A Systematic Review and Meta-analysis of the Association Between Implantable Cardioverter-Defibrillator Shocks and Long-term Mortality

被引:63
作者
Proietti, Riccardo [1 ,2 ]
Labos, Christopher [1 ]
Davis, Mark [1 ]
Thanassoulis, George [1 ]
Santangeli, Pasquale [3 ]
Russo, Vincenzo [4 ]
Di Biase, Luigi [5 ,6 ]
Roux, Jean-Francois [1 ,7 ]
Verma, Atul [1 ,8 ]
Natale, Andrea [5 ,9 ,10 ,11 ]
Essebag, Vidal [1 ,12 ]
机构
[1] McGill Univ, Ctr Hlth, Montreal, PQ, Canada
[2] Luigi Sacco Hosp, Dept Cardiol, Milan, Italy
[3] Univ Penn, Dept Cardiol, Philadelphia, PA 19104 USA
[4] Monaldi Hosp, Chair Cardiol 2, Naples, Italy
[5] St Davids Med Ctr, Texas Cardiac Arrhythmias Inst, Austin, TX USA
[6] Albert Einstein Coll Med, Montefiore Hosp, New York, NY USA
[7] Univ Sherbrooke, Ctr Hosp, Div Cardiol, Sherbrooke, PQ J1K 2R1, Canada
[8] Southlake Reg Hlth Ctr, Newmarket, ON, Canada
[9] Case Western Reserve Univ, Cleveland, OH 44106 USA
[10] Calif Pacific Med Ctr, EP Serv, San Francisco, CA USA
[11] Scripps Clin, Intervent Electrophysiol, San Diego, CA USA
[12] Hop Sacre Coeur Montreal, Montreal, PQ, Canada
基金
加拿大健康研究院;
关键词
INAPPROPRIATE THERAPY; VENTRICULAR-TACHYCARDIA; ISCHEMIC CARDIOMYOPATHY; MYOCARDIAL-INFARCTION; CATHETER ABLATION; CLINICAL-COURSE; FOLLOW-UP; HIGH-RISK; PREVENTION; APPROPRIATE;
D O I
10.1016/j.cjca.2014.11.023
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is unknown whether implantable cardioverter-defibrillator (ICD) discharges actively contribute to a worse prognosis independent of the underlying arrhythmia. There is considerable variability in the reported risk of mortality after appropriate and inappropriate ICD shocks. The aim of our systematic review was to provide a reliable effect size of the association between ICD shock and mortality for both types of therapies. Methods: On the basis of a systematic literature search, 10 studies were considered eligible for inclusion in the analysis, and data on the hazard ratio (HR) of mortality after ICD shock were extracted from each study. Results: On pooled analysis, a substantial difference was detected in the risk for subsequent mortality between appropriate and inappropriate shocks. Among patients receiving an appropriate ICD shock, the HR for cardiac death was 2.95 (95% confidence interval [CI], 2.12-4.11; P < 0.001) compared with an HR of 1.71 (95% CI, 1.45-2.02) for those receiving an inappropriate shock. Clinical variables like ejection fraction, New York Heart Association class, and length of follow-up did not affect the HRs in our meta-regression models. Conclusions: Our analysis showed a significant association between appropriate and inappropriate ICD shocks and mortality, with a stronger association for appropriate shocks. Previous trials of ICD therapy reduction programming have shown a significant reduction of inappropriate shocks. The management of appropriate shocks is more challenging and may be optimized by the assessment and treatment of the underlying ventricular arrhythmias. The role of therapies aimed at modifying the arrhythmic substrate and the potential impact on ICD shocks and mortality requires further investigation.
引用
收藏
页码:270 / 277
页数:8
相关论文
共 53 条
  • [1] Predictors of Mortality in Patients With an Implantable Cardiac Defibrillator: A Systematic Review and Meta-analysis
    Alba, Ana C.
    Braga, Juarez
    Gewarges, Mena
    Walter, Stephen D.
    Guyatt, Gordon H.
    Ross, Heather J.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2013, 29 (12) : 1729 - 1740
  • [2] The Association Between ICD Interventions and Mortality is Independent of their Modality: Clinical Implications
    Bencardino, Gianluigi
    Di Monaco, Antonio
    Rio, Teresa
    Frontera, Antonio
    Santangeli, Pasquale
    Leo, Milena
    Pelargonio, Gemma
    Perna, Francesco
    Narducci, Maria Lucia
    Gabrielli, Francesca
    Lanza, Gaetano Antonio
    Bellocci, Fulvio
    Rebuzzi, Antonio
    Crea, Filippo
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (12) : 1363 - 1367
  • [3] The prognostic impact of shocks for clinical and induced arrhythmias on morbidity and mortality among patients with implantable cardioverter-defibrillators
    Bhavnani, Sanjeev P.
    Kluger, Jeffrey
    Coleman, Craig I.
    White, C. Michael
    Guertin, Danette
    Shafi, Nabil A.
    Yarlagadda, Ravi K.
    Clyne, Christopher A.
    [J]. HEART RHYTHM, 2010, 7 (06) : 755 - 760
  • [4] A randomized study of the prevention of sudden death in patients with coronary artery disease
    Buxton, AE
    Lee, KL
    Fisher, JD
    Josephson, ME
    Prystowsky, EN
    Hafley, G
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1999, 341 (25) : 1882 - 1890
  • [5] Canadian implantable defibrillator study (CIDS) - A randomized trial of the implantable cardioverter defibrillator against amiodarone
    Connolly, SJ
    Gent, M
    Roberts, RS
    Dorian, P
    Roy, D
    Sheldon, RS
    Mitchell, LB
    Green, MS
    Klein, GJ
    O'Brien, B
    [J]. CIRCULATION, 2000, 101 (11) : 1297 - 1302
  • [6] Comparison of β-blockers, amiodarone plus β-blockers, or sotalol for prevention of shocks from implantable cardioverter defibrillators -: The optic study.: A randomized trial
    Connolly, SJ
    Dorian, P
    Roberts, RS
    Gent, M
    Bailin, S
    Fain, ES
    Thorpe, K
    Champagne, J
    Talajic, M
    Coutu, B
    Gronefeld, GC
    Hohnloser, SH
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2006, 295 (02): : 165 - 171
  • [7] Inappropriate implantable cardioverter-defibrillator shocks in MADIT II
    Daubert, James P.
    Zareba, Wojciech
    Cannom, David S.
    McNitt, Scott
    Rosero, Spencer Z.
    Wang, Paul
    Schuger, Claudio
    Steinberg, Jonathan S.
    Higgins, Steven L.
    Wilber, David J.
    Klein, Helmut
    Andrews, Mark L.
    Hall, W. Jackson
    Moss, Arthur J.
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 51 (14) : 1357 - 1365
  • [8] METAANALYSIS IN CLINICAL-TRIALS
    DERSIMONIAN, R
    LAIRD, N
    [J]. CONTROLLED CLINICAL TRIALS, 1986, 7 (03): : 177 - 188
  • [9] Appropriate Therapy But Not Inappropriate Shocks Predict Survival in Implantable Cardioverter Defibrillator Patients
    Dichtl, Wolfgang
    Wolber, Thomas
    Paoli, Ursula
    Bruellmann, Simon
    Stuehlinger, Markus
    Berger, Thomas
    Spuller, Karin
    Strasak, Alexander
    Pachinger, Otmar
    Haegeli, Laurent M.
    Duru, Firat
    Hintringer, Florian
    [J]. CLINICAL CARDIOLOGY, 2011, 34 (07) : 433 - 436
  • [10] Placebo-controlled, randomized clinical trial of azimilide for prevention of ventricular tachyarrhythmias in patients with an implantable cardioverter defibrillator
    Dorian, P
    Borggrefe, M
    Al-Khalidi, HR
    Hohnloser, SH
    Brum, JM
    Tatla, DS
    Brachmann, J
    Myerburg, RJ
    Cannom, DS
    van der Laan, M
    Holroyde, MJ
    Singer, I
    [J]. CIRCULATION, 2004, 110 (24) : 3646 - 3654