Development of an electrochemical assay for 2,6-dinitrotoluene, based on a screen-printed carbon electrode, and its potential application in bioanalysis, occupational and public health

被引:32
作者
Honeychurch, KC [1 ]
Hart, JP [1 ]
Pritchard, PRJ [1 ]
Hawkins, SJ [1 ]
Ratcliffe, NM [1 ]
机构
[1] Univ W England, Fac Sci Appl, Ctr Res Analyt Mat & Sensors Sci, Bristol BS16 1QY, Avon, England
关键词
2,6-dinitrotoluene; screen-printed carbon electrodes; stripping voltammetry; bio-analysis; occupational/public health;
D O I
10.1016/S0956-5663(03)00208-2
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Screen-printed carbon electrodes (SPCEs) have been successfully exploited as disposable sensors for the measurement of 2,6-dinitrotoluene (2,6-DNT) using a stripping voltammetric method. Initial investigations were undertaken using cyclic voltammetry (CV) to characterise the redox behaviour at the SPCEs. Further studies were then performed to deduce the optimum applied potential and accumulation time for the stripping voltammetric procedure. In addition, a study was carried out to ascertain whether small volumes of samples could be reliably used for analysis. From these studies it was shown that a 100 mul aliquot of sample could be analysed and the calibration plot was linear from 161 ng ml(-1) to 137 mug ml(-1) (R-2 = 0.9991), the former concentration being the detection limit. The effects of the major components of human saliva at concentrations normally present were investigated. Of the individual components tested, only Cl- and albumen were found to interfere. The presence of the latter could be easily overcome by the addition of (NH4)(2)SO4. An interference study was also carried out on some inorganic and organic species that may be present in water samples. The sensors were evaluated by carrying out 2,6-DNT determinations on spiked and unspiked human saliva, dust wipe and potable water samples. Mean recoveries of 47.5, 73.4 and 102.4% were obtained; coefficients of variation of 7.88, 6.63 and 6.42% were calculated for a concentration of 9.1 mug ml(-1) in water, 10.6 mug ml(-1) saliva samples, and 141.1 ng cm(-2) for dust wipe samples, respectively. The performance characteristics show that the method holds promise and reliable data may be obtained for 2,6-DNT in bioanalysis and public health. (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:305 / 312
页数:8
相关论文
共 30 条
  • [1] Voltammetric determination of niclosamide at a glassy carbon electrode
    Alemu, H
    Wagana, P
    Tseki, PF
    [J]. ANALYST, 2002, 127 (01) : 129 - 134
  • [2] Altman P.L, 1968, METABOLISM FEDERATIO
  • [3] VOLTAMMETRIC STUDIES OF A PSYCHOTROPIC-DRUG WITH NITRO-GROUPS - DETERMINATION OF FLUNITRAZEPAM IN URINE USING HMDE
    BERMEJO, E
    ZAPARDIEL, A
    PEREZ, JA
    HUERTA, A
    HERNANDEZ, L
    [J]. TALANTA, 1993, 40 (11) : 1649 - 1656
  • [4] DETERMINATION OF NITRO AROMATIC, NITRAMINE, AND NITRATE ESTER EXPLOSIVE COMPOUNDS IN EXPLOSIVE MIXTURES AND GUNSHOT RESIDUE BY LIQUID-CHROMATOGRAPHY AND REDUCTIVE ELECTROCHEMICAL DETECTION
    BRATIN, K
    KISSINGER, PT
    BRINER, RC
    BRUNTLETT, CS
    [J]. ANALYTICA CHIMICA ACTA, 1981, 130 (02) : 295 - 311
  • [5] CONSIDERATION OF BOTH GENOTOXIC AND NONGENOTOXIC MECHANISMS IN PREDICTING CARCINOGENIC POTENTIAL
    BUTTERWORTH, BE
    [J]. MUTATION RESEARCH, 1990, 239 (02): : 117 - 132
  • [6] BATCH SQUARE-WAVE VOLTAMMETRIC AND FLOW-INJECTION AMPEROMETRIC DETERMINATION OF TRACE AMOUNTS OF BROMOFENOXIM
    CAI, XH
    OGOREVC, B
    BENFENATI, E
    KALCHER, K
    NOVIC, M
    GRABEC, I
    [J]. ANALYTICA CHIMICA ACTA, 1995, 310 (01) : 153 - 160
  • [7] FABRICATION AND CHARACTERIZATION OF A SCREEN-PRINTED, DISPOSABLE, AMPEROMETRIC CHOLESTEROL BIOSENSOR
    GILMARTIN, MAT
    HART, JP
    [J]. ANALYST, 1994, 119 (11) : 2331 - 2336
  • [8] CONCEPTION FOR THE INVESTIGATION OF CONTAMINATED MUNITION PLANTS .2. INVESTIGATION OF FORMER RDX-PLANTS AND FILLING STATIONS
    HAAS, R
    SCHREIBER, I
    VONLOW, E
    STORK, G
    [J]. FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1990, 338 (01): : 41 - 45
  • [9] HARPER HA, 1977, REV PHYSL CHEM, P624
  • [10] Honeychurch KC, 2000, ELECTROANAL, V12, P171, DOI 10.1002/(SICI)1521-4109(200002)12:3<171::AID-ELAN171>3.0.CO