Determination of acibenzolar-S-methyl and its acidic metabolite in soils by HPLC-diode array detection

被引:8
|
作者
Myresiotis, Charalampos K. [1 ]
Papadakis, Emmanouil N.
Vryzas, Zisis G. [2 ]
Papadopoulou-Mourkidou, Euphemia
机构
[1] Aristotle Univ Thessaloniki, Pesticide Sci Lab, Fac Agr, Thessaloniki 54124, Greece
[2] Democritus Univ Thrace, Lab Agr Pharmacol & Ecotoxicol, Orestias, Greece
关键词
acibenzolar-S-methyl; systemic acquired resistance (SAR); plant activator; soil; pesticides; HPLC-UV; extraction; SYSTEMIC ACQUIRED-RESISTANCE; BACTERIAL SPOT; EXTRACTION; INDUCTION; PRODUCTS; TOMATO; PLANTS;
D O I
10.1080/03601234.2011.583881
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A simple and accurate method for the analysis of acibenzolar-S-methyl (benzo[1,2,3] thiadiazole-7-carbothioic acid-S-methyl ester; CGA 245 704; ASM) and its major conversion product, benzo[1,2,3] thiadiazole-7-carboxylic acid (CGA 210 007; BTC), in soils is presented. ASM extraction from soil samples was performed using acetonitrile and BTC was extracted with a mixture of potassium phosphate buffer (0.5 M, pH 3) and acetonitrile (70: 30 %, v/v). Both extracts were directly analyzed in a high-performance liquid chromatography-diode array detection (HPLC-DAD) system. Pesticide separation was achieved on a C18 (4.6 mm x 150 mm, 5 mu m) analytical column with a isocratic elution of acetonitrile: water 40:60 % (v/v) with 0.6 mL L-1 acetic acid at a flow rate of 1 mL min(-1). Linear regression coefficients (r(2)) of the external calibration curves were always above 0.9997. The limits of detection (LOD) and quantification (LOQ) of the method were 0.005 and 0.02 mg Kg(-1) for ASM, and 0.01 and 0.05 mg Kg(-1) for BTC, respectively. Recoveries were investigated at six fortification levels and were in the range of 90-120 % for ASM and 74-96 % for BTC with relative standard deviations (RSDs) below 11% in all cases. The method was also validated by analyzing freshly spiked soil samples with 2.7% organic matter content at 0.5 mg Kg(-1) level, with slightly lower recovery values only for ASM. Moreover, recoveries for intermediate aged residues of the analytes were similar to fresh residues. This method was also applied to determine ASM half-life (t(1/2) = 8.7 h) and the rate of the acidic metabolite formation.
引用
收藏
页码:550 / 556
页数:7
相关论文
共 50 条
  • [1] Determination of acibenzolar-S-methyl and its degradation product in agricultural products by HPLC
    Takatsuki, S
    Nemoto, S
    Tsutsumi, T
    Sasaki, K
    Toyoda, M
    JOURNAL OF THE FOOD HYGIENIC SOCIETY OF JAPAN, 2000, 41 (06): : 381 - 386
  • [2] Determination of isoflavones in the aerial part of red clover by HPLC-diode array detection
    Gikas, Evagelos
    Alesta, Alexandra
    Economou, Garifalia
    Karamanos, Andreas
    Tsarbopoulos, Anthony
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2008, 31 (08) : 1181 - 1194
  • [3] Electrochemical study of the fungicide acibenzolar-s-methyl and its voltammetric determination in environmental samples
    Guziejewski, Dariusz
    Brycht, Mariola
    Nosal-Wiercinska, Agnieszka
    Smarzewska, Sylwia
    Ciesielski, Witold
    Skrzypek, Slawomira
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART B-PESTICIDES FOOD CONTAMINANTS AND AGRICULTURAL WASTES, 2014, 49 (08) : 550 - 556
  • [4] Identification of organic colourants in cosmetics by HPLC-diode array detection
    S. C. Rastogi
    V. J. Barwick
    S. V. Carter
    Chromatographia, 1997, 45 : 215 - 228
  • [5] A non-extracting procedure for the determination of meloxicam in plasma samples by HPLC-diode array detection
    Medvedovici, A
    Albu, F
    Georgita, C
    Mircioiu, C
    David, V
    ARZNEIMITTELFORSCHUNG-DRUG RESEARCH, 2005, 55 (06): : 326 - 331
  • [6] Development and optimization of the SPE procedure for determination of pharmaceuticals in water samples by HPLC-diode array detection
    Pavlovic, Dragana Mutavdzic
    Babic, Sandra
    Dolar, Davor
    Asperger, Danijela
    Kosutic, Kresimir
    Horvat, Alka J. M.
    Kastelan-Macan, Marija
    JOURNAL OF SEPARATION SCIENCE, 2010, 33 (02) : 258 - 267
  • [7] In vitro inhibition of shikimate hydroxycinnamoyltransferase by acibenzolar acid, the first metabolite of the plant defence inducer acibenzolar-S-methyl
    Negrel, Jonathan
    Klinguer, Agnes
    Adrian, Marielle
    PLANT PHYSIOLOGY AND BIOCHEMISTRY, 2021, 163 : 119 - 127
  • [8] Determination of vaidecoxib in serum using a HPLC-diode array detector and its application in a pharmacokinetic study
    Keshetty, S
    Venisetty, RK
    Molmoori, V
    Ciddi, V
    PHARMAZIE, 2006, 61 (03): : 245 - 246
  • [9] Residue analysis and dietary exposure risk assessment of acibenzolar-S-methyl and its metabolite acibenzolar acid in potato, garlic, cabbage, grape and tomato
    Sun, Hezhi
    Luo, Fengjian
    Zhang, Xinzhong
    Zhou, Li
    Lou, Zhengyun
    Chen, Zongmao
    ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2021, 207
  • [10] Effect of acibenzolar-S-methyl phototransformation on its elicitation activity in tobacco cells
    Lavergne, Florent
    Richard, Claire
    Saudreau, Marc
    Venisse, Jean-Stephane
    Fumanal, Boris
    Goupil, Pascale
    PLANT PHYSIOLOGY AND BIOCHEMISTRY, 2017, 118 : 370 - 376