Improving Annual Energy Production of Doubly-Fed Induction Generators

被引:2
|
作者
Wang, Xuezhou [1 ]
Liu, Dong [2 ]
Polinder, Henk [1 ]
机构
[1] Delft Univ Technol, Dept Maritime & Transport Technol, NL-2600 AA Delft, Netherlands
[2] Hohai Univ, Coll Energy & Elect Engn, Nanjing 211100, Peoples R China
关键词
Doubly-fed induction generator (DFIG); annual energy production (AEP); aerodynamic model; Delta-Y connection; short-circuited connection; SYSTEM; CONVERSION;
D O I
10.1109/TEC.2021.3063478
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Doubly fed induction generator (DFIG) based wind turbines are most employed for onshore applications because of their cast-effectiveness. The drivetrain improvement is barely studied due to the maturity of the DFIG based systems. This paper investigates two methods for improving the annual energy production (AEP) of the DFIG based wind turbines. They are referred to as short-circuited and Delta-Y-connected DFIGs. The origins of the AEP improvement are elaborated from the drivetrain perspective. The improvement is quantified by the aerodynamic model of the turbine and the steady-state model of the DFIG. The two methods are then compared when applied to six regions with different wind speed distributions. The AEP improvements at six regions are evaluated and compared to derive the feasibility of the methods for different locations.
引用
收藏
页码:3405 / 3413
页数:9
相关论文
共 50 条
  • [21] Novel Bearing Current Suppression Approach in Doubly-Fed Induction Generators
    Liu, Ruifang
    Yang, Erle
    Chen, Jiayao
    Niu, Shuangxia
    IEEE ACCESS, 2019, 7 : 171525 - 171532
  • [22] Comparison of stabilizing methods for doubly-fed induction generators for wind turbines
    La Seta, Piergiovanni
    Schegner, Peter
    2005 International Conference on Future Power Systems (FPS), 2005, : 468 - 473
  • [23] Reactive Power Control in Doubly-Fed Induction Generators for Wind Turbines
    Rabelo, B.
    Hofmann, W.
    Silva, J. L.
    Oliveira, R. G.
    Silva, S. R.
    2008 IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-10, 2008, : 106 - +
  • [24] Passivity Based Control of Doubly-Fed Induction Generators in Wind Turbines
    Lopez-Garcia, I.
    Jimenez-Mondragon, V. M.
    Campero-Littlewood, E.
    Espinosa-Perez, G. R.
    2010 IEEE ELECTRONICS, ROBOTICS AND AUTOMOTIVE MECHANICS CONFERENCE (CERMA 2010), 2010, : 607 - 612
  • [25] Behaviour and Protection of doubly-fed induction generators during network faults
    Foster, Sarah
    Xu, Lie
    Fox, Brendan
    2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, 2009, : 405 - 412
  • [26] Efficient Direct Model Predictive Control for Doubly-Fed Induction Generators
    Abdelrahem, Mohamed
    Kennel, Ralph
    ELECTRIC POWER COMPONENTS AND SYSTEMS, 2017, 45 (05) : 574 - 587
  • [27] A new monitoring system for wind turbines with doubly-fed induction generators
    Yazidi, A.
    Capolino, G. A.
    Filippetti, F.
    Casadei, D.
    CIRCUITS AND SYSTEMS FOR SIGNAL PROCESSING , INFORMATION AND COMMUNICATION TECHNOLOGIES, AND POWER SOURCES AND SYSTEMS, VOL 1 AND 2, PROCEEDINGS, 2006, : 1142 - 1145
  • [28] Particle swarm optimisation technique to improve energy efficiency of doubly-fed induction generators for wind turbines
    Sompracha, Cherngchai
    Jayaweera, Dilan
    Tricoli, Pietro
    JOURNAL OF ENGINEERING-JOE, 2019, (18): : 4890 - 4895
  • [29] Multi-objective model predictive control of doubly-fed induction generators for wind energy conversion
    Hu, Jiefeng
    Li, Yong
    Zhu, Jianguo
    IET GENERATION TRANSMISSION & DISTRIBUTION, 2019, 13 (01) : 21 - 29
  • [30] Effects of Wind Turbines Equipped with Doubly-fed Induction Generators on Distance Protection
    Hossein Kazemi KAREGAR
    Maryam KHODDAM
    电力系统自动化, 2012, 36 (08) : 128 - 131