MDCT evaluation of aortic root and aortic valve prior to TAVI. What is the optimal imaging time point in the cardiac cycle?

被引:50
作者
Jurencak, Tomas [1 ]
Turek, Jakub [1 ]
Kietselaer, Bastiaan L. J. H. [1 ,2 ,3 ]
Mihl, Casper [1 ,2 ]
Kok, Madeleine [1 ,2 ]
van Ommen, Vincent G. V. A. [3 ]
van Garsse, Leen A. F. M. [4 ]
Nijssen, Estelle C. [1 ]
Wildberger, Joachim E. [1 ,2 ]
Das, Marco [1 ,2 ]
机构
[1] Maastricht Univ, Med Ctr, Dept Radiol, NL-6202 AZ Maastricht, Netherlands
[2] Maastricht Univ, Med Ctr, CARIM Sch Cardiovasc Dis, NL-6202 AZ Maastricht, Netherlands
[3] Maastricht Univ, Med Ctr, Dept Cardiol, NL-6202 AZ Maastricht, Netherlands
[4] Maastricht Univ, Med Ctr, Dept Cardiothorac Surg, NL-6202 AZ Maastricht, Netherlands
关键词
Aortic valve; Aortic valve stenosis; Multidetector computed tomography; Cardiac gated imaging technique; Heart valve prosthesis implantation; MULTIDETECTOR COMPUTED-TOMOGRAPHY; PARAVALVULAR REGURGITATION; TRANSCATHETER; IMPLANTATION; REPLACEMENT; ANNULUS; STENOSIS; PROSTHESIS; DIASTOLE; SYSTOLE;
D O I
10.1007/s00330-015-3607-5
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To determine the optimal imaging time point for transcatheter aortic valve implantation (TAVI) therapy planning by comprehensive evaluation of the aortic root. Multidetector-row CT (MDCT) examination with retrospective ECG gating was retrospectively performed in 64 consecutive patients referred for pre-TAVI assessment. Eighteen different parameters of the aortic root were evaluated at 11 different time points in the cardiac cycle. Time points at which maximal (or minimal) sizes were determined, and dimension differences to other time points were evaluated. Theoretical prosthesis sizing based on different measurements was compared. Largest dimensions were found between 10 and 20 % of the cardiac cycle for annular short diameter (10 %); mean diameter (10 %); effective diameter and circumference-derived diameter (20 %); distance from the annulus to right coronary artery ostium (10 %); aortic root at the left coronary artery level (20 %); aortic root at the widest portion of coronary sinuses (20 %); and right leaflet length (20 %). Prosthesis size selection differed depending on the chosen measurements in 25-75 % of cases. Significant changes in anatomical structures of the aortic root during the cardiac cycle are crucial for TAVI planning. Imaging in systole is mandatory to obtain maximal dimensions. aEuro cent Most aortic root structures undergo significant dimensional changes throughout the cardiac cycle. aEuro cent The largest dimensions of aortic parameters should be determined to optimize TAVI. aEuro cent Circumference-derived diameter showed maximum dimension at 20 % of the cardiac cycle.
引用
收藏
页码:1975 / 1983
页数:9
相关论文
共 37 条
[1]   SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) [J].
Achenbach, Stephan ;
Delgado, Victoria ;
Hausleiter, Joerg ;
Schoenhagen, Paul ;
Min, James K. ;
Leipsic, Jonathon A. .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (06) :366-380
[2]   Feasibility of C-arm computed tomography for transcatheter aortic valve replacement planning [J].
Azzalini, Lorenzo ;
Sharma, Umesh C. ;
Ghoshhajra, Brian B. ;
Elmariah, Sammy ;
Inglessis, Ignacio ;
Palacios, Igor F. ;
Abbara, Suhny .
JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2014, 8 (01) :33-43
[3]   High-pitch dual-source CT angiography of the whole aorta without ECG synchronisation: Initial experience [J].
Beeres, Martin ;
Schell, Boris ;
Mastragelopoulos, Aristidis ;
Herrmann, Eva ;
Kerl, Josef Matthias ;
Gruber-Rouh, Tatjana ;
Lee, Clara ;
Siebenhandl, Petra ;
Bodelle, Boris ;
Zangos, Stephan ;
Vogl, Thomas J. ;
Jacobi, Volkmar ;
Bauer, Ralf W. .
EUROPEAN RADIOLOGY, 2012, 22 (01) :129-137
[4]   Aortic annulus dimension assessment by computed tomography for transcatheter aortic valve implantation: differences between systole and diastole [J].
Bertaso, Angela G. ;
Wong, Dennis T. L. ;
Liew, Gary Y. H. ;
Cunnington, Michael S. ;
Richardson, James D. ;
Thomson, Viji S. ;
Lorraine, Brett ;
Kourlis, George ;
Leech, Diana ;
Worthley, Matthew I. ;
Worthley, Stephen G. .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08) :2091-2098
[5]   Combined Assessment of Aortic Root Anatomy and Aortoiliac Vasculature With Dual-Source CT as a Screening Tool in Patients Evaluated for Transcatheter Aortic Valve Implantation [J].
Blanke, Philipp ;
Euringer, Wulf ;
Baumann, Tobias ;
Reinoehl, Jochen ;
Schlensak, Christian ;
Langer, Mathias ;
Pache, Gregor .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 195 (04) :872-881
[6]   Computed tomography-based evaluation of aortic annulus, prosthesis size and impact on early residual aortic regurgitation after transcatheter aortic valve implantation [J].
Buzzatti, Nicola ;
Maisano, Francesco ;
Latib, Azeem ;
Cioni, Micaela ;
Taramasso, Maurizio ;
Mussardo, Marco ;
Colombo, Antonio ;
Alfieri, Ottavio .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2013, 43 (01) :43-51
[7]   Aortic root rupture during trans-catheter aortic valve implantation [J].
Colli, Andrea ;
Fernandez Nofrerias, Eduardo ;
Escudero, Adria .
EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2011, 39 (05) :788-788
[8]   Early experience with percutaneous transcatheter implantation of heart valve prosthesis for the treatment of end-stage inoperable patients with calcific aortic stenosis [J].
Cribier, A ;
Eltchaninoff, H ;
Tron, C ;
Bauer, F ;
Agatiello, C ;
Sebagh, L ;
Bash, A ;
Nusimovici, D ;
Litzler, PY ;
Bessou, JP ;
Leon, MB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (04) :698-703
[9]   Pulsatile Distention of the Nondiseased and Stenotic Aortic Valve Annulus: Analysis With Electrocardiogram-Gated Computed Tomography [J].
de Heer, Linda M. ;
Budde, Ricardo P. J. ;
van Prehn, Joffrey ;
Mali, Willem P. Th M. ;
Bartels, Lambertus W. ;
Stella, Pieter R. ;
van Herwerden, Lex A. ;
Kluin, Jolanda ;
Vincken, Koen L. .
ANNALS OF THORACIC SURGERY, 2012, 93 (02) :516-522
[10]   Aortic root dimension changes during systole and diastole: evaluation with ECG-gated multidetector row computed tomography [J].
de Heer, Linda M. ;
Budde, Ricardo P. J. ;
Mali, Willem P. Th. M. ;
de Vos, Alexander M. ;
van Herwerden, Lex A. ;
Kluin, Jolanda .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2011, 27 (08) :1195-1204