Comparative evaluation of Scheimpflug tomography parameters between thin non-keratoconic, subclinical keratoconic, and mild keratoconic corneas

被引:48
作者
Huseynli, Samira [1 ]
Salgado-Borges, Jose [2 ,3 ]
Alio, Jorge L. [4 ]
机构
[1] Natl Ophthalmol Ctr, Baku, Azerbaijan
[2] Clin Salgado Borges, Porto, Portugal
[3] Hosp Privado Boa Nova, Porto, Portugal
[4] Univ Miguel Hernandez, Vissum Inst Oftalmol Alicante, Alicante, Spain
关键词
Keratoconus; subclinical keratoconus; corneal pachymetry; post LASIK ectasia; corneal topography; Scheimpflug tomography; Pentacam topography; ELEVATION PARAMETERS; PACHYMETRY; INDEXES; EYES; THICKNESS; ANTERIOR; VOLUME; SHAPE;
D O I
10.1177/1120672118760146
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate and compare the topographic and topometric parameters, thickness profile data, and data from enhanced elevation maps of thin non-keratoconic, subclinical keratoconic, and mild keratoconic corneas with the Pentacam Scheimpflug corneal tomography and to study the usefulness of different parameters to differentiate keratoconus from topographically normal thin corneas. Methods: The study included 30 eyes with subclinical keratoconus, 30 eyes with mild-stage keratoconus, and 54 healthy eyes with minimal pachymetry <= 500 mu m, with a mean age of 21.19 +/- 2.97, 21.75 +/- 1.93, and 21.5 +/- 2.95 years, respectively. The area under the receiver operating characteristic curves was used to analyze the diagnostic significance of the Pentacam parameters. Results: The anterior and posterior corneal elevations, pachymetric progression, the percentage of thickness increase measurements, overall D value, and topometric indices were statistically significantly higher in subclinical and mild keratoconic corneas than in normal eyes with thin cornea (p < 0.05). All these parameters had sufficient strength (area under the receiver operating characteristic curves >0.90) to differentiate clinical keratoconus. Posterior elevation showed the excellent area under the receiver operating characteristic curves with 100% sensitivity and 100% specificity for this purpose. However, among all parameters studied, the anterior elevation (0.935) showed the excellent area under the receiver operating characteristic curves to differentiate subclinical keratoconus, followed by posterior elevation (0.897), index of height decentration (0.887), and D value (0.882). Conclusion: The parameters derived from the Scheimpflug device, such as corneal elevations and overall D value, can effectively differentiate subclinical and clinical keratoconus from non-keratoconic thin cornea eyes. However, the specificity levels of these parameters were relatively limited in the diagnosis of subclinical keratoconus.
引用
收藏
页码:521 / 534
页数:14
相关论文
共 32 条
[1]   Corneal-thickness spatial profile and corneal-volume distribution: Tomographic indices to detect keratoconus [J].
Ambrosio, Renato, Jr. ;
Alonso, Ruiz Simonato ;
Luz, Allan ;
Coca Velarde, Luis Guillermo .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (11) :1851-1859
[2]   Integration of Scheimpflug-Based Corneal Tomography and Biomechanical Assessments for Enhancing Ectasia Detection [J].
Ambrosio, Renato, Jr. ;
Lopes, Bernardo T. ;
Faria-Correia, Fernando ;
Salomao, Marcella Q. ;
Buhren, Jens ;
Roberts, Cynthia J. ;
Elsheikh, Ahmed ;
Vinciguerra, Riccardo ;
Vinciguerra, Paolo .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (07) :434-+
[3]   Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus [J].
Ambrosio, Renato, Jr. ;
Caiado, Ana Laura C. ;
Guerra, Frederico P. ;
Louzada, Ricardo ;
Roy, Abhijit Sinha ;
Luz, Allan ;
Dupps, William J. ;
Belin, Michael W. .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :753-758
[4]   The relationship of Central Corneal Thickness (CCT) to Thinnest Central Cornea (TCC) in healthy adults [J].
Ashwin, Pammal T. ;
Shah, Sunil ;
Pushpoth, Sreekumari ;
Wehbeh, Louai ;
Ilango, Balasubramaniam .
CONTACT LENS & ANTERIOR EYE, 2009, 32 (02) :64-67
[5]   Assessment of Corneal Epithelial Thickness in Asymmetric Keratoconic Eyes and Normal Eyes Using Fourier Domain Optical Coherence Tomography [J].
Catalan, S. ;
Cadarso, L. ;
Esteves, F. ;
Salgado-Borges, J. ;
Lopez, M. ;
Cadarso, C. .
JOURNAL OF OPHTHALMOLOGY, 2016, 2016
[6]   A new approach to keratoconus detection based on corneal morphogeometric analysis [J].
Cavas-Martinez, Francisco ;
Bataille, Laurent ;
Fernandez-Pacheco, Daniel G. ;
Canavate, Francisco J. F. ;
Alio, Jorge L. .
PLOS ONE, 2017, 12 (09)
[7]   COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH [J].
DELONG, ER ;
DELONG, DM ;
CLARKEPEARSON, DI .
BIOMETRICS, 1988, 44 (03) :837-845
[8]   Correlation of basic indicators with stages of keratoconus assessed by Pentacam tomography [J].
Du, Xian-Li ;
Chen, Min ;
Xie, Li-Xin .
INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2015, 8 (06) :1136-1140
[9]   Corneal elevation indices in normal and keratoconic eyes [J].
Fam, Han-Bor ;
Lim, Kooi-Ling .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2006, 32 (08) :1281-1287
[10]   Improved Keratoconus Detection by Ocular Response Analyzer Testing After Consideration of Corneal Thickness as a Confounding Factor [J].
Gaston Galletti, Jeremias ;
Pfoertner, Tomas ;
Fuentes Bonthoux, Fernando .
JOURNAL OF REFRACTIVE SURGERY, 2012, 28 (03) :202-U131