92
  • [5] Oxygen uptake kinetics as a determinant of sports performance
    Burnley, Mark
    Jones, Andrew M.
    [J]. EUROPEAN JOURNAL OF SPORT SCIENCE, 2007, 7 (02) : 63 - 79
  • [6] A 3-min all-out test to determine peak oxygen uptake and the maximal steady state
    Burnley, Mark
    Doust, Jonathan H.
    Vanhatalo, Anni
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2006, 38 (11) : 1995 - 2003
  • [7] The maximally attainable Vo2 during exercise in humans:: the peak vs. maximum issue
    Day, JR
    Rossiter, HB
    Coats, EM
    Skasick, A
    Whipp, BJ
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2003, 95 (05) : 1901 - 1907
  • [8] Determination of critical power from a single test
    Dekerle, J.
    Vanhatalo, A.
    Burnley, A.
    [J]. SCIENCE & SPORTS, 2008, 23 (05) : 231 - 238
  • [9] Validity of the two-parameter model in estimating the anaerobic work capacity
    Dekerle, J
    Brickley, G
    Hammond, AJP
    Pringle, JSM
    Carter, H
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2006, 96 (03) : 257 - 264
  • [10] Defining Intensity Domains from the End Power of a 3-min All-out Cycling Test
    Francis, James T., Jr.
    Quinn, Timothy J.
    Amann, Markus
    LaRoche, Dain P.
    [J]. MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (09) : 1769 - 1775