A Systematic Investigation of the Best Buffers for Use in Screening by MALDI-Mass Spectrometry

被引:24
作者
Chandler, Jessica [1 ]
Haslam, Carl [1 ]
Hardy, Neil [1 ]
Leveridge, Melanie [1 ]
Marshall, Peter [1 ]
机构
[1] GlaxoSmithKline, Platform Technol & Sci, Gunnels Wood Rd, Stevenage SG1 2NY, Herts, England
关键词
MALDI-MS; mass spectrometry; screening; buffer; ion suppression;
D O I
10.1177/1087057116681726
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Matrix-assisted laser desorption/ionization-mass spectrometry (MALDI-MS) offers a label-free alternative for the screening of biochemical targets in both 1536- and 6144-assay formats, as well as potentially providing increased sensitivity, reproducibility, and the simultaneous detection of multiple assay components within a specified m/z range. Ion suppression effects are one of the principal limitations reported for MS analysis. Within MALDI-MS screening, it has been identified that certain biochemical components incorporated into the assay (e.g., the buffers used to preserve the physiological conditions of the enzyme, salts, and other additives) induce suppression of the analyte ion signals monitored. This poorly understood phenomenon of ion suppression is a key reason the screening community has been reluctant to shift their investigations toward MS methods with reduced sample cleanup. Using acetylcholine as an assay substrate mimic, we have generated robust data to quantify the degree to which the most highly used components (base buffers, additional components, detergents, cell culture media, and other additives) within current screening assays are compatible with MALDI-MS. Here, the most suitable buffers and components, along with their identified optimal concentrations in terms of limiting ion suppression effects, are proposed for use in screening assays measured by MALDI-MS.
引用
收藏
页码:1262 / 1269
页数:8
相关论文
共 8 条
[1]  
Auld DS., 2014, PERSPECT SCI, V1, P56, DOI [10.1016/j.pisc.2013.12.001, DOI 10.1016/J.PISC.2013.12.001]
[2]   Towards high-throughput identification of endocrine disrupting compounds with mass spectrometry [J].
Bovet, Cedric ;
Plet, Benoit ;
Ruff, Marc ;
Eiler, Sylvia ;
Granger, Florence ;
Panagiotidis, Andreas ;
Wenzel, Ryan ;
Nazabal, Alexis ;
Moras, Dino ;
Zenobi, Renato .
TOXICOLOGY IN VITRO, 2009, 23 (04) :704-709
[3]   Normalization in MALDI-TOF imaging datasets of proteins: practical considerations [J].
Deininger, Soeren-Oliver ;
Cornett, Dale S. ;
Paape, Rainer ;
Becker, Michael ;
Pineau, Charles ;
Rauser, Sandra ;
Walch, Axel ;
Wolski, Eryk .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 401 (01) :167-181
[4]   High-throughput mass Spectrometry screening for inhibitors of phosphatidylserine decarboxylase [J].
Forbes, Chris D. ;
Toth, Joshuaine G. ;
Oezbal, Can C. ;
LaMarr, William A. ;
Pendleton, Jennifer A. ;
Rocks, Sandra ;
Gedrich, Richard W. ;
Osterman, David G. ;
Landro, James A. ;
Lumb, Kevin J. .
JOURNAL OF BIOMOLECULAR SCREENING, 2007, 12 (05) :628-634
[5]  
Garrett T, 2013, NORM APPR IM MASS SP
[6]   Identifying Tissue-Specific Signal Variation in MALDI Mass Spectrometric Imaging by Use of an Internal Standard [J].
Pirman, David A. ;
Kiss, Andras ;
Heeren, Ron M. A. ;
Yost, Richard A. .
ANALYTICAL CHEMISTRY, 2013, 85 (02) :1090-1096
[7]   From models to crop species: caveats and solutions for translational metabolomics [J].
Tohge, Takayuki ;
Mettler, Tabea ;
Arrivault, Stephanie ;
Carroll, Adam James ;
Stitt, Mark ;
Fernie, Alisdair R. .
FRONTIERS IN PLANT SCIENCE, 2011, 2
[8]   High-throughput mass-spectroscopy monitoring for multisubstrate enzymes: Determining the kinetic parameters and catalytic activities of glycosyltransferases [J].
Yang, M ;
Brazier, M ;
Edwards, R ;
Davis, BG .
CHEMBIOCHEM, 2005, 6 (02) :346-357