Do patient-specific instruments (PSI) for UKA allow non-expert surgeons to achieve the same saw cut accuracy as expert surgeons?

被引:20
作者
Jones, Gareth G. [1 ]
Logishetty, K. [1 ]
Clarke, S. [1 ]
Collins, R. [1 ]
Jaere, M. [1 ]
Harris, S. [1 ]
Cobb, J. P. [1 ]
机构
[1] Imperial Coll London, MSk Lab, Charing Cross Hosp, 7th Floor Lab Block, London W6 8RF, England
关键词
Unicompartmental knee arthroplasty; Partial knee replacement; Patient-specific instrumentation; PSI; Patient-specific guides; 3D printing; UNICOMPARTMENTAL KNEE ARTHROPLASTY; NATIONAL JOINT REGISTRY; COMPONENT POSITION; MATCHED PATIENTS; OXFORD UKA; REPLACEMENT; OUTCOMES; ENGLAND; WALES;
D O I
10.1007/s00402-018-3031-9
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction High-volume unicompartmental knee arthroplasty (UKA) surgeons have lower revision rates, in part due to improved intra-operative component alignment. This study set out to determine whether PSI might allow non-expert surgeons to achieve the same level of accuracy as expert surgeons. Materials and methods Thirty-four surgical trainees with no prior experience of UKA, and four high-volume UKA surgeons were asked to perform the tibial saw cuts for a medial UKA in a sawbone model using both conventional and patient-specific instrumentation (PSI) with the aim of achieving a specified pre-operative plan. Half the participants in each group started with conventional instrumentation, and half with PSI. CT scans of the 76 cut sawbones were then segmented and reliably orientated in space, before saw cut position in the sagittal, coronal and axial planes was measured, and compared to the pre-operative plan. Results The compound error (absolute error in the coronal, sagittal and axial planes combined) for experts using conventional instruments was significantly less than that of the trainees (11.6 degrees +/- 4.0 degrees v 7.7 degrees +/- 2.3 degrees, p = 0.029). PSI improved trainee accuracy to the same level as experts using conventional instruments (compound error 5.5 degrees +/- 3.4 degrees v 7.7 degrees +/- 2.3 degrees, p = 0.396) and patient-specific instruments (compound error 5.5 degrees +/- 3.4 degrees v 7.3 degrees +/- 4.1 degrees, p = 0.3). PSI did not improve the accuracy of high-volume surgeons (p = 0.3). Conclusions In a sawbone model, PSI allowed inexperienced surgeons to achieve more accurate saw cuts, equivalent to expert surgeons, and thus has the potential to reduce revision rates. The next test will be to determine whether these results can be replicated in a clinical trial.
引用
收藏
页码:1601 / 1608
页数:8
相关论文
共 37 条
  • [1] The impact of patient-specific instrumentation on unicompartmental knee arthroplasty: a prospective randomised controlled study
    Alvand, Abtin
    Khan, Tanvir
    Jenkins, Cathy
    Rees, Jonathan L.
    Jackson, William F.
    Dodd, Christopher A. F.
    Murray, David W.
    Price, Andrew J.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2018, 26 (06) : 1662 - 1670
  • [2] [Anonymous], 2015, ANN REPORT, DOI [10.1039/C1DT90165F, DOI 10.1039/C1DT90165F]
  • [3] [Anonymous], 2015, AUST ORTH ASS NAT JT
  • [4] Higher revision risk for unicompartmental knee arthroplasty in low-volume hospitals
    Badawy, Mona
    Espehaug, Birgitte
    Indrekvam, Kari
    Havelin, Leif I.
    Furnes, Ove
    [J]. ACTA ORTHOPAEDICA, 2014, 85 (04) : 342 - 347
  • [5] Center and Surgeon Volume Influence the Revision Rate Following Unicondylar Knee Replacement
    Baker, Paul
    Jameson, Simon
    Critchley, Rebecca
    Reed, Mike
    Gregg, Paul
    Deehan, David
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2013, 95A (08) : 702 - 709
  • [6] Patient specific cutting blocks are currently of no proven value
    Barrack, R. L.
    Ruh, E. L.
    Williams, B. M.
    Ford, A. D.
    Foreman, K.
    Nunley, R. M.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2012, 94B (11): : 95 - 99
  • [7] Unicompartmental knee arthroplasty surgery - 10-year minimum follow-up period
    Cartier, P
    Sanouiller, JL
    Grelsamer, RP
    [J]. JOURNAL OF ARTHROPLASTY, 1996, 11 (07) : 782 - 788
  • [8] Medial unicompartmental knee arthroplasty: Does tibial component position influence clinical outcomes and arthroplasty survival?
    Chatellard, R.
    Sauleau, V.
    Colmar, M.
    Robert, H.
    Raynaud, G.
    Brilhault, J.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2013, 99 (04) : S219 - S225
  • [9] The anatomical tibial axis - Reliable rotational orientation in knee replacement
    Cobb, J. P.
    Dixon, H.
    Dandachli, W.
    Iranpour, F.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2008, 90B (08): : 1032 - 1038
  • [10] Patient-Specific Versus Conventional Instrumentation for Total Knee Arthroplasty: Peri-Operative and Cost Differences
    DeHaan, Alexander M.
    Adams, Jacob R.
    DeHart, Matthew L.
    Huff, Thomas W.
    [J]. JOURNAL OF ARTHROPLASTY, 2014, 29 (11) : 2065 - 2069