The Accuracy of a Postprocessing Technique-Volume Render Mode-in Three-Dimensional Endoanal Ultrasonography of Anal Abscesses and Fistulas

被引:18
作者
Sudol-Szopinska, Iwona [1 ,2 ]
Kolodziejczak, Malgorzata [2 ]
Szopinski, Tomasz R. [3 ]
机构
[1] Med Univ Warsaw, Dept Diagnost Imaging, PL-03242 Warsaw, Poland
[2] Hosp Solec, Dept Proctol, Warsaw, Poland
[3] Postgrad Med Educ Ctr, Warsaw, Poland
关键词
Three-dimensional endoanal ultrasonography; Volume render mode; Anal abscess; Fistula-in-ano; ENDOSONOGRAPHY; ULTRASOUND; ANO; CLASSIFICATION; ENHANCEMENT;
D O I
10.1007/DCR.0b013e3181ff44de
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
OBJECTIVE: This study aimed to evaluate the accuracy of a 3-dimensional volume render mode endoanal ultrasonography in the assessment of anal abscesses and fistulas. PATIENTS AND METHODS: Three-dimensional endoanal ultrasonography was performed preoperatively in 62 patients with clinical diagnoses of an anal abscess and/or an anal fistula. The accuracy of a volume render mode endoanal ultrasonography was evaluated blindly by 2 observers through a retrospective analysis of all the stored images of anal abscesses and fistulas. Differences in classification of the type of anal abscesses and in determination of the type and location of internal openings of anal fistulas were assessed. RESULTS: In classification of the primary tract, the agreement between the volume render mode endoanal ultrasonography and surgery was much higher than that for the 3-dimensional endoanal ultrasonography (marginal homogeneity test P > .1, kappa = 0.96, and marginal homogeneity test P = .0048, kappa = 0.28, respectively). In localizing the internal openings and in classifying anal abscesses, the agreement for both methods with surgery was identical. The interobserver agreement showed complete agreement (100%) with regard to luminance and thickness parameters and very high accuracy for the opacity and filter parameters. CONCLUSIONS: This study demonstrated that volume render mode endoanal ultrasonography is a useful adjunct method to the 3-dimensional endoanal ultrasonography, showing better classification results of the types of anal fistulas.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 31 条
  • [1] Agresti A., 1990, CATEGORICAL DATA ANA
  • [2] Value of hydrogen peroxide enhancement of three-dimensional endoanal ultrasound in fistula-in-ano
    Buchanan, GN
    Bartram, CI
    Williams, AB
    Halligan, S
    Cohen, CRG
    [J]. DISEASES OF THE COLON & RECTUM, 2005, 48 (01) : 141 - 147
  • [3] ANAL ENDOSONOGRAPHY FOR RECURRENT ANAL FISTULAS - IMAGE-ENHANCEMENT WITH HYDROGEN-PEROXIDE
    CHEONG, DMO
    NOGUERAS, JJ
    WEXNER, SD
    JAGELMAN, DG
    [J]. DISEASES OF THE COLON & RECTUM, 1993, 36 (12) : 1158 - 1160
  • [4] Endosonographic criteria for an internal opening of fistula-in-ano
    Cho, DY
    [J]. DISEASES OF THE COLON & RECTUM, 1999, 42 (04) : 515 - 518
  • [5] CORMAN ML, 1984, COLON RECTAL SURG
  • [6] Felt-Bersma Richelle J F, 2008, Expert Rev Gastroenterol Hepatol, V2, P587, DOI 10.1586/17474124.2.4.587
  • [7] Fernández-Frías AM, 2006, REV ESP ENFERM DIG, V98, P573, DOI 10.4321/s1130-01082006000800002
  • [8] Anal fistula surgery - Factors associated with recurrence and incontinence
    GarciaAguilar, J
    Belmonte, C
    Wong, WD
    Goldberg, SM
    Madoff, RD
    [J]. DISEASES OF THE COLON & RECTUM, 1996, 39 (07) : 723 - 729
  • [9] The role of three-dimensional endoluminal ultrasound imaging in the evaluation of anorectal diseases: a review
    Gravante, Gianpiero
    Giordano, Pasquale
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2008, 22 (07): : 1570 - 1578
  • [10] Imaging of fistula in ano
    Halligan, S
    Stoker, J
    [J]. RADIOLOGY, 2006, 239 (01) : 18 - 33