Comparison of reconstruction accuracy and efficiency among autocalibrating data-driven parallel imaging methods

被引:160
作者
Brau, Anja C. S. [1 ]
Beatty, Philip J. [1 ]
Skare, Stefan [2 ]
Bammer, Roland [2 ]
机构
[1] GE Healthcare, Global Appl Sci Lab, Menlo Pk, CA 94025 USA
[2] Stanford Univ, Dept Radiol, Stanford, CA USA
关键词
parallel imaging; autocalibrating; GRAPPA; reconstruction; MRI;
D O I
10.1002/mrm.21481
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The class of autocalibrating "data-driven" parallel imaging (PI) methods has gained attention in recent years due to its ability to achieve high quality reconstructions even under challenging imaging conditions. The aim of this work was to perform a formal comparative study of various data-driven reconstruction techniques to evaluate their relative merits for certain imaging applications. A total of five different reconstruction methods are presented within a consistent theoretical framework and experimentally compared in terms of the specific measures of reconstruction accuracy and efficiency using one-dimensional (1D)-accelerated Cartesian datasets. It is shown that by treating the reconstruction process as two discrete phases, a calibration phase and a synthesis phase, the reconstruction pathway can be tailored to exploit the computational advantages available in certain data domains. A new "split-domain" reconstruction method is presented that performs the calibration phase in k-space (k(x), k(y)) and the synthesis phase in a hybrid (x, k(y)) space, enabling highly accurate 2D neighborhood reconstructions to be performed more efficiently than previously possible with conventional techniques. This analysis may help guide the selection of PI methods for a given imaging task to achieve high reconstruction accuracy at minimal computational expense.
引用
收藏
页码:382 / 395
页数:14
相关论文
共 32 条
[1]  
BALIMER M, 2004, TOP MAGN RESON IMAG, V15, P223
[2]  
BANKSON J, 2001, P 9 ANN M ISMRM HON
[3]  
Beatty P., 2007, P 15 ANN M ISMRM BER, V15, P1749
[4]  
BEATTY PJ, 2006, P 14 ANN M ISMRM SEA
[5]   2D-GRAPPA-operator for faster 3D parallel MRI [J].
Blaimer, Martin ;
Breuer, Felix A. ;
Mueller, Matthias ;
Seiberlich, Nicole ;
Ebel, Dmitry ;
Heidemann, Robin M. ;
Griswold, Mark A. ;
Jakob, Peter M. .
MAGNETIC RESONANCE IN MEDICINE, 2006, 56 (06) :1359-1364
[6]  
BRACEWELL R, 1995, 2 DIMENSIONAL IMAGIG
[7]  
Brau A, 2006, P 14 ANN M ISMRM SEA
[8]   The SENSE ghost: Field-of-view restrictions for SENSE imaging [J].
Goldfarb, JW .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2004, 20 (06) :1046-1051
[9]   Autocalibrated coil sensitivity estimation for parallel imaging [J].
Griswold, MA ;
Breuer, F ;
Blaimer, M ;
Kannengiesser, S ;
Heidemann, RM ;
Mueller, M ;
Nittka, M ;
Jellus, V ;
Kiefer, B ;
Jakob, PM .
NMR IN BIOMEDICINE, 2006, 19 (03) :316-324
[10]   Generalized Autocalibrating Partially Parallel Acquisitions (GRAPPA) [J].
Griswold, MA ;
Jakob, PM ;
Heidemann, RM ;
Nittka, M ;
Jellus, V ;
Wang, JM ;
Kiefer, B ;
Haase, A .
MAGNETIC RESONANCE IN MEDICINE, 2002, 47 (06) :1202-1210