Simultaneous pure T2 and varying T2′ -weighted BOLD fMRI using Echo Planar Time-resolved Imaging for mapping cortical-depth dependent responses

被引:9
|
作者
Wang, Fuyixue [1 ,2 ,3 ]
Dong, Zijing [1 ,4 ]
Wald, Lawrence L. [1 ,2 ,3 ]
Polimeni, Jonathan R. [1 ,2 ,3 ]
Setsompop, Kawin [5 ,6 ]
机构
[1] Massachusetts Gen Hosp, Athinoula A Martinos Ctr Biomed Imaging, Charlestown, MA 02129 USA
[2] MIT, Harvard MIT Hlth Sci & Technol, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[3] Harvard Med Sch, Dept Radiol, Boston, MA 02115 USA
[4] MIT, Elect Engn & Comp Sci, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[5] Stanford Univ, Dept Radiol, Stanford, CA 94305 USA
[6] Stanford Univ, Dept Elect Engn, Stanford, CA 94305 USA
关键词
Ultra-high field; Multi-echo; Spin-echo; T-2; BOLD; Microvascular specificity; Laminar fMRI; FAST SPIN-ECHO; CONTRAST SENSITIVITY; SIGNAL CHANGES; EPI; SPECIFICITY; MRI; MODEL; SENSE; ACQUISITIONS; ENHANCEMENT;
D O I
10.1016/j.neuroimage.2021.118641
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
Spin-echo (SE) BOLD fMRI has high microvascular specificity, and thus provides a more reliable means to localize neural activity compared to conventional gradient-echo BOLD fMRI. However, the most common SE BOLD acquisition method, SE-EPI, is known to suffer from T-2' contrast contamination with undesirable draining vein bias. To address this, in this study, we extended a recently developed distortion/blurring-free multi-shot EPI technique, Echo-Planar Time-resolved Imaging (EPTI), to cortical-depth dependent SE-fMRI at 7T to test whether it could provide purer SE BOLD contrast with minimal T-2' contamination for improved neuronal specificity. From the same acquisition, the time-resolved feature of EPTI also provides a series of asymmetric SE (ASE) images with varying T-2' weightings, and enables extraction of data equivalent to conventional SE EPI with different echo train lengths (ETLs). This allows us to systematically examine how T-2'-contribution affects different SE acquisition strategies using a single dataset. A low-rank spatiotemporal subspace reconstruction was implemented for the SE-EPTI acquisition, which incorporates corrections for both shot-to-shot phase variations and dynamic B-0 drifts. SE-EPTI was used in a visual task fMRI experiment to demonstrate that i) the pure SE image provided by EPTI results in the highest microvascular specificity; ii) the ASE EPTI series, with a graded introduction of T-2' weightings at time points farther away from the pure SE, show a gradual sensitivity increase along with increasing draining vein bias; iii) the longer ETL seen in conventional SE EPI acquisitions will induce more draining vein bias. Consistent results were observed across multiple subjects, demonstrating the robustness of the proposed technique for SE-BOLD fMRI with high specificity.
引用
收藏
页数:12
相关论文
共 48 条
  • [21] Magnetic Resonance Fingerprinting Using Echo-Planar Imaging: Joint Quantification of T1 and T2* Relaxation Times
    Rieger, Benedikt
    Zimmer, Fabian
    Zapp, Jascha
    Weingaertner, Sebastian
    Schad, Lothar R.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (05) : 1724 - 1733
  • [22] Simultaneous measurement of T2 and apparent diffusion coefficient (T2+ADC) in the heart with motion-compensated spin echo diffusion-weighted imaging
    Aliotta, Eric
    Moulin, Kevin
    Zhang, Zhaohuan
    Ennis, Daniel B.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (02) : 654 - 662
  • [23] Segmented T1 weighted echo-planar imaging in the abdomen and pelvis. Comparison with T1 TSE and T2 UTSE sequences
    Maubon, A
    Berger, V
    Aubas, P
    Ferru, JM
    Rouanet, JP
    JOURNAL DE RADIOLOGIE, 1999, 80 (03): : 291 - 296
  • [24] Single-shot T2 mapping via multi-echo-train multiple overlapping-echo detachment planar imaging and multitask deep learning
    Ouyang, Binyu
    Yang, Qizhi
    Wang, Xiaoyin
    He, Hongjian
    Ma, Lingceng
    Yang, Qinqin
    Zhou, Zihan
    Cai, Shuhui
    Chen, Zhong
    Wu, Zhigang
    Zhong, Jianhui
    Cai, Congbo
    MEDICAL PHYSICS, 2022, 49 (11) : 7095 - 7107
  • [25] Weighted subtraction in 3D ultrashort echo time (UTE) imaging for visualization of short T2 tissues of the knee
    Lee, Young Han
    Kim, Sungjun
    Song, Ho-Taek
    Kim, InSeong
    Suh, Jin-Suck
    ACTA RADIOLOGICA, 2014, 55 (04) : 454 - 461
  • [26] Identification of the primary motor cortex: value of T2 echo-planar imaging, diffusion-weighted imaging and quantitative apparent diffusion coefficient measurement at 3 T
    Alp Dinçer
    Onur Özyurt
    Canan Erzen
    M. Necmettin Pamir
    European Radiology, 2010, 20 : 931 - 940
  • [27] Ultrashort echo time (UTE) magnetic resonance imaging of the short T2 components in white matter of the brain using a clinical 3T scanner
    Du, Jiang
    Ma, Guolin
    Li, Shihong
    Carl, Michael
    Szeverenyi, Nikolaus M.
    VandenBerg, Scott
    Corey-Bloom, Jody
    Bydder, Graeme M.
    NEUROIMAGE, 2014, 87 : 32 - 41
  • [28] T2 mapping and readout segmentation of long variable echo-train diffusion-weighted imaging for the differentiation of parotid gland tumors
    Wen, Baohong
    Jing, Zhu
    Zhang, Zanxia
    Kun, Fu
    Liang, Liu
    Gao, Eryuan
    Yong, Zhang
    Fei, Han
    Cheng, Jingliang
    Zhu, Jinxia
    EUROPEAN JOURNAL OF RADIOLOGY, 2022, 151
  • [29] Comparison of Ferucarbotran-Enhanced Fluid-Attenuated Inversion-Recovery Echo-Planar, T2-Weighted Turbo Spin-Echo, T2*-Weighted Gradient-Echo, and Diffusion-Weighted Echo-Planar Imaging for Detection of Malignant Liver Lesions
    Fukukura, Yoshihiko
    Kamiyama, Takuro
    Takumi, Koji
    Shindo, Toshikazu
    Higashi, Ryutaro
    Nakajo, Masayuki
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2010, 31 (03) : 607 - 616
  • [30] Imaging and T2 relaxometry of short-T2 connective tissues in the knee using ultrashort echo-time double-echo steady-state (UTEDESS)
    Chaudhari, Akshay S.
    Sveinsson, Bragi
    Moran, Catherine J.
    McWalter, Emily J.
    Johnson, Ethan M.
    Zhang, Tao
    Gold, Garry E.
    Hargreaves, Brian A.
    MAGNETIC RESONANCE IN MEDICINE, 2017, 78 (06) : 2136 - 2148