Bond strength of binary titanium alloys to porcelain

被引:35
作者
Yoda, M
Konno, T
Takada, Y
Iijima, K
Griggs, J
Okuno, O
Kimura, K
Okabe, T
机构
[1] Tohoku Univ, Grad Sch Dent, Dept Oral Rehabil & Mat Sci, Div Fixed Prosthodont,Aoba Ku, Sendai, Miyagi 9808575, Japan
[2] Tohoku Univ, Grad Sch Dent, Dept Oral Rehabil & Mat Sci, Div Dent Biomat,Aoba Ku, Sendai, Miyagi 9808575, Japan
[3] Texas A&M Univ, Baylor Coll Dent, Hlth Sci Ctr, Dept Biomat Sci, Dallas, TX 75246 USA
关键词
binary titanium alloys; porcelain fused to metal; bond strength; three-point bend test; metal-ceramic bonding;
D O I
10.1016/S0142-9612(00)00329-X
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The purpose of this study was to investigate the bond strength between porcelain and experimental cast titanium alloys. Eleven binary titanium alloys were examined: Ti-Cr (15, 20, 25 wt %), Ti-Pd (15, 20, 25 wt%), Ti-Ag (10, 15. 20 wt%), and Ti-Cu (5, 10 wt%). As controls, the bond strengths For commercially pure titanium (KS-50, Kobelco, Japan) and a high noble gold alloy (KIK, Ishifuku, Japan) were also examined. Castings were made using a centrifugal casting unit (Ticast Super R. Selec Co., Japan). Commercial porcelain for titanium (TITAN, Noritake, Japan) was applied to cast specimens. The bond strengths were evaluated using a three-point bend test according to ISO 9693. Since the elastic modulus value is needed to evaluate the bond strength, the modulus was measured for each alloy using a three-point bend test. Results were analyzed using one-way ANOVA/S-N-K test (alpha = 0.05). Although the elastic moduli of the Ti-Pd alloys were significantly lower than those of other alloys (p = 0.0001), there was a significant difference in bond strength only between the Ti-25Pd and Ti-15Ag alloys (p = 0.009). The strengths determined for all the experimental alloys ranged from 29.4 to 37.2 MPa, which are above the minimum value required by the ISO specification (25 MPa). (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:1675 / 1681
页数:7
相关论文
共 19 条
[1]   COMPARATIVE-EVALUATION OF CERAMIC-METAL BOND TESTS USING FINITE-ELEMENT STRESS-ANALYSIS [J].
ANUSAVICE, KJ ;
DEHOFF, PH ;
FAIRHURST, CW .
JOURNAL OF DENTAL RESEARCH, 1980, 59 (03) :608-613
[2]  
GUHA A, 1985, ASM METALS HDB, V8, P132
[3]   THE PHYSICAL METALLURGY OF TITANIUM ALLOYS [J].
JAFFEE, RI .
PROGRESS IN METAL PHYSICS, 1958, 7 :65-&
[4]  
KIMURA K, 1970, B JPN I MET, V9, P620
[5]   Thermal stresses in metal-ceramic specimens for the ISO crack initiation test (three-point flexure bond test) [J].
Lenz, J ;
Kessel, S .
DENTAL MATERIALS, 1998, 14 (04) :277-280
[6]   BOND STRENGTH OF METAL-CERAMIC SYSTEMS IN 3-POINT FLEXURE BOND TEST [J].
LENZ, J ;
SCHWARZ, S ;
SCHWICKERATH, H ;
SPERNER, F ;
SCHAFER, A .
JOURNAL OF APPLIED BIOMATERIALS, 1995, 6 (01) :55-64
[7]  
MURRAY JL, 1987, ALLOY PHASE DIAGRAMS
[8]  
OKABE T, 1995, CELL MATER, V5, P211
[9]  
OKUNO O, 1985, J JPN SOC DENT MAT D, V4, P708
[10]  