Relationship of Central Corneal Thickness with Optic Disc Parameters: The Singapore Malay Eye Study

被引:19
|
作者
Wu, Ren-Yi [1 ,2 ]
Zheng, Ying-Feng [1 ,2 ]
Wong, Tien-Yin [1 ,2 ,3 ]
Cheung, Carol Yim-Lui [1 ,2 ]
Loon, Seng-Chee [4 ]
Chauhan, Balwantray C. [5 ]
Aung, Tin [1 ,2 ,3 ]
机构
[1] Singapore Natl Eye Ctr, Singapore 168751, Singapore
[2] Singapore Eye Res Inst, Singapore, Singapore
[3] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117595, Singapore
[4] Natl Univ Hlth Syst, Singapore, Singapore
[5] Dalhousie Univ, Dept Ophthalmol & Visual Sci, Halifax, NS, Canada
基金
加拿大健康研究院; 英国医学研究理事会;
关键词
INTRAOCULAR-PRESSURE; GLAUCOMA; POPULATION; PREVALENCE; HYSTERESIS; PEOPLE;
D O I
10.1167/iovs.10-6038
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To examine the relationship of central corneal thickness (CCT) with optic disc parameters measured by confocal scanning laser ophthalmoloscopy in a Malay population. METHODS. This was a population-based cross-sectional study of Asian Malay adults aged 40-80 years living in Singapore. Participants had a standardized interview, examination, and imaging at a study clinic. CCT was measured with an ultrasound pachymeter. Confocal scanning laser imaging was performed on all participants to obtain optic disc parameters. Multivariate regression analyses controlling for age, sex, intraocular pressure, and other potentially confounding factors were conducted separately for disc area, rim area, cup-to-disc ratio, and mean cup depth. RESULTS. Of the 3280 participants in the study, 2525 (77.0%) right eyes with reliable confocal scanning laser tomography images were included in this analysis, with 48 eyes defined to have primary open-angle glaucoma (POAG). In POAG subjects, CCT was positively correlated with rim area (regression coefficient of 0.372 mm(2) per 100 mu m CCT increase; P = 0.035) and negatively correlated with cup-to-disc area ratio (-0.160 per 100 mu m CCT increase; P = 0.024). There was no relationship between CCT and disc size (P = 0.088). In the 2468 subjects without glaucoma, there were no associations between CCT and confocal scanning laser tomography parameters. CONCLUSIONS. In this population-based study, decreased CCT was associated with lower rim area and greater cup-to-disc area in subjects with POAG, but not in subjects without glaucoma. (Invest Ophthalmol Vis Set. 201152:1320-1324) DOI: 10.1167/iovs.10-6038
引用
收藏
页码:1320 / 1324
页数:5
相关论文
共 50 条
  • [1] Central Corneal Thickness and its Associations With Ocular and Systemic Factors: The Singapore Malay Eye Study
    Su, Daniel H. W.
    Wong, Tien Y.
    Foster, Paul J.
    Tay, Wan-Ting
    Saw, Seang-Mei
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2009, 147 (04) : 709 - 716
  • [2] Influence of Refractive Error on Optic Disc Topographic Parameters: The Singapore Malay Eye Study
    Wu, Ren-Yi
    Wong, Tien-Yin
    Zheng, Ying-Feng
    Cheung, Carol Yim-Lui
    Perera, Shamira A.
    Saw, Seang Mei
    Aung, Tin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2011, 152 (01) : 81 - 86
  • [3] Effect of Corneal Arcus on Central Corneal Thickness, Intraocular Pressure, and Primary Open-angle Glaucoma The Singapore Malay Eye Study
    Wu, Renyi
    Wong, Tien-Yin
    Saw, Seang-Mei
    Cajucom-Uy, Howard
    Rosman, Mohamad
    Aung, Tin
    ARCHIVES OF OPHTHALMOLOGY, 2010, 128 (11) : 1455 - 1461
  • [4] The relationship between central corneal thickness and the optic disc in an elderly population: the Bridlington Eye Assessment Project
    Hawker, M. J.
    Edmunds, M. R.
    Vernon, S. A.
    Hillman, J. G.
    MacNab, H. K.
    EYE, 2009, 23 (01) : 56 - 62
  • [5] The relationship between central corneal thickness and the optic disc in an elderly population: the Bridlington Eye Assessment Project
    M J Hawker
    M R Edmunds
    S A Vernon
    J G Hillman
    H K MacNab
    Eye, 2009, 23 : 56 - 62
  • [6] Cardiovascular Risk Factors, Inflammation, and Corneal Arcus: The Singapore Malay Eye Study
    Wu, Reny
    Wang, Jie Jin
    Tai, E. Shyong
    Wong, Tien Yin
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2010, 150 (04) : 581 - 587
  • [7] Chronic Kidney Disease and Intraocular Pressure The Singapore Malay Eye Study
    Nongpiur, Monisha E.
    Wong, Tien Y.
    Sabanayagam, Charumathi
    Lim, Su-Chi
    Tai, E-Shyong
    Aung, Tin
    OPHTHALMOLOGY, 2010, 117 (03) : 477 - 483
  • [8] Relationship between corneal thickness and optic disc damage in glaucoma
    Hewitt, AW
    Cooper, RL
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2005, 33 (02) : 158 - 163
  • [9] Myopia and Cognitive Dysfunction: The Singapore Malay Eye Study
    Ong, Shin-Yeu
    Ikram, M. Kamran
    Haaland, Benjamin Adam
    Cheng, Ching-Yu
    Saw, Seang-Mei
    Wong, Tien Yin
    Cheung, Carol Y.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (01) : 799 - 803
  • [10] Distribution of Ocular Perfusion Pressure and Its Relationship with Open-Angle Glaucoma: The Singapore Malay Eye Study
    Zheng, Yingfeng
    Wong, Tien Y.
    Mitchell, Paul
    Friedman, David S.
    He, Mingguang
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (07) : 3399 - 3404