First report for the electrochemical investigation of a new HIV integrase inhibitor dolutegravir: Its voltammetric determination in tablet dosage forms and human urine using a boron-doped diamond electrode

被引:13
作者
Allahverdiyeva, Shabnam [1 ]
Pinar, Pinar Talay [2 ]
Yardim, Yavuz [2 ]
Senturk, Zuhre [3 ]
机构
[1] Van Yuzuncu Yil Univ, Fac Sci, Dept Biochem, TR-65080 Van, Turkey
[2] Van Yuzuncu Yil Univ, Fac Pharm, Dept Analyt Chem, TR-65080 Van, Turkey
[3] Van Yuzuncu Yil Univ, Fac Sci, Dept Analyt Chem, TR-65080 Van, Turkey
关键词
Dolutegravir; Boron-doped diamond electrode; Square-wave adsorptive stripping voltammetry; Tablets; Urine; SIMULTANEOUS QUANTIFICATION; ANTIRETROVIRAL AGENTS; LIQUID-CHROMATOGRAPHY; MS/MS METHOD; DRUG; ELVITEGRAVIR; COBICISTAT; LAMIVUDINE; PLASMA;
D O I
10.1016/j.diamond.2021.108332
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this paper, for the first time, the study of electrochemical investigation and voltammetric determination of HIV integrase inhibitor dolutegravir was described. The effect of pretreatment (anodically or cathodically) of borondoped diamond electrode was investigated in detail on the stripping voltammetric performance for this compound. Dolutegravir presented one or two oxidation peaks within the pH range 2.0-12.0 by using both pretreated electrodes. Employing square-wave stripping mode on the surface of cathodically pretreated boron-doped diamond electrode (after 60 s accumulation at +0.3 V) in Britton-Robinson buffer at pH 10.0, there was a linear dependence of the peak current at +0.79 V (vs. Ag/AgCl, 3 M NaCl) and dolutegravir concentration in the range of 1.0-50.0 mu g mL(-1) (2.38 x 10(-6) -1.19 x 10(-4) M), with a detection limit of 0.26 mu g mL(-1) (6.20 x 10(-7) M). The applicability of the developed approach for the quantification of dolutegravir was tested in the commercial tablet formulations and model human urine samples.
引用
收藏
页数:8
相关论文
共 39 条
[1]   Simultaneous voltammetric determination of vanillin and caffeine in food products using an anodically pretreated boron-doped diamond electrode: Its comparison with HPLC-DAD [J].
Ali, Hoshyar Saadi ;
Abdullah, Abdullah A. ;
Pinar, Pinar Talay ;
Yardim, Yavuz ;
Senturk, Zuhre .
TALANTA, 2017, 170 :384-391
[2]   Electrooxidation of tetracycline antibiotic demeclocycline at unmodified boron-doped diamond electrode and its enhancement determination in surfactant-containing media [J].
Allahverdiyeva, Shabnam ;
Yardim, Yavuz ;
Senturk, Zuhre .
TALANTA, 2021, 223
[3]   Adsorptive stripping voltammetric determination of higenamine on a boron-doped diamond electrode improved by the use of an anionic surfactant [J].
Allahverdiyeva, Shabnam ;
Pinar, Pinar Talay ;
Keskin, Ertugrul ;
Yunusoglu, Oruc ;
Yardim, Yavuz ;
Senturk, Zuhre .
SENSORS AND ACTUATORS B-CHEMICAL, 2020, 303
[4]  
Aristov N., 2015, World Journal of Chemical Education, V3, P119, DOI DOI 10.12691/WJCE-3-5-2
[5]   Recent progress in the applications of boron doped diamond electrodes in electroanalysis of organic compounds and biomolecules - A review [J].
Baluchova, Simona ;
Danhel, Ales ;
Dejmkova, Hana ;
Ostatna, Veronika ;
Fojta, Miroslav ;
Schwarzova-Peckova, Karolina .
ANALYTICA CHIMICA ACTA, 2019, 1077 :30-66
[6]   A sensitive HPLC-MS/MS method for the determination of dolutegravir in human plasma [J].
Bennetto-Hood, Chantelle ;
Tabolt, Glenn ;
Savina, Paul ;
Acosta, Edward P. .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 945 :225-232
[7]   High-Performance Liquid Chromatographic and High-Performance Thin-Layer Chromatographic Method for the Quantitative Estimation of Dolutegravir Sodium in Bulk Drug and Pharmaceutical Dosage Form [J].
Bhavar, Girija B. ;
Pekamwar, Sanjay S. ;
Aher, Kiran B. ;
Thorat, Ravindra S. ;
Chaudhari, Sanjay R. .
SCIENTIA PHARMACEUTICA, 2016, 84 (02) :305-320
[8]   Metabolism, Excretion, and Mass Balance of the HIV-1 Integrase Inhibitor Dolutegravir in Humans [J].
Castellino, Stephen ;
Moss, Lee ;
Wagner, David ;
Borland, Julie ;
Song, Ivy ;
Chen, Shuguang ;
Lou, Yu ;
Min, Sherene S. ;
Goljer, Igor ;
Culp, Amanda ;
Piscitelli, Stephen C. ;
Savina, Paul M. .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 2013, 57 (08) :3536-3546
[9]   Boron-doped diamond-based sensors: A review [J].
Chailapakul, Orawon ;
Siangproh, Weena ;
Tryk, Donald A. .
SENSOR LETTERS, 2006, 4 (02) :99-119
[10]   Development of an HPLC-UV assay method for the simultaneous quantification of nine antiretroviral agents in the plasma of HIV-infected patients [J].
Charbe, Nitin ;
Baldelli, Sara ;
Cozzi, Valeria ;
Castoldi, Simone ;
Cattaneo, Dario ;
Clementi, Emilio .
JOURNAL OF PHARMACEUTICAL ANALYSIS, 2016, 6 (06) :396-403