Accurate Identification of Klebsiella variicola by MALDI-TOF Mass Spectrometry in Clinical Microbiology Laboratories

被引:7
|
作者
Ohama, Yuki [1 ]
Nomura, Yusuke [1 ]
Mizoguchi, Miyuki [1 ]
Higurashi, Yoshimi [1 ]
Okamoto, Koh [2 ]
Harada, Sohei [1 ]
机构
[1] Univ Tokyo Hosp, Dept Infect Control & Prevent, Tokyo, Japan
[2] Univ Tokyo Hosp, Dept Infect Dis, Tokyo, Japan
来源
MICROBIOLOGY SPECTRUM | 2022年 / 10卷 / 05期
关键词
Klebsiella pneumoniae; Klebsiella quasipneumoniae; Klebsiella variicola; MALDI-TOF; PCR;
D O I
10.1128/spectrum.02844-22
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
Recent widespread use of bacterial whole-genome sequencing analysis has resulted in the proposal of novel bacterial species and reclassification of taxonomy. Accurate methods for identification of bacterial species in clinical microbiology laboratories are essential to accumulate information on the clinical characteristics of each bacterial species. Klebsiella variicola is a member of the Klebsiella pneumoniae complex, and its association with human infections has been increasingly recognized, but accurate identification methods approved for use in clinical microbiology laboratories have been limited thus far. Klebsiella variicola is a pathogen that is increasingly recognized as being associated with human infections, but the methods available to clinical microbiology laboratories for accurate identification are limited. In this study, we assessed the accuracy of identification of K. variicola by matrix-assisted laser desorption ionization-time of flight (MALDI-TOF) mass spectrometry using genetic identification with multiplex PCR as the reference method. Antimicrobial susceptibilities and virulence of K. variicola strains were also investigated. Fifty-five Klebsiella pneumoniae, 26 K. variicola, and 2 Klebsiella quasipneumoniae clinical strains were used for evaluation. Both MALDI Biotyper with library version 9 and Klebsiella MALDI TypeR, a web-based species identification tool using MALDI-TOF data, accurately identified all K. variicola strains. In addition, two strains of K. quasipneumoniae were accurately identified with Klebsiella MALDI TypeR. Whole-genome sequencing confirmed the accurate identification to the subspecies level by Klebsiella MALDI TypeR for four strains (two strains each of K. variicola subsp. variicola and K. quasipneumoniae subsp. similipneumoniae). While 13 strains, 3 strains, and 1 strain of K. pneumoniae showed nonsusceptibility to ampicillin-sulbactam, ceftriaxone, and meropenem, respectively, all strains of K. variicola were susceptible to all tested antimicrobial agents. Although two K. variicola strains were positive for the string test, no K. variicola strains harbored any of the genes associated with hypervirulence of K. pneumoniae. Accurate identification of the K. pneumoniae complex, including K. variicola, by MALDI-TOF in clinical microbiology laboratories is expected to clarify the clinical characteristics of each species in the future. IMPORTANCE Recent widespread use of bacterial whole-genome sequencing analysis has resulted in the proposal of novel bacterial species and reclassification of taxonomy. Accurate methods for identification of bacterial species in clinical microbiology laboratories are essential to accumulate information on the clinical characteristics of each bacterial species. Klebsiella variicola is a member of the Klebsiella pneumoniae complex, and its association with human infections has been increasingly recognized, but accurate identification methods approved for use in clinical microbiology laboratories have been limited thus far. The findings of the present study suggest that K. variicola can be accurately identified by matrix-assisted laser desorption ionization-time of flight mass spectrometry using updated library or web-based identification tools. Accurate identification will promote exploration of clinical characteristics of K. variicola.
引用
收藏
页数:5
相关论文
共 50 条
  • [21] Identification of filamentous fungi including dermatophytes using MALDI-TOF mass spectrometry
    Hamal, Petr
    Vavrova, Anna
    Mrazek, Jakub
    Svobodova, Lucie
    FOLIA MICROBIOLOGICA, 2022, 67 (01) : 55 - 61
  • [22] Cereal variety identification using MALDI-TOF mass spectrometry SNP genotyping
    Pattemore, J. A.
    Rice, N.
    Marshall, D. F.
    Waugh, R.
    Henry, R. J.
    JOURNAL OF CEREAL SCIENCE, 2010, 52 (03) : 356 - 361
  • [23] Integrating Machine Learning with MALDI-TOF Mass Spectrometry for Rapid and Accurate Antimicrobial Resistance Detection in Clinical Pathogens
    Lopez-Cortes, Xaviera A.
    Manriquez-Troncoso, Jose M.
    Sepulveda, Alejandra Yanez
    Soto, Patricio Suazo
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2025, 26 (03)
  • [24] High performance MALDI-TOF mass spectrometry for proteomics
    Vestal, Marvin
    Hayden, Kevin
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 268 (2-3) : 83 - 92
  • [25] Impact of mass spectrometry by MALDI-TOF MS for the rapid identification of aerobic and anaerobic bacteria of clinical importance
    Legarraga, Paulette
    Moraga, Marcela
    Lam, Marusella
    Geoffroy, Enrique
    Zumaran, Cecilia
    Garcia, Patricia
    REVISTA CHILENA DE INFECTOLOGIA, 2013, 30 (02): : 140 - 146
  • [26] An identification of MARK inhibitors using high throughput MALDI-TOF mass spectrometry
    Hruba, Lenka
    Polishchuk, Pavel
    Das, Viswanath
    Hajduch, Marian
    Dzubak, Petr
    BIOMEDICINE & PHARMACOTHERAPY, 2022, 146
  • [27] Analysis of intact glucosinolates by MALDI-TOF mass spectrometry
    Botting, CH
    Davidson, NE
    Griffiths, DW
    Bennett, RN
    Botting, NP
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2002, 50 (05) : 983 - 988
  • [28] Automatic antibiotic resistance prediction in Klebsiella pneumoniae based on MALDI-TOF mass
    Guerrero-Lopez, Alejandro
    Sevilla-Salcedo, Carlos
    Candela, Ana
    Hernandez-Garcia, Marta
    Cercenado, Emilia
    Olmos, Pablo M.
    Canton, Rafael
    Munoz, Patricia
    Gomez-Verdejo, Vanessa
    del Campo, Rosa
    Rodriguez-Sanchez, Belen
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2023, 118
  • [29] Discrimination of Bacillus cereus Group Members by MALDI-TOF Mass Spectrometry
    Manzulli, Viviana
    Rondinone, Valeria
    Buchicchio, Alessandro
    Serrecchia, Luigina
    Cipolletta, Dora
    Fasanella, Antonio
    Parisi, Antonio
    Difato, Laura
    Iatarola, Michela
    Aceti, Angela
    Poppa, Elena
    Tolve, Francesco
    Pace, Lorenzo
    Petruzzi, Fiorenza
    Della Rovere, Ines
    Raele, Donato Antonio
    Del Sambro, Laura
    Giangrossi, Luigi
    Galante, Domenico
    MICROORGANISMS, 2021, 9 (06)
  • [30] Accurate mass measurements using MALDI-TOF with delayed extraction
    Takach, EJ
    Hines, WM
    Patterson, DH
    Juhasz, P
    Falick, AM
    Vestal, ML
    Martin, SA
    JOURNAL OF PROTEIN CHEMISTRY, 1997, 16 (05): : 363 - 369