Feasibility of Intraoperative Three-Dimensional Transesophageal Echocardiography in the Evaluation of Right Ventricular Volumes and Function in Patients Undergoing Cardiac Surgery

被引:41
作者
Fusini, Laura [1 ,3 ]
Tamborini, Gloria [1 ]
Gripari, Paola [1 ]
Maffessanti, Francesco [3 ]
Mazzanti, Valeria [1 ]
Muratori, Manuela [1 ]
Salvi, Luca [1 ]
Sisillo, Erminio [1 ]
Caiani, Enrico G. [3 ]
Alamanni, Francesco [1 ,2 ]
Fiorentini, Cesare [1 ,2 ]
Pepi, Mauro [1 ]
机构
[1] IRCCS, Ctr Cardiol Monzino, I-20138 Milan, Italy
[2] Univ Milan, Dept Cardiovasc Sci, Milan, Italy
[3] Politecn Milan, Dept Biomed Engn, I-20133 Milan, Italy
关键词
Right ventricle; Three-dimensional transesophageal echocardiography; Cardiac Surgery; EJECTION FRACTION; CARDIOVASCULAR-DISEASE; SYSTOLIC FUNCTION; ANNULAR VELOCITY; ADULT PATIENTS; VALVE DISEASE; HEART; DYSFUNCTION; FAILURE; ASSOCIATION;
D O I
10.1016/j.echo.2011.05.002
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The aim of this study was to test the feasibility of the assessment of right ventricular (RV) volumes and function using real-time three-dimensional (3D) transesophageal echocardiographic (TEE) imaging in patients undergoing cardiac surgery. Methods: One hundred-fifty surgical patients were enrolled: 65 undergoing mitral valve repair, 10 undergoing mitral valve and tricuspid valve repair, four with congenital heart disease, two undergoing Jarvik implantation, 13 undergoing aortic valve surgical replacement, and 56 undergoing transcatheter aortic valve implantation. Real-time 3D TEE acquisition for RV evaluation was performed before and after the surgical procedure and compared with standard two-dimensional multiplane TEE measurements. In a subgroup of 81 patients, 3D transthoracic echocardiographic imaging was also performed. RV volumetric quantification was performed for all data using dedicated software. Results: Three-dimensional RV analysis was feasible in 98.7% in the preoperative TEE data set and in 92.7% in the postoperative TEE data set. Agreement between 3D transthoracic and transesophageal echocardiography for end-diastolic volume (r = 0.98; 95% confidence interval [CI], -0.2 +/- 13.6 mL), end-systolic volume (r = 0.97; 95% CI, -2.1 +/- 10.2 mL), ejection fraction (r = 0.77; 95% CI, 1.8 +/- 8.2%), and stroke volume (r = 0.91; 95% CI, 2.0 +/- 12.9 mL) was significant. RV parameters were highly reproducible in patients with both normal and dilated RV volumes. Conclusions: Intraoperative 3D TEE assessment of RV volumes and function is feasible in patients with normal and dilated right ventricles, with good correlation between 3D transthoracic echocardiographic and TEE RV parameters. These measurements could improve the quantitative evaluation of RV function during cardiac surgery. (J Am Soc Echocardiogr 2011; 24: 868-77.)
引用
收藏
页码:868 / 877
页数:10
相关论文
共 32 条
[1]   Real-time transesophageal three-dimensional echocardiography for guidance of percutaneous cardiac interventions:: first experience [J].
Balzer, Jan ;
Kuehl, Harald ;
Rassaf, Tienush ;
Hoffmann, Rainer ;
Schauerte, Patrick ;
Kelm, Malte ;
Franke, Andreas .
CLINICAL RESEARCH IN CARDIOLOGY, 2008, 97 (09) :565-574
[2]   Role of real-time 3-dimensional transesophageal echocardiography in transcatheter aortic valve implantation [J].
Bouzas-Mosquera, Alberto ;
Alvarez-Garcia, Nemesio ;
Ortiz-Vazquez, Eduardo ;
Cuenca-Castillo, Jose J. .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2009, 35 (05) :909-909
[3]   ACC/AHA/ASE 2003 guideline update for the clinical application of echocardiography: Summary article - A report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines (ACC/AHA/ASE committee to update the 1997 guidelines for the clinical application of echocardiography) [J].
Cheitlin, MD ;
Armstrong, WF ;
Aurigemma, GP ;
Beller, GA ;
Bierman, FZ ;
Davis, JL ;
Douglas, PS ;
Faxon, DP ;
Gillam, LD ;
Kimball, TR ;
Kussmaul, WG ;
Pearlman, AS ;
Philbrick, JT ;
Rakowski, H ;
Thys, DM ;
Antman, EM ;
Smith, SC ;
Alpert, JS ;
Gregoratos, G ;
Anderson, JL ;
Hiratzka, LF ;
Faxon, DP ;
Hunt, SA ;
Fuster, V ;
Jacobs, AK ;
Gibbons, RJ ;
Russell, RO .
CIRCULATION, 2003, 108 (09) :1146-1162
[4]   Usefulness of tricuspid annular velocity in identifying global RV dysfunction in patients with primary pulmonary hypertension: A comparison with 3D echo-derived right ventricular ejection fraction [J].
De Castro, Stefano ;
Cavarretta, Elena ;
Milan, Alberto ;
Caselli, Stefano ;
Di Angelantonio, Emanuele ;
Carmine, Dario Vizza ;
Lucchetti, Diego ;
Patel, Ayan ;
Kuvin, Jeffrey ;
Pandian, Natesa G. .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2008, 25 (03) :289-293
[5]   Intraoperative assessment of right ventricular volume and function [J].
De Simone, R ;
Wolf, I ;
Mottl-Link, S ;
Böttiger, BW ;
Rauch, H ;
Meinzer, HP ;
Hagl, S .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (06) :988-993
[6]   Independent and additive prognostic value of right ventricular systolic function and pulmonary artery pressure in patients with chronic heart failure [J].
Ghio, S ;
Gavazzi, A ;
Campana, C ;
Inserra, C ;
Klersy, C ;
Sebastiani, R ;
Arbustini, E ;
Recusani, F ;
Tavazzi, L .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) :183-188
[7]   Normal values of right ventricular size and function by real-time 3-dimensional echocardiography: Comparison with cardiac magnetic resonance imaging [J].
Gopal, Aasha S. ;
Chukwu, Ebere O. ;
Iwuchukwu, Chizor J. ;
Katz, Alan S. ;
Toole, Rena S. ;
Schapiro, William ;
Reichek, Nathaniel .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2007, 20 (05) :445-455
[8]   Three-Dimensional Echocardiographic Assessment of Right Ventricular Volume and Function in Adult Patients With Congenital Heart Disease: Comparison With Magnetic Resonance Imaging [J].
Grewal, Jasmine ;
Majdalany, David ;
Syed, Imran ;
Pellikka, Patricia ;
Warnes, Carole A. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2010, 23 (02) :127-133
[9]   Real-Time Three-Dimensional Transesophageal Echocardiography in the Intraoperative Assessment of Mitral Valve Disease [J].
Grewal, Jasmine ;
Mankad, Sunil ;
Freeman, William K. ;
Click, Roger L. ;
Suri, Rakesh M. ;
Abel, Martin D. ;
Oh, Jae K. ;
Pellikka, Patricia A. ;
Nesbitt, Gillian C. ;
Syed, Imran ;
Mulvagh, Sharon L. ;
Miller, Fletcher A. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2009, 22 (01) :34-41
[10]   Real-time three-dimensional transoesophageal echocardiography: a new intraoperative feasible and useful technology in cardiac surgery [J].
Gripari, Paola ;
Tamborini, Gloria ;
Barbier, Paolo ;
Maltagliati, Anna C. ;
Galli, Claudia A. ;
Muratori, Manuela ;
Salvi, Luca ;
Sisillo, Erminio ;
Alamanni, Francesco ;
Pepi, Mauro .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2010, 26 (06) :651-660