Integrated chip set for a pulsed time-of-flight laser radar

被引:2
作者
Kostamovaara, J [1 ]
Mäntyniemi, A [1 ]
Palojärvi, P [1 ]
Peltola, T [1 ]
Ruotsalainen, T [1 ]
Räisänen-Ruotsalainen, E [1 ]
机构
[1] Univ Oulu, Dept Elect Engn, Infotech Oulu, FIN-90014 Oulu, Finland
来源
TESTING RELIABILITY AND APPLICATIONS OF OPTOELECTRONIC DEVICES | 2001年 / 4285卷
关键词
laser radar; pulsed time-of-flight techniques; timing discrimination; time interval measurement; time-to-digital conversion;
D O I
10.1117/12.426895
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The pulsed time-of-flight laser range finding techniques based on laser diode transmitter enables one to realize a mm-level accuracy to non-cooperative targets in a distance measurement range of several tens of meters in industrial applications such as the measurement of level heights in silos, positioning of tools and vehicles, velocity measurement, anti-collision radars, proximity sensors, etc. In this work the basic pulsed time-of-flight laser radar functions, the receiver channel and the time interval measurement unit, have been realized in the form of high-performance full-custom integrated circuits, which should pave the way for realizing a laser radar eventually as a component-like micro system thus increasing the number of possible applications for the developed techniques. The integrated BiCMOS receiver channel produces a logic level output pulse for the time interval measurement from the received laser echo. Two versions were realized, one detecting the leading edge of the received pulse and achieving an accuracy of +/-35mm in a dynamic range of 1:4000. In the other version gain control and constant fraction type of timing detection techniques are used to enhance the accuracy. With this circuit an input dynamic range of 1:650 (SNR > 10) can be achieved with a timing accuracy of about +/-3mm. The developed fully integrated CMOS time-to-digital converter realization is based on a counter and a novel parallel two-step interpolation method. The single-shot precision and measurement range of the unit are 50ps and 2 mus, respectively. In averaging mode the linearity is better than +/-5ps. Even better single-shot precision can be realized with analog interpolation techniques, however, at the expense of reduced stability.
引用
收藏
页码:33 / 47
页数:15
相关论文
共 18 条
  • [1] Optical distance meter using a pulsed laser diode and fast avalanche photo diodes for measurements of molten steel levels
    Araki, T
    Yoshida, H
    [J]. JOURNAL OF DYNAMIC SYSTEMS MEASUREMENT AND CONTROL-TRANSACTIONS OF THE ASME, 1996, 118 (04): : 800 - 803
  • [2] Bertolini G., 1968, SEMICONDUCTOR DETECT
  • [3] CHERRY M, 1963, P I ELECTR ENG, V110, P375
  • [4] *HEWL PACK, HEWL PACK
  • [5] Jelalian A.V., 1992, LASER RADAR SYSTEMS
  • [6] KAISTO I, 1993, P SOC PHOTO-OPT INS, V208, P121
  • [7] Timing discriminator for pulsed time-of-flight laser rangefinding measurements
    Kilpela, A
    Ylitalo, J
    Maatta, K
    Kostamovaara, J
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1998, 69 (05) : 1978 - 1984
  • [8] KOSTAMOVAARA J, 1992, P SOC PHOTO-OPT INS, V1633, P114, DOI 10.1117/12.59211
  • [9] Profiling of hot surfaces by pulsed time-of-flight laser range finder techniques
    Määttä, Kari
    Kostamovaara, Juha
    Myllylä, Risto
    [J]. Applied Optics, 1993, 32 (27) : 5334 - 5347
  • [10] An integrated digital CMOS time-to-digital converter with sub-gate-delay resolution
    Mäntyniemi, A
    Rahkonen, T
    Kostamovaara, J
    [J]. ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2000, 22 (01) : 61 - 70