Clinical Utility of HIV-1/2 Ab Immunochromatographic Assay as an Additive Test for HIV Screen-Positive Patients

被引:0
作者
Yoo, Soo Jin [1 ]
机构
[1] Inje Univ, Sanggye Paik Hosp, Dept Lab Med, Coll Med, 1342 Dongil Ro, Seoul 01757, South Korea
关键词
HIV; Immunochromatographic assay; Rapid diagnostic test;
D O I
暂无
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Objective. Frequent false-positive results of current HIV screening occur due to its high sensitivity. These false-positives may delay subsequent clinical decision making. In this study, we aim to determine the usefulness of additional immunochromatographic assay (ICA) in hospitals using fourth-generation HIV-1/2 Ag/Ab assays followed by western blot (WB) confirmation. Methods. Overall, 158,431 patients' sera were screened for HIV using a fourth-generation HIV-1/2 Ag/Ab assays (Elecsys HIV combiPT) from July 2011 to May 2019. All 401 ECLIA-positive sera were re-tested using an ICA kit (SD Bioline HIV1/2 3.0 ICA), followed by WB confirmation according to national policy. Results. Sixty-five ECLIA-positive samples (65/401, 16.2%) were positive for ICA, 96.9% (63/65) of which were confirmed positive using WB. ICA results were negative in 83.8% (336/401) of ECLIA-positive samples, of which 98.5% (331/336) remained negative on WB. Five specimens (1.5%) from patients with symptoms consistent with acute HIV syndrome were false negatives on ICA. These false negatives were confirmed positive using a p24 antigen assay and nucleic acid test (NAT). Conclusions. ICA for anti-HIV Ab screen-positive specimens is helpful for earlier medical decision considering frequent false-positive results on screening. Nonetheless, ICA might be negative in acute HIV syndrome, necessitating p24 Ag assay or NAT with shorter window periods.
引用
收藏
页码:274 / 277
页数:4
相关论文
共 8 条
  • [1] Accuracy of Rapid Influenza Diagnostic Tests A Meta-analysis
    Chartrand, Caroline
    Leeflang, Mariska M. G.
    Minion, Jessica
    Brewer, Timothy
    Pai, Madhukar
    [J]. ANNALS OF INTERNAL MEDICINE, 2012, 156 (07) : 500 - U80
  • [2] Human immunodeficiency virus: Diagnostic approach
    Guarner, Jeannette
    [J]. SEMINARS IN DIAGNOSTIC PATHOLOGY, 2017, 34 (04) : 318 - 324
  • [3] Korean Centers for Disease Control and Prevention, 2019, 2019 HIV AIDS MAN GU
  • [4] Reduction of the HIV Seroconversion Window Period and False Positive Rate by Using ADVIA Centaur HIV Antigen/Antibody Combo Assay
    Lee, Kyunghoon
    Park, Hyung-Doo
    Kang, Eun-Suk
    [J]. ANNALS OF LABORATORY MEDICINE, 2013, 33 (06) : 420 - 425
  • [5] Evaluation of the Bio-Rad Geenius HIV 1/2 Confirmation Assay as an Alternative to Western Blot in the Korean Population: A Multi-Center Study
    Moon, Hee-Won
    Huh, Hee Jin
    Oh, Gwi Young
    Lee, Sang Gon
    Lee, Anna
    Yun, Yeo-Min
    Hur, Mina
    [J]. PLOS ONE, 2015, 10 (09):
  • [6] The Multispot rapid HIV-1/HIV-2 differentiation assay is comparable with the Western blot and an immunofluorescence assay at confirming HIV infection in a prospective study in three regions of the United States
    Pandori, Mark W.
    Westheimer, Emily
    Gay, Cindy
    Moss, Nicholas
    Fu, Jie
    Hightow-Weidman, Lisa B.
    Craw, Jason
    Hall, Laura
    Giancotti, Francesca R.
    Mak, Mae Ling
    Madayag, Carmela
    Tsoi, Benjamin
    Louie, Brian
    Patel, Pragna
    Owen, S. Michele
    Peters, Philip J.
    [J]. JOURNAL OF CLINICAL VIROLOGY, 2013, 58 : E92 - E96
  • [7] False Positive HIV Diagnoses in Resource Limited Settings: Operational Lessons Learned for HIV Programmes
    Shanks, Leslie
    Klarkowski, Derryck
    O'Brien, Daniel P.
    [J]. PLOS ONE, 2013, 8 (03):
  • [8] The current status of HIV screening laboratories in Korea assessed by a questionnaire survey of participants in the KCDC HIV EQAS (2006)
    Wang, J-S.
    Kee, M. K.
    Kim, H-S.
    Choi, B-S.
    Suh, S-D.
    Kim, E-J.
    Kim, C-W.
    Kim, S. S.
    [J]. CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (05) : 482 - 487