Improving hyperthermia treatment planning for the pelvis by accurate fluid modeling

被引:17
|
作者
Schooneveldt, G. [1 ]
Kok, H. P. [1 ]
Balidemaj, E. [1 ]
Geijsen, E. D. [1 ]
van Ommen, F. [1 ]
Sijbrands, J. [1 ]
Bakker, A. [1 ]
de la Rosette, J. J. M. C. H. [2 ]
Hulshof, M. C. C. M. [1 ]
de Reijke, T. M. [2 ]
Crezee, J. [1 ]
机构
[1] Acad Med Ctr, Dept Radiotherapy, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
[2] Acad Med Ctr, Dept Urol, Meibergdreef 9, NL-1105 AZ Amsterdam, Netherlands
关键词
hyperthermia; treatment planning; bladder cancer; fluid modeling; INVASIVE BLADDER-CANCER; TRANSITIONAL-CELL CARCINOMA; MITOMYCIN-C; REGIONAL HYPERTHERMIA; CLINICAL-TRIAL; CERVICAL-CARCINOMA; WALL THICKNESS; PHASED-ARRAY; TEMPERATURE; FEASIBILITY;
D O I
10.1118/1.4961741
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Hyperthermia is an established (neo) adjuvant treatment modality for a number of pelvic malignancies. Optimal treatment of these tumors requires robust treatment planning, but up until now, the urinary bladder was not modeled accurately, making current simulations less reliable. The authors improved the dielectric and thermophysical model of the urinary bladder in their treatment planning system, and showed the improvements using phantom experiments. Methods: The authors suspended a porcine bladder in muscle tissue equivalent gel and filled it with 120 ml 0.9% saline. The authors heated the phantom during 15 min with their deep hyperthermia device, using clinical settings, and measured the temperature both inside and outside the bladder. The authors simulated the experiment, both using the clinically used treatment planning system, and using the improved model featuring correct dielectric properties for the bladder content and an enhanced thermophysical model, enabling the simulation of convection. Results: Although the dielectric changes have an impact throughout the phantom, the dominant effect is a higher net heat absorption in the bladder. The effects of changing the thermophysical model are limited to the bladder and its surroundings, but result in a very different temperature profile. The temperatures predicted by the simulations using the new bladder model were in much better agreement with the measurements than those predicted by currently used treatment planning system. Conclusions: Modeling convection in the urinary bladder is very important for accurate hyperthermia treatment planning in the pelvic area. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:5442 / 5452
页数:11
相关论文
共 50 条
  • [21] Hyperthermia treatment planning: clinical application and ongoing research
    Kok, H. P.
    Crezee, J.
    2020 14TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP 2020), 2020,
  • [22] Clinical evaluation and verification of the hyperthermia treatment planning system HyperPlan
    Gellermann, J
    Wust, P
    Stalling, D
    Seebass, M
    Nadobny, J
    Beck, R
    Hege, HC
    Deuflhard, P
    Felix, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2000, 47 (04): : 1145 - 1156
  • [23] Benefits of superficial hyperthermia treatment planning: Five case studies
    De Bruijne, M.
    Wielheesen, D. H. M.
    Van der Zee, J.
    Chavannes, N.
    Van Rhoon, G. C.
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2007, 23 (05) : 417 - 429
  • [24] Numerical Model for Magnetic Fluid Hyperthermia in a Realistic Breast Phantom: Calorimetric Calibration and Treatment Planning
    Miaskowski, Arkadiusz
    Subramanian, Mahendran
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2019, 20 (18)
  • [25] A Refined Eigenvalue-Based Optimization Technique for Hyperthermia Treatment Planning
    Mestrom, R. M. C.
    van Engelen, J. P.
    van Beurden, M. C.
    Paulides, M. M.
    Numan, W. C. M.
    Tijhuis, A. G.
    2014 8TH EUROPEAN CONFERENCE ON ANTENNAS AND PROPAGATION (EUCAP), 2014, : 2010 - 2013
  • [26] Modelling Curved Contact Flexible Microstrip Applicators for Patient-Specific Superficial Hyperthermia Treatment Planning
    Kok, H. Petra
    Groen, Jort
    Bakker, Akke
    Crezee, Johannes
    CANCERS, 2020, 12 (03)
  • [27] The hot-to-cold spot quotient for SAR-based treatment planning in deep microwave hyperthermia
    Zanoli, Massimiliano
    Trefna, Hana Dobsicek
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2022, 39 (01) : 1421 - 1439
  • [28] Assessment of the thermal tissue models for the head and neck hyperthermia treatment planning
    Drizdal, Tomas
    van Rhoon, Gerard C.
    Fiser, Ondrej
    Vrba, David
    van Holthe, Netteke
    Vrba, Jan
    Paulides, Margarethus M.
    JOURNAL OF THERMAL BIOLOGY, 2023, 115
  • [29] Permittivity and Conductivity Estimation for Hyperthermia Treatment Planning
    Bevacqua, Martina T.
    Bellizzi, Gennaro G.
    Crocco, Lorenzo
    Isernia, Tommaso
    2018 IEEE ANTENNAS AND PROPAGATION SOCIETY INTERNATIONAL SYMPOSIUM ON ANTENNAS AND PROPAGATION & USNC/URSI NATIONAL RADIO SCIENCE MEETING, 2018, : 591 - 592
  • [30] Optimization techniques for hyperthermia treatment planning of breast cancer: A comparative study
    Baskaran, Divya
    Arunachalam, Kavitha
    2019 IEEE MTT-S INTERNATIONAL MICROWAVE AND RF CONFERENCE (IMARC), 2019,