Automatic and renewable micro-solid-phase extraction based on bead injection lab-on-valve system for determination of tranexamic acid in urine by UHPLC coupled with tandem mass spectrometry

被引:9
作者
Fernandes, Sara R. [1 ,2 ]
Barreiros, Luisa [1 ,2 ]
Sa, Paula [3 ]
Miro, Manuel [4 ]
Segundo, Marcela A. [1 ]
机构
[1] Univ Porto, Fac Farm, Dept Ciencias Quim, REQUIMTE,LAQV, Rua Jorge Viterbo Ferreira 228, P-4050313 Porto, Portugal
[2] Inst Politecn Porto, Escola Super Saude, Rua Dr Antonio Bernardino de Almeida 400, P-4200072 Porto, Portugal
[3] Ctr Hosp Univ Porto, P-4099001 Porto, Portugal
[4] Univ Balearic Isl, Dept Chem, FI TRACE Grp, E-07122 Palma De Mallorca, Spain
关键词
Bead injection; Lab-on-valve; Automation; Mass spectrometry; Tranexamic acid; Urine; LIQUID-CHROMATOGRAPHY; SAMPLE PREPARATION; PLASMA;
D O I
10.1007/s00216-021-03606-y
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
An automatic micro-solid-phase extraction (mu SPE) method using on-line renewable sorbent beads followed by liquid chromatography-tandem mass spectrometry (LC-MS/MS) was established for the determination of tranexamic acid (TXA) in urine. The mu SPE method was based on the bead injection (BI) concept combined with the mesofluidic lab-on-valve (LOV) platform. All steps of the mu SPE-BI-LOV were implemented by computer programming, rendering enhanced precision on time and flow events. Several parameters, including the type of sorbent, volume and composition of the conditioning solution, washing solution, and eluent composition, were evaluated to improve the extraction efficiency. The best results were obtained with a hydrophilic-lipophilic balanced mixed-mode sorbent, decorated with sulfonic acid groups (Oasis MCX), and 99% acetonitrile-water (50:50, v/v)-1% ammonium hydroxide as eluent. Chromatographic separation was performed using a BEH amide column coupled to MS/MS detection in positive ionization mode. Good linearity was achieved (R-2 > 0.998) for TXA concentrations in urine ranging from 300 to 3000 ng mL(-1), with LOD and LOQ of 30 and 65 ng mL(-1), respectively. Dilution integrity was observed for dilution factors up to 20,000 times, providing the extension of the upper limit of quantification to 12 mg mL(-1). The method was validated according to international guidelines and successfully applied to urine samples collected during scoliosis surgery of pediatric patients treated with TXA.
引用
收藏
页码:649 / 659
页数:11
相关论文
共 34 条
[1]   Determination of tranexamic acid in human plasma by UHPLC coupled with tandem mass spectrometry targeting sub-microgram per milliliter levels [J].
Barreiros, Luisa ;
Amoreira, Julia L. ;
Machado, Sandia ;
Fernandes, Sara R. ;
Silva, Eduarda M. P. ;
Sa, Paula ;
Kietaibl, Sibylle ;
Segundo, Marcela A. .
MICROCHEMICAL JOURNAL, 2019, 144 :144-150
[2]   Therapeutic Monitoring of Tranexamic Acid Concentration: High-Throughput Analysis With Solid-Phase Microextraction [J].
Bojko, Barbara ;
Vuckovic, Dajana ;
Mirnaghi, Fatemeh ;
Cudjoe, Erasmus ;
Wasowicz, Marcin ;
Jerath, Angela ;
Pawliszyn, Janusz .
THERAPEUTIC DRUG MONITORING, 2012, 34 (01) :31-37
[3]   Determination of tranexamic acid concentration by solid phase microextraction and liquid chromatography-tandem mass spectrometry: First step to in vivo analysis [J].
Bojko, Barbara ;
Vuckovic, Dajana ;
Cudjoe, Erasmus ;
Hoque, Md Ehsanul ;
Mirnaghi, Fatemeh ;
Wasowicz, Marcin ;
Jerath, Angela ;
Pawliszyn, Janusz .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2011, 879 (32) :3781-3787
[4]   The many roles of tranexamic acid: An overview of the clinical indications for TXA in medical and surgical patients [J].
Cai, Johnny ;
Ribkoff, Jessica ;
Olson, Sven ;
Raghunathan, Vikram ;
Al-Samkari, Hanny ;
DeLoughery, Thomas G. ;
Shatzel, Joseph J. .
EUROPEAN JOURNAL OF HAEMATOLOGY, 2020, 104 (02) :79-87
[5]   Recent advances in flow-based automated solid-phase extraction [J].
Calderilla, Carlos ;
Maya, Fernando ;
Leal, Luz O. ;
Cerda, Victor .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2018, 108 :370-380
[6]   The miniaturization of bioanalytical assays and sample pretreatments by exploiting meso-fluidic lab-on-valve configurations: A review [J].
Chen, Xu-Wei ;
Wang, Jian-Hua .
ANALYTICA CHIMICA ACTA, 2007, 602 (02) :173-180
[7]   Dilute-and-shoot-liquid chromatography-mass spectrometry for urine analysis in doping control and analytical toxicology [J].
Deventer, K. ;
Pozo, O. J. ;
Verstraete, A. G. ;
Van Eenoo, P. .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2014, 55 :1-13
[8]  
EMA,, 2011, Guideline on bioanalytical method validation
[9]   PHARMACOKINETICS OF TRANEXAMIC ACID AFTER INTRAVENOUS ADMINISTRATION TO NORMAL VOLUNTEERS [J].
ERIKSSON, O ;
KJELLMAN, H ;
PILBRANT, A ;
SCHANNONG, M .
EUROPEAN JOURNAL OF CLINICAL PHARMACOLOGY, 1974, 7 (05) :375-380
[10]  
European Commission (EC), 2002, COMMISSION DECISION, VVolume 221, P8, DOI DOI 10.1017/CBO9781107415324.004