Optic Disk and Cup Segmentation From Monocular Color Retinal Images for Glaucoma Assessment

被引:289
作者
Joshi, Gopal Datt [1 ]
Sivaswamy, Jayanthi [1 ]
Krishnadas, S. R. [2 ]
机构
[1] IIIT Hyderabad, Ctr Visual Informat Technol, Hyderabad 500032, Andhra Pradesh, India
[2] Aravind Eye Hosp, Madurai 625020, Tamil Nadu, India
关键词
Active contour; cup; cup-to-disk ratio (CDR); glaucoma; neuroretinal rim; optic disk (OD); retinal images; segmentation; vessel bend; ACTIVE CONTOURS; FEATURE-EXTRACTION; REGION;
D O I
10.1109/TMI.2011.2106509
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Automatic retinal image analysis is emerging as an important screening tool for early detection of eye diseases. Glaucoma is one of the most common causes of blindness. The manual examination of optic disk (OD) is a standard procedure used for detecting glaucoma. In this paper, we present an automatic OD parameterization technique based on segmented OD and cup regions obtained from monocular retinal images. A novel OD segmentation method is proposed which integrates the local image information around each point of interest in multidimensional feature space to provide robustness against variations found in and around the OD region. We also propose a novel cup segmentation method which is based on anatomical evidence such as vessel bends at the cup boundary, considered relevant by glaucoma experts. Bends in a vessel are robustly detected using a region of support concept, which automatically selects the right scale for analysis. A multi-stage strategy is employed to derive a reliable subset of vessel bends called r-bends followed by a local spline fitting to derive the desired cup boundary. The method has been evaluated on 138 images comprising 33 normal and 105 glaucomatous images against three glaucoma experts. The obtained segmentation results show consistency in handling various geometric and photometric variations found across the dataset. The estimation error of the method for vertical cup-to-disk diameter ratio is 0.09/0.08 (mean/standard deviation) while for cup-to-disk area ratio it is 0.12/0.10. Overall, the obtained qualitative and quantitative results show effectiveness in both segmentation and subsequent OD parameterization for glaucoma assessment.
引用
收藏
页码:1192 / 1205
页数:14
相关论文
共 51 条
  • [1] Abdel-Ghafar RA, 2007, MED INFORM INTERNET, V32, P19, DOI 10.1080/14639230601095865
  • [2] ABRMOFF MD, 2007, INVEST OPHTHALMOL, V48, P1665
  • [3] [Anonymous], P MED IM 2009 COMP A
  • [4] Bock R, 2007, LECT NOTES COMPUT SC, V4713, P355
  • [5] Glaucoma risk index: Automated glaucoma detection from color fundus images
    Bock, Ruediger
    Meier, Joerg
    Nyul, Laszlo G.
    Hornegger, Joachim
    Michelson, Georg
    [J]. MEDICAL IMAGE ANALYSIS, 2010, 14 (03) : 471 - 481
  • [6] Active contours without edges for vector-valued images
    Chan, TE
    Sandberg, BY
    Vese, LA
    [J]. JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2000, 11 (02) : 130 - 141
  • [7] Active contours without edges
    Chan, TF
    Vese, LA
    [J]. IEEE TRANSACTIONS ON IMAGE PROCESSING, 2001, 10 (02) : 266 - 277
  • [8] Chrastek R., 2002, Bildverarbeitung fur die Medizin 2002, P263
  • [9] Digital stereo image analyzer for generating automated 3-D measures of optic disc deformation in glaucoma
    Corona, E
    Mitra, S
    Wilson, M
    Krile, T
    Kwon, YH
    Soliz, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2002, 21 (10) : 1244 - 1253
  • [10] USE OF HOUGH TRANSFORMATION TO DETECT LINES AND CURVES IN PICTURES
    DUDA, RO
    HART, PE
    [J]. COMMUNICATIONS OF THE ACM, 1972, 15 (01) : 11 - &