Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry

被引:9
作者
Fernandes, Sara R. [1 ,2 ]
Barreiros, Luisa [1 ,2 ]
Sa, Paula [3 ]
Miro, Manuel [4 ]
Segundo, Marcela A. [1 ]
机构
[1] Univ Porto, Fac Farm, Dept Ciencias Quim, REQUIMTE,LAQV, Rua Jorge Viterbo Ferreira 228, P-4050313 Porto, Portugal
[2] Inst Politecn Porto, Escola Super Saude, Rua Dr Antonio Bernardino de Almeida 400, P-4200072 Porto, Portugal
[3] Ctr Hosp Univ Porto, P-4099001 Porto, Portugal
[4] Univ Balearic Isl, Dept Chem, FI TRACE Grp, E-07122 Palma De Mallorca, Spain
关键词
Bead injection; Lab-on-valve; Automation; Mass spectrometry; Tranexamic acid; Urine; LIQUID-CHROMATOGRAPHY; SAMPLE PREPARATION; PLASMA;
D O I
10.1007/s00216-021-03606-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automatic micro-solid-phase extraction (mu SPE) method using on-line renewable sorbent beads followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established for the determination of tranexamic acid (TXA) in urine. The mu SPE method was based on the bead injection (BI) concept combined with the mesofluidic lab-on-valve (LOV) platform. All steps of the mu SPE-BI-LOV were implemented by computer programming, rendering enhanced precision on time and flow events. Several parameters, including the type of sorbent, volume and composition of the conditioning solution, washing solution, and eluent composition, were evaluated to improve the extraction efficiency. The best results were obtained with a hydrophilic-lipophilic balanced mixed-mode sorbent, decorated with sulfonic acid groups (Oasis MCX), and 99% acetonitrile-water (50:50, v/v)-1% ammonium hydroxide as eluent. Chromatographic separation was performed using a BEH amide column coupled to MS/MS detection in positive ionization mode. Good linearity was achieved (R-2 > 0.998) for TXA concentrations in urine ranging from 300 to 3000 ng mL(-1), with LOD and LOQ of 30 and 65 ng mL(-1), respectively. Dilution integrity was observed for dilution factors up to 20,000 times, providing the extension of the upper limit of quantification to 12 mg mL(-1). The method was validated according to international guidelines and successfully applied to urine samples collected during scoliosis surgery of pediatric patients treated with TXA.
引用
收藏
页码:649 / 659
页数:11
相关论文
共 34 条
[11]   Development of SPME method for concomitant sample preparation of rocuronium bromide and tranexamic acid in plasma [J].
Gorynski, Krzysztof ;
Bojko, Barbara ;
Kluger, Michael ;
Jerath, Angela ;
Wasowicz, Marcin ;
Pawliszyn, Janusz .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 92 :183-192
[12]   Optimization and validation of an HPLC-UV method for determination of tranexamic acid in a dosage form and in human urine [J].
Hadad, Ghada M. ;
El-Gindy, Alaa ;
Mahmoud, Waleed M. M. .
CHROMATOGRAPHIA, 2007, 66 (5-6) :311-317
[13]   The current place of tranexamic acid in the management of bleeding [J].
Hunt, B. J. .
ANAESTHESIA, 2015, 70
[14]   Simultaneous Determination of Statins in Human Urine by Dilute-and-Shoot-Liquid Chromatography-Mass Spectrometry [J].
Jang, Haejong ;
Mai, Xuan-Lan ;
Lee, Gunhee ;
Ahn, Jae Hyoung ;
Rhee, Jongsook ;
Quoc-Ky Truong ;
Dinh Vinh ;
Hong, Jongki ;
Kim, Kyeong Ho .
MASS SPECTROMETRY LETTERS, 2018, 9 (04) :95-99
[15]   Tranexamic Acid Dosing for Cardiac Surgical Patients With Chronic Renal Dysfunction: A New Dosing Regimen [J].
Jerath, Angela ;
Yang, Qi Joy ;
Pang, K. Sandy ;
Looby, Nikita ;
Reyes-Garces, Nathaly ;
Vasiljevic, Tijana ;
Bojko, Barbara ;
Pawliszyn, Janusz ;
Wijeysundera, Duminda ;
Beattie, W. Scott ;
Yau, Terrence M. ;
Wasowicz, Marcin .
ANESTHESIA AND ANALGESIA, 2018, 127 (06) :1323-1332
[16]   Tranexamic Acid-Associated Seizures: Causes and Treatment [J].
Lecker, Irene ;
Wang, Dian-Shi ;
Whissell, Paul D. ;
Avramescu, Sinziana ;
Mazer, C. David ;
Orser, Beverley A. .
ANNALS OF NEUROLOGY, 2016, 79 (01) :18-26
[17]   Therapeutic drug monitoring of tranexamic acid in plasma and urine of renally impaired patients using solid phase microextraction [J].
Looby, Nikita ;
Vasiljevic, Tijana ;
Reyes-Garces, Nathaly ;
Roszkowska, Anna ;
Bojko, Barbara ;
Wasowicz, Marcin ;
Jerath, Angela ;
Pawliszyn, Janusz .
TALANTA, 2021, 225
[18]   Solid phase microextraction coupled to mass spectrometry via a microfluidic open interface for rapid therapeutic drug monitoring [J].
Looby, Nikita T. ;
Tascon, Marcos ;
Acquaro, Vinicius R., Jr. ;
Reyes-Garces, Nathaly ;
Vasiljevic, Tijana ;
Gomez-Rios, German Augusto ;
Wasowicz, Marcin ;
Pawliszyn, Janusz .
ANALYST, 2019, 144 (12) :3721-3728
[19]   Tranexamic acid therapy for heavy menstrual bleeding [J].
Lumsden, Mary Ann ;
Wedisinghe, Lilantha .
EXPERT OPINION ON PHARMACOTHERAPY, 2011, 12 (13) :2089-2095
[20]   Recent Developments in Selective Materials for Solid Phase Extraction [J].
Madikizela, Lawrence Mzukisi ;
Ncube, Somandla ;
Chimuka, Luke .
CHROMATOGRAPHIA, 2019, 82 (08) :1171-1189