Protoporphyrin IX dimethyl ester as active material in PVC matrix membranes for the fabrication of zinc(II) selective sensor

被引:45
作者
Gupta, VK [1 ]
Kumar, A [1 ]
Mangla, R [1 ]
机构
[1] Univ Roorkee, Dept Chem, Roorkee 247667, Uttar Pradesh, India
关键词
Zn2+-selective electrodes; sensors; potentiometric sensors;
D O I
10.1016/S0925-4005(01)00656-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
PVC based membrane containing dimethyl-8,13-divinyl-3,7,12,17-tetramethyl-21H, 23H-porphine-2,18-dipropionate (Protoporphyrin IX dimethyl ester (I)) as active material along with sodium tetraphenyl berate (NaTPB) as anion excluder, and dioctyl phthalate (DOP) as solvent mediator in the ratio 15:100:2:200 (w/w) (I:DOP:NaTPB:PVC) exhibited a working concentration range of 1.5 x 10(-5) to 1.0 x 10(-1) M, with the slope of 29.0 +/- 1.0 mV/decade of activity and a fast response time (10 s). The working pH range of the sensor is 2.1-4.0 and it could be successfully used in partially non-aqueous medium (up to 40% v/v). The sensor has a life time of more than 5 months. It exhibits good selectivity over a number of cations and has been used as an indicator electrode for the end point determination in the potentiometric titration of Zn2+ against EDTA. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:617 / 623
页数:7
相关论文
共 24 条
[1]  
BOUEN S, 1982, J CHEM SOC CHEM COMM, P1172
[2]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[3]   DETERMINATION OF SELECTIVITY COEFFICIENTS OF ION-SELECTIVE ELECTRODES BY A MATCHED-POTENTIAL METHOD [J].
GADZEKPO, VPY ;
CHRISTIAN, GD .
ANALYTICA CHIMICA ACTA, 1984, 164 (OCT) :279-282
[4]  
Gokel G.W., 1991, CROWN ETHERS CRYPTAN
[5]   ZINC-SENSITIVE POLYMERIC MEMBRANE ELECTRODE [J].
GORTON, L ;
FIEDLER, U .
ANALYTICA CHIMICA ACTA, 1977, 90 (MAY) :233-236
[6]  
Gupta VK, 1999, ELECTROANAL, V11, P573, DOI 10.1002/(SICI)1521-4109(199906)11:8<573::AID-ELAN573>3.3.CO
[7]  
2-Q
[8]   PVC-based neutral carrier and organic exchanger membranes as sensors for the determination of Ba2+ and Sr2+ [J].
Gupta, VK ;
Jain, AK ;
Khurana, U ;
Singh, LP .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (2-3) :201-211
[9]   A PVC-based 12-crown-4 membrane potentiometric sensor for zinc (II) ions [J].
Gupta, VK .
SENSORS AND ACTUATORS B-CHEMICAL, 1999, 55 (2-3) :195-200
[10]   Cadmium(II)-selective sensors based on dibenzo-24-crown-8 in PVC matrix [J].
Gupta, VK ;
Kumar, P .
ANALYTICA CHIMICA ACTA, 1999, 389 (1-3) :205-212