Treatment of periprosthetic femoral fractures with two different minimal invasive angle-stable plates: Biomechanical comparison studies on cadaveric bones

被引:47
作者
Konstantinidis, L. [1 ]
Hauschild, O. [1 ]
Beckmann, N. A. [1 ]
Hirschmueller, A. [1 ]
Suedkamp, N. P. [1 ]
Helwig, P. [1 ]
机构
[1] Univ Freiburg, Dept Orthopaed & Trauma Surg, Med Ctr, D-79106 Freiburg, Germany
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2010年 / 41卷 / 12期
关键词
Periprosthetic fracture; Vancouver classification; Angle plate fixation; Biomechanics; LISS (R) plate; NCB DF (R) plate; STABILIZATION SYSTEM LISS; FEMUR FRACTURES; SHAFT FRACTURES; VANCOUVER TYPE-B1; LOCKING PLATE; FIXATION; HIP; MANAGEMENT;
D O I
10.1016/j.injury.2010.05.007
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction: The introduction of fixed-angle plate osteosynthesis techniques has provided us a further means to treat periprosthetic femoral fractures. The goal of this experimental study is to evaluate the biomechanical properties and stability of treated periprosthetic fractures when using two different plate systems, which vary in the locking mechanism and the screw placement (monocortical or bicortical) with respect to the prosthesis stem. Materials and methods: Using five pairs of formalin-fixed femora, a Vancouver B1 periprosthetic fracture was treated either with a 13-hole LISS (R) titanium plate using four monocortical periprosthetic screws or with a non-contact bridging plate (NCB) DF (R) plate using bicortical angle-stable blocked screws positioned ventrally or dorsally to the prosthesis stem. Bones were loaded under axial and cyclic compression with a progressively increased load until failure. Displacement at the osteotomy gap was measured during loading using an ultra-sound measuring system. Results: The mean displacement in the region of the fracture gap was not significantly different at any time during the experiments for the two models. The mean force resulting in subsequent model failure was similar in both models; the failure morphology varied slightly between the models, however. Four of the five LISS (R) models exhibited either a tear-out of the monocortical screws or a decortication from the bony shaft of the cortical lamella surrounding the screws. On the other side, two of the NCB models showed macroscopically visible fissures along the osteosynthesis plates at the height of the osteotomy gap, and were hence considered implant failures. Only one NCB model showed tear-out of the bicortically placed screws. Conclusion: Bicortical screw placement provides more stable anchoring when compared to monocortical screw fixation. However, in relation to the amount of motion at the osteotomy gap and to failure loads, stabilisation of periprosthetic femoral fractures can be equally well achieved using either the LISS (R) plate with periprosthetic monocortical screws or the NCB plate with poly-axially placed bicortical screws. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1256 / 1261
页数:6
相关论文
共 24 条
[1]   Osteoporotic periprosthetic fractures of the femur in elderly patients: Outcome after fixation with the LISS plate [J].
Anakwe, R. E. ;
Aitken, S. A. ;
Khan, L. A. K. .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2008, 39 (10) :1191-1197
[2]   Hip contact forces and gait patterns from routine activities [J].
Bergmann, G ;
Deuretzbacher, G ;
Heller, M ;
Graichen, F ;
Rohlmann, A ;
Strauss, J ;
Duda, GN .
JOURNAL OF BIOMECHANICS, 2001, 34 (07) :859-871
[3]   Management of periprosthetic fractures - The hip [J].
Berry, DJ .
JOURNAL OF ARTHROPLASTY, 2002, 17 (04) :11-13
[4]   Classification of the hip [J].
Brady, OH ;
Garbuz, DS ;
Masri, BA ;
Duncan, CP .
ORTHOPEDIC CLINICS OF NORTH AMERICA, 1999, 30 (02) :215-+
[5]   Locking compression plate fixation of Vancouver type-b1 periprosthetic femoral fractures [J].
Buttaro, M. A. ;
Farfalli, G. ;
Nunez, M. Paredes ;
Comba, F. ;
Piccaluga, F. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2007, 89A (09) :1964-1969
[6]   Locking plate osteosynthesis for Vancouver Type B1 and Type C periprosthetic fractures of femur: A report on 12 patients [J].
Chakravarthy, Jagannath ;
Bansal, Rajeev ;
Cooper, Julian .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2007, 38 (06) :725-733
[7]   Polymethylmethacrylate augmentation of pedicle screw for osteoporotic spinal surgery [J].
Chang, Ming-Chau ;
Liu, Chien-Lin ;
Chen, Tain-Hsiung .
SPINE, 2008, 33 (10) :E317-E324
[8]   Fixation of periprosthetic femoral shaft fractures: A biomechanical comparison of two techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
Di Cesare, PE .
JOURNAL OF ORTHOPAEDIC TRAUMA, 2001, 15 (03) :177-180
[9]   Fixation of periprosthetic femoral shaft fractures occurring at the tip of the stem - A biomechanical study of 5 techniques [J].
Dennis, MG ;
Simon, JA ;
Kummer, FJ ;
Koval, KJ ;
DiCesare, PE .
JOURNAL OF ARTHROPLASTY, 2000, 15 (04) :523-528
[10]   Treatment of periprosthetic femur fractures with the non-contact bridging plate: a new angular stable implant [J].
Erhardt, J. B. ;
Grob, K. ;
Roderer, G. ;
Hoffmann, A. ;
Forster, T. N. ;
Kuster, M. S. .
ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2008, 128 (04) :409-416