摘要
Automatic retinal image analysis is emerging as an important screening tool for early detection of eye diseases. Glaucoma is one of the most common causes of blindness. The manual examination of optic disk (OD) is a standard procedure used for detecting glaucoma. In this paper, we present an automatic OD parameterization technique based on segmented OD and cup regions obtained from monocular retinal images. A novel OD segmentation method is proposed which integrates the local image information around each point of interest in multidimensional feature space to provide robustness against variations found in and around the OD region. We also propose a novel cup segmentation method which is based on anatomical evidence such as vessel bends at the cup boundary, considered relevant by glaucoma experts. Bends in a vessel are robustly detected using a region of support concept, which automatically selects the right scale for analysis. A multi-stage strategy is employed to derive a reliable subset of vessel bends called r-bends followed by a local spline fitting to derive the desired cup boundary. The method has been evaluated on 138 images comprising 33 normal and 105 glaucomatous images against three glaucoma experts. The obtained segmentation results show consistency in handling various geometric and photometric variations found across the dataset. The estimation error of the method for vertical cup-to-disk diameter ratio is 0.09/0.08 (mean/standard deviation) while for cup-to-disk area ratio it is 0.12/0.10. Overall, the obtained qualitative and quantitative results show effectiveness in both segmentation and subsequent OD parameterization for glaucoma assessment.
引用
收藏
页码:1192 / 1205
页数:14
相关论文
共 51 条
  • [41] Integrated active contours for texture segmentation
    Sagiv, Chen
    Sochen, Nir A.
    Zeevi, Yehoshua Y.
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2006, 15 (06) : 1633 - 1646
  • [42] Schmid C, 2001, PROC CVPR IEEE, P39
  • [43] SCREENING FOR DIABETIC-RETINOPATHY
    SINGER, DE
    NATHAN, DM
    FOGEL, HA
    SCHACHAT, AP
    [J]. ANNALS OF INTERNAL MEDICINE, 1992, 116 (08) : 660 - 671
  • [44] Spaeth George L, 2002, Trans Am Ophthalmol Soc, V100, P181
  • [45] Stapor K, 2004, LECT NOTES COMPUT SC, V3039, P41
  • [46] Tang YD, 2006, INT C PATT RECOG, P183
  • [47] Active contours driven by local Gaussian distribution fitting energy
    Wang, Li
    He, Lei
    Mishra, Arabinda
    Li, Chunming
    [J]. SIGNAL PROCESSING, 2009, 89 (12) : 2435 - 2447
  • [48] *WHO, 1997, WHO PROGR PREV BLIND
  • [49] LEVEL-SET BASED AUTOMATIC CUP-TO-DISC RATIO DETERMINATION USING RETINAL FUNDUS IMAGES IN ARGALI
    Wong, D. W. K.
    Liu, J.
    Lim, J. H.
    Jia, X.
    Yin, F.
    Li, H.
    Wong, T. Y.
    [J]. 2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8, 2008, : 2266 - +
  • [50] Optic disk feature extraction via modified deformable model technique for glaucoma analysis
    Xu, Juan
    Chutatape, Opas
    Sung, Eric
    Zheng, Ce
    Kuan, Paul Chew Tec
    [J]. PATTERN RECOGNITION, 2007, 40 (07) : 2063 - 2076