Experimental design and numerical investigation of a photoacoustic sensor for a low-power, continuous-wave, laser-based frequency-domain photoacoustic microscopy

被引:5
作者
Sathiyamoorthy, Krishnan [1 ,2 ,3 ,4 ]
Kolios, Michael C. [1 ,2 ,3 ,4 ]
机构
[1] Ryerson Univ, Dept Phys, Toronto, ON, Canada
[2] Ryerson Univ, Inst Biomed Engn Sci & Technol, Toronto, ON, Canada
[3] St Michaels Hosp, Toronto, ON, Canada
[4] St Michaels Hosp, Keenan Res Ctr Biomed Sci, Toronto, ON, Canada
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
microscope; photoacoustic; lasers; COMSOL; resonator; microphone; biomedical; HIGH-RESOLUTION; INTERFEROMETER; SPECTROSCOPY; GASES;
D O I
10.1117/1.JBO.24.12.121912
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We have developed a photoacoustic (PA) sensor using a low-power, continuous- wave laser and a kHz-range microphone. The sensor is simple, flexible, cost-effective, and compatible with commercial optical microscopes. The sensor enables noncontact PA measurements through air, whereas most current existing PA techniques require an acoustic coupling liquid for detection. The PA sensor has three main components: one is the chamber that holds the sample, the second is a resonator column used to amplify the weak PA signals generated within the sample chamber, and the third is a microphone at the end of the resonator column to detect the amplified signals. The chamber size was designed to be 8 mm x 3 mm as the thermal diffusion length and viscous-thermal damping of air at room pressure and temperature are 2 and 1 mm, respectively. We numerically and experimentally examined the effect of the resonator column size on the frequency response of the PA sensor. The quality factor decreased significantly when the sample chamber size was reduced from 4 mm x 3 mm to 2 mm x 3 mm due to thermos-viscous damping of the air. The quality factor decreased by 27%, demonstrating the need for optimal design for the sample chamber and resonator column size. The system exhibited noise equivalent molecular sensitivity (NEM) per unit bandwidth (NEM/root Delta f) of similar to 19,966 Hz(-1/2) or 33 x 10(-21) mol or 33 zeptomol, which is an improvement of 2.2 times compared to the previous system design. This PA sensor has the potential for noncontact high-resolution PA imaging of materials without the need for coupling fluids. (C) The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License.
引用
收藏
页数:12
相关论文
共 54 条
  • [1] Acoustics Module, COMS MULT
  • [2] [Anonymous], 1997, SR540 LOW JITT OPT C
  • [3] Bageshwar DV, 2010, EURASIAN J ANAL CHEM, V5, P187
  • [4] Probe beam deflection technique as acoustic emission directionality sensor with photoacoustic emission source
    Barnes, Ronald A., Jr.
    Maswadi, Saher
    Glickman, Randolph
    Shadaram, Mehdi
    [J]. APPLIED OPTICS, 2014, 53 (03) : 511 - 519
  • [5] Baumann B., 2008, MODELING NUMERICAL I, P17, DOI [10.5772/6798, DOI 10.5772/6798]
  • [6] Finite element calculation of photoacoustic signals
    Baumann, Bernd
    Wolff, Marcus
    Kost, Bernd
    Groninga, Hinrich
    [J]. APPLIED OPTICS, 2007, 46 (07) : 1120 - 1125
  • [7] Biomedical photoacoustic imaging
    Beard, Paul
    [J]. INTERFACE FOCUS, 2011, 1 (04) : 602 - 631
  • [8] Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection
    Beard, PC
    Pérennès, F
    Mills, TN
    [J]. IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) : 1575 - 1582
  • [9] Bell A G, 1880, AM J SCI, V20, P305
  • [10] Optoacoustic imaging based on the interferometric measurement of surface displacement
    Carp, Stefan A.
    Venugopalan, Vasan
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (06)