Development of a nozzle capillary viscometer for inline viscosity measurement of thermoplastics

被引:4
|
作者
Wappler, Peter [1 ]
Horter, Tim [1 ]
Kulkarni, Romit [1 ]
Guenther, Thomas [1 ,2 ]
Fritz, Karl-Peter [1 ]
Zimmermann, Andre [1 ,2 ]
机构
[1] Hahn Schickard, D-70569 Stuttgart, Germany
[2] Univ Stuttgart, Inst Micro Integrat IFM, D-70569 Stuttgart, Germany
关键词
Thermoplastic injection molding; Inline rheometer; Viscosity; Nozzle capillary viscometer; Steady state simulation; Integration boundary influences; INJECTION-MOLDING MACHINE; FLOW;
D O I
10.1007/s00170-021-08394-4
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Todays continuous improvement and advancement in the injection molding process for plastics allow for increasing reliability of the process parameter control, whereas the fluctuations of the material properties still present a great challenge. To compensate for these fluctuations, a nozzle capillary rheometer is developed with the aim to determine the viscosity inline during the injection process in series production applications. An essential part of this work is the signal processing and the definition of a suitable integration boundary to ensure a reliable signal evaluation. In addition, based on mathematical modeling and established correction factors, it is possible to determine the effective viscosity accurately without the need to replace the capillary channel according to the Bagley correction.
引用
收藏
页码:105 / 116
页数:12
相关论文
共 50 条
  • [31] A MODIFIED UBBELOHDE VISCOMETER FOR MEASUREMENT OF VISCOSITY OF POLYMER SOLUTIONS
    HUGHES, J
    RHODEN, F
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (12): : 1134 - &
  • [32] AN ULTRASONIC VISCOMETER FOR THE MEASUREMENT OF DYNAMIC SHEAR VISCOSITY OF LIQUIDS
    BINDAL, VN
    CHANDRA, M
    SOM, JN
    INDIAN JOURNAL OF PURE & APPLIED PHYSICS, 1983, 21 (03) : 176 - 179
  • [33] VISCOSITY MEASUREMENT - THE KINETIC ENERGY CORRECTION AND A NEW VISCOMETER
    CANNON, MR
    MANNING, RE
    BELL, JD
    ANALYTICAL CHEMISTRY, 1960, 32 (03) : 355 - 358
  • [34] MEASUREMENT OF VISCOSITY OF BIOLOGIC FLUIDS BYCONE PLATE VISCOMETER
    WELLS, RE
    MERRILL, EW
    DENTON, R
    JOURNAL OF LABORATORY AND CLINICAL MEDICINE, 1961, 57 (04): : 646 - &
  • [35] EFFECT OF SHEAR TEMPERATURE ON VISCOSITY IN A ROTATIONAL VISCOMETER MEASUREMENT
    WELTMANN, RN
    KUHNS, PW
    JOURNAL OF COLLOID SCIENCE, 1952, 7 (03): : 218 - 226
  • [36] Experimental study on factors affecting the end effect in gas viscosity measurement using capillary-tube viscometer
    Fang, Xin
    Yue, Xiang'an
    Fu, Joseph Y.
    An, Weiqing
    Zou, Jirui
    Feng, Xuegang
    Tian, Wenhao
    An, Weijie
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (07):
  • [37] Development of a Simple Droplet-Based Microfluidic Capillary Viscometer for Low-Viscosity Newtonian Fluids
    DeLaMarre, Michael F.
    Keyzer, Alec
    Shippy, Scott A.
    ANALYTICAL CHEMISTRY, 2015, 87 (09) : 4649 - 4657
  • [38] Blood viscosity measurements using a pressure-scanning capillary viscometer
    Sehyun Shin
    Do-Young Keum
    Yun Hee Ku
    KSME International Journal, 2002, 16 : 1719 - 1724
  • [39] Reducing measurement uncertainty of a high pressure capillary viscometer
    Senkung der Messunsicherheit eines Hochdruck-Kapillarviskosimeters
    Boese, Norbert, 1995, Vincentz Verlag, Hannover, Germany (05):
  • [40] Blood viscosity measurements using a pressure-scanning capillary viscometer
    Shin, S
    Keum, DY
    Ku, YH
    KSME INTERNATIONAL JOURNAL, 2002, 16 (12): : 1719 - 1724