Simultaneous pure T2 and varying T2′ -weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses

被引:9
|
作者
Wang, Fuyixue [1 ,2 ,3 ]
Dong, Zijing [1 ,4 ]
Wald, Lawrence L. [1 ,2 ,3 ]
Polimeni, Jonathan R. [1 ,2 ,3 ]
Setsompop, Kawin [5 ,6 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] MIT, Harvard MIT Hlth Sci & Technol, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[3] Harvard Med Sch, Dept Radiol, Boston, MA 02115 USA
[4] MIT, Elect Engn & Comp Sci, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[5] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[6] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
Ultra-high field; Multi-echo; Spin-echo; T-2; BOLD; Microvascular specificity; Laminar fMRI; FAST SPIN-ECHO; CONTRAST SENSITIVITY; SIGNAL CHANGES; EPI; SPECIFICITY; MRI; MODEL; SENSE; ACQUISITIONS; ENHANCEMENT;
D O I
10.1016/j.neuroimage.2021.118641
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T-2' contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T-2' contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T-2' weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T-2'-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B-0 drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T-2' weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity.
引用
收藏
页数:12
相关论文
共 48 条
  • [41] Time-saving opportunities in knee osteoarthritis: T2 mapping and structural imaging of the knee using a single 5-min MRI scan
    Eijgenraam, Susanne M.
    Chaudhari, Akshay S.
    Reijman, Max
    Bierma-Zeinstra, Sita M. A.
    Hargreaves, Brian A.
    Runhaar, Jos
    Heijboer, Frank W. J.
    Gold, Garry E.
    Oei, Edwin H. G.
    EUROPEAN RADIOLOGY, 2020, 30 (04) : 2231 - 2240
  • [42] Single-Shot T1 Mapping Using Simultaneous Acquisitions of Spin- and Stimulated-Echo-Planar Imaging (2D ss-SESTEPI)
    Shi, Xianfeng
    Kim, Seong-Eun
    Jeong, Eun-Kee
    MAGNETIC RESONANCE IN MEDICINE, 2010, 64 (03) : 734 - 742
  • [43] Long T2 suppression in native lung 3-D imaging using k-space reordered inversion recovery dual-echo ultrashort echo time MRI
    Gai, Neville D.
    Malayeri, Ashkan A.
    Bluemke, David A.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (04) : 387 - 395
  • [44] Fast dual-echo estimation of apparent long T2 fraction using ultrashort echo time magnetic resonance imaging in tibialis tendons and its osteoporosis-related differences in women
    Jerban, Saeed
    Moazamian, Dina
    Ma, Yajun
    Afsahi, Amir Masoud
    Dwek, Sophia
    Athertya, Jiyo
    Malhi, Bhavsimran
    Jang, Hyungseok
    Woods, Gina
    Chung, Christine B.
    Du, Jiang
    Chang, Eric Y.
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2024, 14 (04) : 3146 - 3156
  • [45] Transverse Relaxation Time (T2) Mapping in the Brain With Off-Resonance Correction Using Phase-Cycled Steady-State Free Precession Imaging
    Deoni, Sean C. L.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2009, 30 (02) : 411 - 417
  • [46] Single- and Bicomponent Analyses of T2? Relaxation in Knee Tendon and Ligament by Using 3D Ultrashort Echo Time Cones (UTE Cones) Magnetic Resonance Imaging
    Liu, Jin
    Nazaran, Amin
    Ma, Yajun
    Chen, Haimei
    Zhu, Yanchun
    Du, Jiang
    Li, Shaolin
    Zhou, Quan
    Zhao, Yinghua
    BIOMED RESEARCH INTERNATIONAL, 2019, 2019
  • [47] Effect of an Ultrahigh b Value of 3000 s/mm2 and the Minimal Echo-time on Image Quality and the T2 Shine-through Effect in Diffusion-weighted Imaging of the Liver at 3T: Phantom and Clinical Pilot Studies
    Fukushima, Keita
    Sano, Katsuhiro
    Machida, Haruhiko
    Kariyasu, Toshiya
    Yoshioka, Tatsuya
    Takahashi, Sanae
    Nakanishi, Akihito
    Kusahara, Hiroshi
    Yokoyama, Kenichi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2023, 22 (02) : 232 - 240
  • [48] Short T2 imaging using a 3D double adiabatic inversion recovery prepared ultrashort echo time cones (3D DIR-UTE-Cones) sequence
    Ma, Ya-Jun
    Zhu, Yanchun
    Lu, Xing
    Carl, Michael
    Chang, Eric Y.
    Du, Jiang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (05) : 2555 - 2563