Supercapacitor energy storage system for fault ride-through of a DFIG wind generation system

被引:93
作者
Rahim, A. H. M. A. [1 ]
Nowicki, E. P. [2 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Elect Engn, Dhahran 31261, Saudi Arabia
[2] Univ Calgary, Dept Elect & Comp Engn, Calgary, AB, Canada
关键词
Wind energy system; DFIG; Supercapacitor energy storage; STATCOM; Wind energy grid integration; FED INDUCTION GENERATORS; ENHANCEMENT; FARMS; INTEGRATION; TURBINES; STATCOM;
D O I
10.1016/j.enconman.2012.03.003
中图分类号
O414.1 [热力学];
学科分类号
摘要
The doubly fed induction generators (DFIGs) are preferred over other variable speed generators because of their advantages in terms of economy and control. One of the problems associated with high wind power penetration DFIG systems, however, is the inability of their converters to work properly under extreme low voltage conditions. This article presents a decoupled P-Q control strategy of a supercapacitor energy storage system, interfaced through a STATCOM, for low voltage ride through as well as damping enhancement of the DFIG system. The STATCOM meets the reactive power need under the depressed voltage condition, while the supercapacitor caters to the real power unbalance. An extensive dynamic model of the DFIG system including a supercapacitor DC-DC buck-boost converter and the STATCOM circuit has been developed. The fault ride-thorough capability of the generator has been investigated for a severe symmetrical three-phase to ground fault on the grid bus. Simulation results suggest that the proposed decoupled control of the supercapacitor STATCOM control strategy can help the DFIG ride through extreme low voltage conditions for significant duration. The proposed control strategy also damps the electromechanical transients, and thus quickly restores normal operation of the converters. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:96 / 102
页数:7
相关论文
共 25 条
  • [1] Akhmatov V., 2005, INDUCTION GENERATORS
  • [2] Coordinated reactive power management in power networks with wind turbines and FACTS devices
    Amaris, Hortensia
    Alonso, Monica
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2011, 52 (07) : 2575 - 2586
  • [3] [Anonymous], IEEE INT S IND EL IS
  • [4] Design and new control of DC/DC converters to share energy between supercapacitors and batteries in hybrid vehicles
    Camara, Mamadou Baeilo
    Gualous, Hamid
    Gustin, Frederic
    Berthon, Alain
    [J]. IEEE TRANSACTIONS ON VEHICULAR TECHNOLOGY, 2008, 57 (05) : 2721 - 2735
  • [5] Power smoothing in wind generation systems using a sensorless vector controlled induction machine driving a flywheel
    Cárdenas, R
    Peña, R
    Asher, G
    Clare, J
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (01) : 206 - 216
  • [6] Power flow control and damping enhancement of a large wind farm using a superconducting magnetic energy storage unit
    Chen, S. -S.
    Wang, L.
    Lee, W-J.
    Chen, Z.
    [J]. IET RENEWABLE POWER GENERATION, 2009, 3 (01) : 23 - 38
  • [7] Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems
    Gautam, Durga
    Vittal, Vijay
    Harbour, Terry
    [J]. IEEE TRANSACTIONS ON POWER SYSTEMS, 2009, 24 (03) : 1426 - 1434
  • [8] Heier S., 2007, Grid Integration of Wind Energy Conversion Systems, V2nd
  • [9] Dynamic Modeling and Improved Control of DFIG Under Distorted Grid Voltage Conditions
    Hu, Jiabing
    Nian, Heng
    Xu, Hailiang
    He, Yikang
    [J]. IEEE TRANSACTIONS ON ENERGY CONVERSION, 2011, 26 (01) : 163 - 175
  • [10] Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid Faults
    Lima, Francisco K. A.
    Luna, Alvaro
    Rodriguez, Pedro
    Watanabe, Edson H.
    Blaabjerg, Frede
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2010, 25 (01) : 118 - 130