Comparison of the flexural and surface properties of milled, 3D-printed, and heat polymerized PMMA resins for denture bases: An in vitro study

被引:55
作者
Di Fiore, Adolfo [1 ]
Meneghello, Roberto [2 ]
Brun, Paola [3 ]
Rosso, Stefano [2 ]
Gattazzo, Alberto
Stellini, Edoardo [4 ]
Yilmaz, Burak [5 ,6 ,7 ]
机构
[1] Univ Padua, Sch Dent, Dept Neurosci, Sect Prosthodont & Digital Dent, Padua, Italy
[2] Univ Padua, Dept Management & Engn, Padua, Italy
[3] Univ Padua, Dept Mol Med, Padua, Italy
[4] Univ Padua, Univ Dent Clin, Sch Dent, Dept Neurosci, Padua, Italy
[5] Univ Bern, Sch Dent Med, Dept Reconstruct Dent & Gerodontol, Bern, Switzerland
[6] Univ Bern, Sch Dent Med, Dept Restorat Prevent & Pediat Dent, Bern, Switzerland
[7] Ohio State Univ, Div Restorat & Prosthet Dent, Columbus, OH 43210 USA
关键词
CAD/CAM; 3D-printer; PMMA; Complete denture; Overdenture; POLISHING TECHNIQUES; ACRYLIC RESIN; ROUGHNESS; ADHERENCE; CANDIDA; AGENTS;
D O I
10.2186/jpr.JPR_D_21_00116
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To compare the flexural properties and the adhesion of Lactobacillus salivarius (LS), Streptococcus mutans (SM), and Candida albicans (CA) on heat-polymerized (CV), CAD-CAM milled (CAD), or 3D- printed (3D) Poly (methylmethacrylate) (PMMA). Methods: Ultimate Flexural Strength (UFS), Flexural Strain (FS) (%) at Flexural Strength, and Flexural Modulus (FM) of specimens (65.0x10.0x3.3 mm) from each PMMA group (n=6) were calculated by using the 3-point bending test. The surface roughness profiles (R) were measured before and after polishing with a contact profilometer. LS, SM, and CA adhesion on PMMA specimens (n=18) (10 mm in diameter, 3 mm in height) was assessed after 90 minutes and 16 hours by using scanning electron microscopy. The Kruskal-Wallis test with post hoc analysis was performed to compare the groups (alpha=0.05). Results: Mean UFS values were 80.79 +/- 7.64 MPa for CV, 110.23 +/- 5.03 MPa for CAD, and 87.34 +/- 6.39 MPa for 3D. Mean FS values were 4.37 +/- 1.04% for CV, 4.71 +/- 0.62% for CAD, and 6.19 +/- 0.13 % for 3D. Mean FM values were 2542 +/- 301 MPa for CV, 3435 +/- 346 MPa for CAD, and 2371 +/- 197 MPa for 3D. CAD had the lowest average R value (0.29 +/- 0.16 mu m) before polishing, and bacterial adhesion after 90 minutes of incubation. R value and microbial adhesion were not different amongst groups after polishing and 16 hours of incubation, respectively. Conclusion: The CAD group displayed the best flexural properties, except for FS, the lowest roughness before polishing and bacterial adhesion after 90 minutes of incubation. All tested PMMAs had similar surface roughness after polishing, and microbial adhesion after 16 hours of incubation.
引用
收藏
页码:502 / 508
页数:7
相关论文
共 50 条
  • [21] Flexural properties and fatigue limit of 3D-printed and milled resin-based materials
    Sartori, Neimar
    Sanchez, Said Arturo
    Oliveira, Dayane
    Hosney, Sherif
    Zoidis, Panagiotis
    Martin, William
    Gonzaga, Luiz
    Rocha, Mateus G.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [22] A comparative study of strength and surface properties of permanent 3D-printed resins with CAD-CAM milled fixed dental prostheses
    Gad, Mohammed M.
    Al Mahfoudh, Hoor A.
    Al Mahfuth, Fatimah A.
    Hashim, Kouthar A.
    Khan, Soban Q.
    Al-Qarni, Faisal D.
    Baba, Nadim Z.
    Al-Harbi, Fahad A.
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [23] Evaluation of the Effects of Different Polishing Protocols on the Surface Characterizations of 3D-Printed Acrylic Denture Base Resins: An In Vitro Study
    Al-Dulaijan, Yousif A. A.
    POLYMERS, 2023, 15 (13)
  • [24] Four Different Build Angles in 3D-Printed Complete Denture Bases: A Comparative In Vitro Study
    Kim, Ki Won
    Kim, Sung Yong
    Kim, Seong-A
    Jang, Hee-Won
    Lee, Keun-Woo
    Lee, Yong-Sang
    APPLIED SCIENCES-BASEL, 2024, 14 (18):
  • [25] Evaluation of the Influence of Build Orientation on the Surface Roughness and Flexural Strength of 3D-Printed Denture Base Resin and Its Comparison with CAD-CAM Milled Denture Base Resin
    Alharethi, Naji Ahmad
    EUROPEAN JOURNAL OF DENTISTRY, 2024, 18 (01) : 321 - 328
  • [26] Effects of Smokeless Tobacco on Color Stability and Surface Roughness of 3D-Printed, CAD/CAM-Milled, and Conventional Denture Base Materials: An In Vitro Study
    Mugri, Maryam H. H.
    Jain, Saurabh
    Sayed, Mohammed E. E.
    Halawi, Amjad Hussain Asiri
    Hamzi, Safa Ahmed Ibrahim
    Aljohani, Raniya Abdulaziz Saad
    Madkhali, Zainab Mousa Ali
    Khalid, Asaad
    Jokhadar, Hossam F. F.
    Almarzouki, Mai
    Alhumaidan, Ghaida A. A.
    Alshahrani, Ahid Amer
    Alqahtani, Saeed M. M.
    Alqahtani, Nasser M. M.
    Lunkad, Honey
    BIOMEDICINES, 2023, 11 (02)
  • [27] In-vitro Comparative Evaluation for the Surface Properties and Impact Strength of CAD/CAM Milled, 3D Printed, and Polyamide Denture Base Resins
    Helal, Mohamed A.
    Fadl-Alah, Ahmed
    Baraka, Yasser M.
    Gad, Mohammed M.
    Emam, Abdel-Naser M.
    JOURNAL OF INTERNATIONAL SOCIETY OF PREVENTIVE AND COMMUNITY DENTISTRY, 2022, 12 (01) : 126 - 131
  • [28] Effect of aging on dimensional accuracy and color stability of CAD-CAM milled and 3D-printed denture base resins: a comparative in-vitro study
    Gad, Marwa A.
    Abdelhamid, Ahmed M.
    ElSamahy, Mahmoud
    Abolgheit, Salma
    Hanno, Kenda I.
    BMC ORAL HEALTH, 2024, 24 (01):
  • [29] Fracture toughness of conventional, milled and 3D printed denture bases
    Mann, Ravdeep S.
    Ruse, N. Dorin
    DENTAL MATERIALS, 2022, 38 (09) : 1443 - 1451
  • [30] Compressive and Flexural Strength of 3D-Printed and Conventional Resins Designated for Interim Fixed Dental Prostheses: An In Vitro Comparison
    Pantea, Mihaela
    Ciocoiu, Robert Catalin
    Greabu, Maria
    Ripszky Totan, Alexandra
    Imre, Marina
    Tancu, Ana Maria Cristina
    Sfeatcu, Ruxandra
    Spinu, Tudor Claudiu
    Ilinca, Radu
    Petre, Alexandru Eugen
    MATERIALS, 2022, 15 (09)