Real-Time Monitoring of Tissue Displacement and Temperature Changes during MR-Guided High Intensity Focused Ultrasound

被引:28
作者
Bour, Pierre [1 ,2 ,3 ,4 ]
Marquet, Fabrice [1 ,2 ,3 ]
Ozenne, Valery [1 ,2 ,3 ]
Toupin, Solenn [1 ,2 ,3 ,5 ]
Dumont, Erik [4 ]
Aubry, Jean-Francois [6 ]
Lepetit-Coiffe, Matthieu [5 ]
Quesson, Bruno [1 ,2 ,3 ]
机构
[1] Fdn Bordeaux Univ, Electrophysiol & Heart Modeling Inst, IHU Liryc, Pessac, France
[2] Univ Bordeaux, Ctr Rech Cardiothorac Bordeaux, U1045, Bordeaux, France
[3] INSERM, Ctr Rech Cardiothorac Bordeaux, U1045, Bordeaux, France
[4] Image Guided Therapy SA, Pessac, France
[5] Siemens Healthineers France, St Denis, Reunion, France
[6] ESPCI ParisTech, INSERM U979, CNRS UMR 7587, Inst Langevin, Paris, France
关键词
MRgHIFU; ARFI; thermometry; ablation; LESION FORMATION; CLINICAL-APPLICATIONS; SONICATION; ABLATION; FEASIBILITY; MRGHIFU; HMIFU; HIFU;
D O I
10.1002/mrm.26588
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The therapy endpoint most commonly used in MR-guided high intensity focused ultrasound is the thermal dose. Although namely correlated with nonviable tissue, it does not account for changes in mechanical properties of tissue during ablation. This study presents a new acquisition sequence for multislice, subsecond and simultaneous imaging of tissue temperature and displacement during ablation. Methods: A single-shot echo planar imaging sequence was implemented using a pair of motion-encoding gradients, with alternated polarities. A first ultrasound pulse was synchronized on the second lobe of the motion-encoding gradients and followed by continuous sonication to induce a local temperature increase in ex vivo muscle and in vivo on pig liver. Lastly, the method was evaluated in the brain of two volunteers to assess method's precision. Results: For thermal doses higher than the lethal threshold, displacement amplitude was reduced by 21% and 28% at the focal point in muscle and liver, respectively. Displacement value remained nearly constant for nonlethal thermal doses values. The mean standard deviation of temperature and displacement in the brain of volunteers remained below 0.8 degrees C and 2.5 mm. Conclusion: This new fast imaging sequence provides realtime measurement of temperature distribution and displacement at the focus during HIFU ablation. (C) 2017 International Society for Magnetic Resonance in Medicine.
引用
收藏
页码:1911 / 1921
页数:11
相关论文
共 35 条
[1]   Monitoring of Thermal Therapy Based on Shear Modulus Changes: II. Shear Wave Imaging of Thermal Lesions [J].
Arnal, Bastien ;
Pernot, Mathieu ;
Tanter, Mickael .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (08) :1603-1611
[2]   ARFI-prepared MRgHIFU in liver: Simultaneous mapping of ARFI-displacement and temperature elevation, using a fast GRE-EPI sequence [J].
Auboiroux, Vincent ;
Viallon, Magalie ;
Roland, Joerg ;
Hyacinthe, Jean-Noel ;
Petrusca, Lorena ;
Morel, Denis R. ;
Goget, Thomas ;
Terraz, Sylvain ;
Gross, Patrick ;
Becker, Christoph D. ;
Salomir, Rares .
MAGNETIC RESONANCE IN MEDICINE, 2012, 68 (03) :932-946
[3]   NEUROPHYSIOLOGIC CORRELATES OF SONICATION TREATMENT IN PATIENTS WITH ESSENTIAL TREMOR [J].
Chang, Jin Woo ;
Min, Byoung-Kyong ;
Kim, Bong-Soo ;
Chang, Won Seok ;
Lee, Yong-Ho .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (01) :124-131
[4]   Temperature rise recorded during lesion formation by high-intensity focused ultrasound [J].
Clarke, RL ;
terHaar, GR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1997, 23 (02) :299-306
[5]  
Coluccial D, 2014, J THER ULTRASOUND, V2, DOI [10.1186/2050-5736-217, 10.1186/2050-5736-2-17]
[6]   Dependence of ultrasonic attenuation and absorption in dog soft tissues on temperature and thermal dose [J].
Damianou, CA ;
Sanghvi, NT ;
Fry, FJ ;
MaassMoreno, R .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1997, 102 (01) :628-634
[7]   Real-time adaptive methods for treatment of mobile organs by MRI-controlled high-intensity focused ultrasound [J].
de Senneville, Baudouin Denis ;
Mougenot, Charles ;
Moonen, Chrit T. W. .
MAGNETIC RESONANCE IN MEDICINE, 2007, 57 (02) :319-330
[8]  
DEPOORTER J, 1995, MAGN RESON MED, V34, P359, DOI 10.1002/mrm.1910340313
[9]   ARRHENIUS RELATIONSHIPS FROM THE MOLECULE AND CELL TO THE CLINIC [J].
DEWEY, WC .
INTERNATIONAL JOURNAL OF HYPERTHERMIA, 1994, 10 (04) :457-483
[10]   Fast magnetic-resonance temperature imaging [J].
deZwart, JA ;
vanGelderen, P ;
Kelly, DJ ;
Moonen, CTW .
JOURNAL OF MAGNETIC RESONANCE SERIES B, 1996, 112 (01) :86-90