Worldwide Randomized Antibiotic EnveloPe Infection PrevenTion Trial (WRAP-IT)

被引:52
作者
Tarakji, Khaldoun G. [1 ]
Mittal, Suneet [2 ]
Kennergren, Charles [3 ]
Corey, Ralph [4 ]
Poole, Jeanne [5 ]
Stromberg, Kurt [6 ]
Lexcen, Daniel R. [6 ]
Wilkoff, Bruce L. [1 ]
机构
[1] Cleveland Clin, Sect Electrophysiol & Pacing, Cleveland, OH 44106 USA
[2] Arrhythmia Inst Valley Hlth Syst, New York, NY USA
[3] Sahlgrens Univ Hosp, Dept Cardiothorac Surg, Gothenburg, Sweden
[4] Duke Univ, Duke Clin Res Inst, Durham, NC USA
[5] Univ Washington, Div Cardiol, Seattle, WA 98195 USA
[6] Medtronic, Plc Mounds View, MN USA
关键词
ELECTRONIC DEVICE INFECTIONS; IMPLANTABLE CARDIOVERTER-DEFIBRILLATORS; PERMANENT PACEMAKER IMPLANTATION; RISK-FACTORS; ANTIBACTERIAL ENVELOPE; HEART-ASSOCIATION; UNITED-STATES; MANAGEMENT; MORTALITY; RATES;
D O I
10.1016/j.ahj.2016.06.010
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Cardiac implantable electronic device (CIED) infection is a major complication that is associated with significant morbidity and mortality. The aim of this study is to determine whether Medtronic TYRX absorbable envelope reduces the risk of CIED infection through 12 months of follow-up post procedure. Methods WRAP-IT is a randomized, prospective, multi center, international, single-blinded study. Up to 7,764 subjects who are undergoing CIED generator replacement, upgrade, or revision, or a de novo CRT-D implant, will be enrolled and randomized (1:1) to receive the TYRX envelope or not. The primary endpoint is major CIED infection throughout 12 months of follow up after the procedure. Data will be analyzed with an intention to treat approach. WRAP-IT will also assess the performance of Medtronic's lead monitoring algorithms in subjects whose CIED includes a transvenous right ventricular defibrillation system. Conclusions WRAP-IT is a large randomized clinical trial that will assess the efficacy of TYRX absorbable envelope in reducing CIED infection, define its cost effectiveness, and will also provide a unique opportunity to better understand the pathophysiology and risk factors for CIED infection.
引用
收藏
页码:12 / 21
页数:10
相关论文
共 42 条
[1]   Clinical Characteristics and Outcome of Infective Endocarditis Involving Implantable Cardiac Devices [J].
Athan, Eugene ;
Chu, Vivian H. ;
Tattevin, Pierre ;
Selton-Suty, Christine ;
Jones, Phillip ;
Naber, Christoph ;
Miro, Jose M. ;
Ninot, Salvador ;
Fernandez-Hidalgo, Nuria ;
Durante-Mangoni, Emanuele ;
Spelman, Denis ;
Hoen, Bruno ;
Lejko-Zupanc, Tatjana ;
Cecchi, Enrico ;
Thuny, Franck ;
Hannan, Margaret M. ;
Pappas, Paul ;
Henry, Margaret ;
Fowler, Vance G., Jr. ;
Crowley, Anna Lisa ;
Wang, Andrew .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2012, 307 (16) :1727-1735
[2]   Update on Cardiovascular Implantable Electronic Device Infections and Their Management A Scientific Statement From the American Heart Association [J].
Baddour, Larry M. ;
Epstein, Andrew E. ;
Erickson, Christopher C. ;
Knight, Bradley P. ;
Levison, Matthew E. ;
Lockhart, Peter B. ;
Masoudi, Frederick A. ;
Okum, Eric J. ;
Wilson, Walter R. ;
Beerman, Lee B. ;
Bolger, Ann F. ;
Estes, N. A. Mark, III ;
Gewitz, Michael ;
Newburger, Jane W. ;
Schron, Eleanor B. ;
Taubert, Kathryn A. .
CIRCULATION, 2010, 121 (03) :458-477
[3]   Risk Factors for Mortality in Patients With Cardiac Device-Related Infection [J].
Baman, Timir S. ;
Gupta, Sanjaya K. ;
Valle, Javier A. ;
Yamada, Elina .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (02) :129-134
[4]   Implantation Success and Infection in Cardiovascular Implantable Electronic Device Procedures Utilizing an Antibacterial Envelope [J].
Bloom, Heather L. ;
Constantin, Luis ;
Dan, Daniel ;
de Lurgio, David B. ;
El-Chami, Mikhail ;
Ganz, Leonard I. ;
Gleed, Kent J. ;
Hackett, F. Kevin ;
Kanuru, Narendra K. ;
Lerner, Daniel J. ;
Rasekh, Abdi ;
Simons, Grant R. ;
Sogade, Felix O. ;
Sohail, Muhammad R. .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2011, 34 (02) :133-142
[5]  
Bonow RO, 2008, J AM COLL CARDIOL, V52, pE1, DOI [10.1016/j.jacc.2008.02.032, 10.1016/j.jacc.2008.05.007, 10.1016/j.hrthm.2008.04.014]
[6]   Increasing rates of cardiac device infections among Medicare beneficiaries: 1990-1999 [J].
Cabell, CH ;
Heidenreich, PA ;
Chu, VH ;
Moore, CM ;
Stryjewski, ME ;
Corey, GR ;
Fowler, VG .
AMERICAN HEART JOURNAL, 2004, 147 (04) :582-586
[7]   Antibiotic prophylaxis for permanent pacemaker implantation - A meta-analysis [J].
Da Costa, A ;
Kirkorian, G ;
Cucherat, M ;
Delahaye, F ;
Chevalier, P ;
Cerisier, A ;
Isaaz, K ;
Touboul, P .
CIRCULATION, 1998, 97 (18) :1796-1801
[8]   Cardiac device infections are associated with a significant mortality risk [J].
de Bie, Mihaly K. ;
van Rees, Johannes B. ;
Thijssen, J. ;
Borleffs, C. Jan Willem ;
Trines, Serge A. ;
Cannegieter, Suzanne C. ;
Schalij, Martin J. ;
van Erven, Lieselot .
HEART RHYTHM, 2012, 9 (04) :494-498
[9]   Efficacy of Antibiotic Prophylaxis Before the Implantation of Pacemakers and Cardioverter-Defibrillators Results of a Large, Prospective, Randomized, Double-Blinded, Placebo-Controlled Trial [J].
de Oliveira, Julio Cesar ;
Martinelli, Martino ;
D'Orio Nishioka, Silvana Angelina ;
Varejao, Tania ;
Uipe, David ;
Andrade Pedrosa, Anisio Alexandre ;
Costa, Roberto ;
Danik, Stephan B. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2009, 2 (01) :29-34
[10]   Detection and management of an implantable cardioverter defibrillator lead failure - Incidence and clinical implications [J].
Ellenbogen, KA ;
Wood, MA ;
Shepard, RK ;
Clemo, HF ;
Vaughn, T ;
Holloman, K ;
Dow, M ;
Leffler, J ;
Abeyratne, A ;
Verness, D .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2003, 41 (01) :73-80