Smart Glasses for Radial Arterial Catheterization in Pediatric Patients: A Randomized Clinical Trial

被引:21
作者
Jang, Young-Eun [1 ]
Cho, Sung-Ae [2 ]
Ji, Sang-Hwan [1 ]
Kim, Eun-Hee [1 ]
Lee, Ji-Hyun [1 ]
Kim, Hee-Soo [1 ]
Kim, Jin-Tae [1 ]
机构
[1] Seoul Natl Univ, Coll Med, Seoul Natl Univ Hosp, Dept Anesthesiol & Pain Med, Seoul, South Korea
[2] Konyang Univ Hosp, Dept Anesthesiol & Pain Med, Daejeon, South Korea
关键词
VENOUS ACCESS; CANNULATION; GUIDELINES; SOCIETY;
D O I
10.1097/ALN.0000000000003914
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Hand-eye coordination and ergonomics are important for the success of delicate ultrasound-guided medical procedures. These can be improved using smart glasses (head-mounted display) by decreasing the head movement on the ultrasound screen. The hypothesis was that the smart glasses could improve the success rate of ultrasound-guided pediatric radial arterial catheterization. Methods: This prospective, single-blinded, randomized controlled, single-center study enrolled pediatric patients (n = 116, age less than 2 yr) requiring radial artery cannulation during general anesthesia. The participants were randomized into the ultrasound screen group (control) or the smart glasses group. After inducing general anesthesia, ultrasound-guided radial artery catheterization was performed. The primary outcome was the first-attempt success rate. The secondary outcomes included the first-attempt procedure time, the overall complication rate, and operators' ergonomic satisfaction (5-point scale). Results: In total, 116 children were included in the analysis. The smart glasses group had a higher first-attempt success rate than the control group (87.9% [51/58] vs. 72.4% [42/58]; P = 0.036; odds ratio, 2.78; 95% CI, 1.04 to 7.4; absolute risk reduction, -15.5%; 95% CI, -29.8 to -12.8%). The smart glasses group had a shorter first-attempt procedure time (median, 33 s; interquartile range, 23 to 47 s; range, 10 to 141 s) than the control group (median, 43 s; interquartile range, 31 to 67 s; range, 17 to 248 s; P = 0.007). The overall complication rate was lower in the smart glasses group than in the control group (5.2% [3/58] vs. 29.3% [17/58]; P = 0.001; odds ratio, 0.132; 95% CI, 0.036 to 0.48; absolute risk reduction, 24.1%; 95% CI, 11.1 to 37.2%). The proportion of positive ergonomic satisfaction (4 = good or 5 = best) was higher in the smart glasses group than in the control group (65.5% [38/58] vs. 20.7% [12/58]; P<0.001; odds ratio, 7.3; 95% CI, 3.16 to 16.8; absolute risk reduction, -44.8%; 95% CI, -60.9% to -28.8%). Conclusions: Smart glasses-assisted ultrasound-guided radial artery catheterization improved the first-attempt success rate and ergonomic satisfaction while reducing the first-attempt procedure time and overall complication rates in small pediatric patients.
引用
收藏
页码:612 / 620
页数:9
相关论文
共 13 条
[1]  
Jang YE, 2020, ANESTHESIOLOGY, V133, P53, DOI [10.1097/ALN.0000000000003336, 10.1097/ALN.0000000000003308]
[2]   Posterior Tibial Artery as an Alternative to the Radial Artery for Arterial Cannulation Site in Small Children A Randomized Controlled Study [J].
Kim, Eun-Hee ;
Lee, Ji-Hyun ;
Song, In-Kyung ;
Kim, Jin-Tae ;
Lee, Won-Jong ;
Kim, Hee-Soo .
ANESTHESIOLOGY, 2017, 127 (03) :423-431
[3]   European Society of Anaesthesiology guidelines on peri-operative use of ultrasound-guided for vascular access (PERSEUS vascular access) [J].
Lamperti, Massimo ;
Biasucci, Daniele Guerino ;
Disma, Nicola ;
Pittiruti, Mauro ;
Breschan, Christian ;
Vailati, Davide ;
Subert, Matteo ;
Traskaite, Vilma ;
Macas, Andrius ;
Estebe, Jean-Pierre ;
Fuzier, Regis ;
Boselli, Emmanuel ;
Hopkins, Philip .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2020, 37 (05) :344-376
[4]   Use of smart glasses for ultrasound-guided peripheral venous access: a randomized controlled pilot study [J].
Lim, Hyunmook ;
Kim, Min Joung ;
Park, Joon Min ;
Kim, Kyung Hwan ;
Park, Junseok ;
Shin, Dong Wun ;
Kim, Hoon ;
Jeon, Woochan ;
Kim, Hyunjong ;
Kim, Jungeon .
CLINICAL AND EXPERIMENTAL EMERGENCY MEDICINE, 2019, 6 (04) :356-361
[5]   Ultrasound-guided versus palpation-guided radial artery catheterization in adult population: A systematic review and meta-analysis of randomized controlled trials [J].
Pacha, Homam Moussa ;
Alahdab, Fares ;
Al-Khadra, Yasser ;
Idris, Amr ;
Rabbat, Firas ;
Darmoch, Fahed ;
Soud, Mohamad ;
Zaitoun, Anwar ;
Kaki, Amir ;
Rao, Sunil V. ;
Kwok, Chun Shing ;
Mamas, Mamas A. ;
Alraies, M. Chadi .
AMERICAN HEART JOURNAL, 2018, 204 :1-8
[6]  
Przkora R, 2021, PAIN PHYSICIAN, V24, P83
[7]   Acoustic Shadowing Facilitates Ultrasound-guided Radial Artery Cannulation in Young Children [J].
Quan, ZheFeng ;
Zhang, Liang ;
Zhou, Chen ;
Chi, Ping ;
He, HaiLi ;
Li, Ying .
ANESTHESIOLOGY, 2019, 131 (05) :1018-1024
[8]   Head-Mounted Display Use in Surgery: A Systematic Review [J].
Rahman, Rafa ;
Wood, Matthew E. ;
Qian, Long ;
Price, Carrie L. ;
Johnson, Alex A. ;
Osgood, Greg M. .
SURGICAL INNOVATION, 2020, 27 (01) :88-100
[9]   Short-axis/out-of-plane or long-axis/in-plane ultrasound-guided arterial cannulation in children A randomised controlled trial [J].
Song, In-Kyung ;
Choi, Jung-Yoon ;
Lee, Ji-Hyun ;
Kim, Eun-Hee ;
Kim, Hyun-Jung ;
Kim, Hee-Soo ;
Kim, Jin-Tae .
EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2016, 33 (07) :522-527
[10]  
Tolu S., 2019, Ann Med Res, V26, P1406, DOI DOI 10.5455/ANNALSMEDRES.2019.04.211