Tip air injection to extend stall margin of multi-stage axial flow compressor with inlet radial distortion

被引:38
作者
Li, Jichao [1 ]
Du, Juan [1 ]
Geng, Shaojuan [1 ]
Li, Fan [1 ]
Zhang, Hongwu [1 ]
机构
[1] Univ Chinese Acad Sci, CAS, Inst Engn Thermophys, Adv Gas Turbine Lab, Beijing 100190, Peoples R China
基金
美国国家科学基金会;
关键词
Compressor; Inlet radial distortion; Stall margin; Tip air injection; Tip leakage flow; Aerodynamic parameters; CASING TREATMENT; STABILITY; ENHANCEMENT; PERFORMANCE; STAGE;
D O I
10.1016/j.ast.2019.105554
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
To prevent the deterioration of the inlet tip and hub radial distortion on stall margin, tip air injection was experimentally studied in a three-stage axial flow compressor. By generating a total pressure distortion intensity of 16.8% and 8.6%, the inlet tip and hub radial distortion can obtain stall margin variation of -5.1% and 10.5%, respectively. With the help of time-resolved pressure transducers installed on the casing wall and five-hole probes installed downstream of each rotor blade row, the unsteady measurement results demonstrate that the first stage stalls first under different inflow conditions and only the unsteady tip leakage flow at the first stage becomes stronger near the stall limit. Therefore, tip air injection is applied at the first stage under the distorted inflow to ensure the stable operation. Under inlet tip radial distortion, which strengths the unsteady tip leakage flow and blade tip separation reflected by the outlet axial velocity and flow angle, tip air injection can weaken the unsteady tip leakage flow, and remove the tip separation at the first stage, thereby making the second stage stall first such that only stall margin improvement of 19.2% can be obtained compared with uniform inflow. Although hub radial distortion can delay the occurrence of stall by weakening unsteady tip leakage flow and increasing the tip flow capability, overlarge injection can still improve the stall margin by 20.5% through further weakening the unsteady tip leakage flow and reducing the blade tip separation. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:13
相关论文
共 43 条
  • [1] [Anonymous], [No title captured]
  • [2] [Anonymous], [No title captured]
  • [3] [Anonymous], 2001, 2001044 ETC
  • [4] [Anonymous], 1978, TP1294 NASA
  • [5] [Anonymous], [No title captured]
  • [6] Effects of inlet radial distortion on the type of stall precursor in low-speed axial compressor
    Arshad, Ali
    Li, Qiushi
    Li, Simin
    Pan, Tianyu
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART G-JOURNAL OF AEROSPACE ENGINEERING, 2018, 232 (01) : 55 - 67
  • [7] Secondary Flows, Endwall Effects, and Stall Detection in Axial Compressor Design
    Banjac, Milan
    Petrovic, Milan V.
    Wiedermann, Alexander
    [J]. JOURNAL OF TURBOMACHINERY-TRANSACTIONS OF THE ASME, 2015, 137 (05):
  • [8] Bennington M. A., 2008, GT2008-51319
  • [9] Brandt H., 2002, GT200230639 ASME
  • [10] Sensitivity of Multistage Compressor Performance to Inlet Boundary Conditions
    Brossman, John R.
    Ball, Patrick R.
    Smith, Natalie R.
    Methel, Jeanne C.
    Key, Nicole L.