Importance of core joints in GIC/dc studies with scaled down laboratory transformers

被引:5
作者
Borrill, Leslie D. [1 ]
Chisepo, Hilary K. [2 ]
Gaunt, C. T. [2 ]
机构
[1] Eskom Holdings SOC, Koeberg Nucl Power Stn, Cape Town, South Africa
[2] Univ Cape Town, Dept Elect Engn, Cape Town, South Africa
关键词
Core joints; Equivalent circuit; FEM; Saturation; Stray flux; Transformer inductance; MODEL;
D O I
10.1016/j.ijepes.2020.105974
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The response of large power transformers to geomagnetically induced currents (GICs) cannot be tested fully in factories because of the significant reactive power required. While carrying out physical tests on scaled-down models of a power transformer, we discovered that models with high-grade electrical core steel and even a transformer tank, as widely used in investigating the bias effects of GICs and leakage dc, cannot replicate adequately the actual performance if they are built without relevant construction details. Laboratory testing and FEM simulation of three single-phase four-limb transformers show that transformer models need multi-step lap mitered joints similar to those in full-scale power transformers to reproduce correctly the saturation response to dc components. FEM simulation also shows the change of transformer inductance when driven into deep saturation, as required in equivalent circuit models. The approach of achieving consistency between equivalent circuit, FEM and physical models even in the presence of saturable core joints is a novel contribution which provides guidance for future research in slow transient phenomenon studies.
引用
收藏
页数:7
相关论文
共 29 条
[11]   Measurements show need for transformer core joint details in finite element modelling of GIC and DC effects [J].
Chisepo, Hilary Kudzai ;
Borrill, Leslie David ;
Gaunt, Charles Trevor .
COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2018, 37 (03) :1011-1028
[12]  
Chisepo HK, 2019, P 13 IEEE POWERTECH
[13]   Accurate Measurement of the Air-Core Inductance of Iron-Core Transformers With a Non-Ideal Low-Power Rectifier [J].
de Leon, Francisco ;
Jazebi, Saeed ;
Farazmand, Ashkan .
IEEE TRANSACTIONS ON POWER DELIVERY, 2014, 29 (01) :294-296
[14]   Transformer failures in regions incorrectly considered to have low GIC-risk [J].
Gaunt, C. T. ;
Coetzee, G. .
2007 IEEE LAUSANNE POWERTECH, VOLS 1-5, 2007, :807-+
[15]  
Ilo A., 2000, ICEM 2000 Proceedings. International Conference on Electrical Machines, P252
[16]  
Jazebi S, 2016, IEEE T POWER DELIVER, P1
[17]   Experimentally Validated Reversible Single-Phase Multiwinding Transformer Model for the Accurate Calculation of Low-Frequency Transients [J].
Jazebi, Saeed ;
de Leon, Francisco .
IEEE TRANSACTIONS ON POWER DELIVERY, 2015, 30 (01) :193-201
[18]   Dual Reversible Transformer Model for the Calculation of Low-Frequency Transients [J].
Jazebi, Saeed ;
de Leon, Francisco ;
Farazmand, Ashkan ;
Deswal, Digvijay .
IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (04) :2509-2517
[19]   GIC occurrences and GIC test for 400 kV system transformer [J].
Lahtinen, M ;
Elovaara, J .
IEEE TRANSACTIONS ON POWER DELIVERY, 2002, 17 (02) :555-561
[20]   Simulation of Transformer Hotspot Heating due to Geomagnetically Induced Currents [J].
Marti, Luis ;
Rezaei-Zare, Afshin ;
Narang, Arun .
IEEE TRANSACTIONS ON POWER DELIVERY, 2013, 28 (01) :320-327