Effect of dynamic modeling of thermal bridges on the energy performance of residential buildings with high thermal mass for cold climates

被引:36
作者
Ge, Hua [1 ]
Baba, Fuad [1 ]
机构
[1] Concordia Univ, Dept Bldg Civil & Environm Engn, 1455 de Maisonneuve, Montreal, PQ H3G 1M8, Canada
关键词
Thermal bridges; Building envelopes; Multi-unit residential buildings (MURBs); Whole building energy modeling; 3D dynamic modeling of thermal bridges; Equivalent wall method; Equivalent U-value method; WALL METHOD; ENVELOPES;
D O I
10.1016/j.scs.2017.06.016
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper investigates the effect of dynamic modeling of thermal bridges on the energy performance of multi-unit residential buildings with high thermal mass under cold climates of Canada. The simulation results show that the inclusion of thermal bridges increases the annual space heating energy demand by 38-42% and decreases the annual space cooling energy demand by 8-26% for pour-in-place concrete construction for the four cities studied in the province of British Columbia, Canada. The improvement of building envelope connection details significantly reduces the contribution of thermal bridges to 3-4% for the space heating energy demand. Due to the smaller amount of thermal bridges in brick veneer construction, the inclusion of thermal bridges increases the annual space heating energy demand by 24-28%. The dynamic effect of thermal bridges on the energy performance depends on the amount and quality of thermal bridges. Compared to the 3D dynamic modeling approach, the annual space heating energy demand can be underestimated by up to 13% by the equivalent U-value method and up to 10% by the equivalent wall method, respectively. The difference between 3-D dynamic modeling and the equivalent U-value method is reduced to less than 3% when the connection details are improved.
引用
收藏
页码:250 / 263
页数:14
相关论文
共 26 条
[1]   Transient modeling of high-inertial thermal bridges in buildings using the equivalent thermal wall method [J].
Aguilar, F. ;
Solano, J. P. ;
Vicente, P. G. .
APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) :370-377
[2]  
[Anonymous], 2008, EN EFF TRENDS CAN 19
[3]  
[Anonymous], 2013, J ENERGY BUILDINGS
[4]  
[Anonymous], 2009, A440209 CANSA CAN ST
[5]  
[Anonymous], 9012010 ANSIASHRAEIE
[6]  
[Anonymous], 2013, THERM 6 3 WINDOW 6 3
[7]   Dynamic effect of balcony thermal bridges on the energy performance of a high-rise residential building in Canada [J].
Baba, Fuad ;
Ge, Hua .
ENERGY AND BUILDINGS, 2016, 116 :78-88
[8]  
BC Hydro Power Smart, 2014, A technical report
[9]   Calculation of thermal bridges in (Nordic) building envelopes - Risk of performance failure due to inconsistent use of methodology [J].
Berggren, Bjorn ;
Wall, Maria .
ENERGY AND BUILDINGS, 2013, 65 :331-339
[10]   Effect of 2D modelling of thermal bridges on the energy performance of buildings -: Numerical application on the Matisse apartment [J].
Déqué, F ;
Ollivier, F ;
Roux, JJ .
ENERGY AND BUILDINGS, 2001, 33 (06) :583-587