Experimental study of plate type air cooler performances under four operating modes

被引:30
作者
Chen, Yi [1 ]
Yang, Hongxing [1 ]
Luo, Yimo [2 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Renewable Energy Res Grp, Hong Kong, Hong Kong, Peoples R China
[2] Technol & Higher Educ Inst Hong Kong, Fac Sci & Technol, Hong Kong, Hong Kong, Peoples R China
关键词
Experiment; Energy recovery; Heat exchanger; Indirect evaporative cooler; Thermal performance; INDIRECT EVAPORATIVE COOLER; HEAT-EXCHANGERS; COOLING SYSTEM; WET CONDITIONS; FLOW; BUILDINGS; CONDENSATION; FEASIBILITY; MASS; DRY;
D O I
10.1016/j.buildenv.2016.05.022
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
To reduce the chiller energy consumption in a central air-conditioning system, a heat exchanger, acting as an air cooler, can be 'installed before an air handling unit to pre-cool the fresh air by recovering cooling capacity from exhaust air. However, studies on evaluating the performances of air cooler under condensation condition are limited. Therefore, an experimental study was conducted to evaluate the plate type air cooler performance under four operating modes (dry/wet mode, low/high air humidity). Under dry operating mode, the air cooler serves as a traditional air cooler; while under wet operating mode, it works as an indirect evaporative cooler (IEC). The cooler dynamic performances during different operating mode transition were investigated. The steady performances under different parameter influence were also comparatively studied. The results show that wet-operating improves the sensible and latent cooling capacities of air cooler significantly. Condensation takes place under high humidity inlet air, results in decreasing of sensible efficiency but increasing of latent efficiency and total heat transfer rate. The coefficient of performance (COP) of IEC is higher than that of traditional air cooler under the same testing configuration. The highest COP can reach 9.0 and achieved under wet operating mode with condensation. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:296 / 310
页数:15
相关论文
共 43 条
[31]   A review on buildings energy consumption information [J].
Perez-Lombard, Luis ;
Ortiz, Jose ;
Pout, Christine .
ENERGY AND BUILDINGS, 2008, 40 (03) :394-398
[32]   A review of indirect evaporative cooling technology [J].
Porumb, Bogdan ;
Unguresan, Paula ;
Tutunaru, Lucian Fechete ;
Serban, Alexandru ;
Balan, Mugur .
EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 :461-471
[33]   A review of indirect evaporative cooling operating conditions and performances [J].
Porumb, Bogdan ;
Unguresan, Paula ;
Tutunaru, Lucian Fechete ;
Serban, Alexandru ;
Balan, Mugur .
EENVIRO-YRC 2015 - BUCHAREST, 2016, 85 :452-460
[34]  
Qiu G. A, 2007, NOVEL EVAPORATIVE DE
[35]   An analytical model for the heat and mass transfer processes in indirect evaporative cooling with parallel/counter flow configurations [J].
Ren, CQ ;
Yang, HX .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2006, 49 (3-4) :617-627
[36]   Numerical study of a novel, dew point evaporative cooling system [J].
Riangvilaikul, B. ;
Kumar, S. .
ENERGY AND BUILDINGS, 2010, 42 (11) :2241-2250
[37]   An experimental study of a novel dew point evaporative cooling system [J].
Riangvilaikul, B. ;
Kumar, S. .
ENERGY AND BUILDINGS, 2010, 42 (05) :637-644
[38]  
Tulsidasani TR, 1997, INT J ENERG RES, V21, P1099, DOI 10.1002/(SICI)1099-114X(19971010)21:12<1099::AID-ER311>3.3.CO
[39]  
2-J
[40]   Experimental characterisation of an indirect evaporative cooling prototype in two operating modes [J].
Velasco Gomez, Eloy ;
Tejero Gonzalez, Ana ;
Rey Martinez, Francisco Javier .
APPLIED ENERGY, 2012, 97 :340-346