Intraoperative Anterior Segment Optical Coherence Tomography in the Management of Cataract Surgery: State of the Art

被引:4
作者
Toro, Mario Damiano [1 ,2 ]
Milan, Serena [3 ]
Tognetto, Daniele [3 ]
Rejdak, Robert [2 ]
Costagliola, Ciro [4 ]
Zweifel, Sandrine Anne [5 ]
Posarelli, Chiara [6 ]
Figus, Michele [6 ]
Rejdak, Magdalena [7 ]
Avitabile, Teresio [8 ]
Carnevali, Adriano [9 ]
Giglio, Rosa [3 ]
机构
[1] Univ Naples Federico II, Dept Publ Hlth, Eye Clin, I-80131 Naples, Italy
[2] Med Univ Lublin, Chair & Dept Gen & Pediat Ophthalmol, PL-20079 Lublin, Poland
[3] Univ Trieste, Dept Med Surg & Hlth Sci, Eye Clin, I-34134 Trieste, Italy
[4] Univ Naples Federico II, Dept Neurosci & Reprod & Odontostomatol Sci, Eye Clin, I-80131 Naples, Italy
[5] Univ Zurich, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[6] Univ Pisa, Dept Surg Med & Mol Pathol & Crit Care Med, I-56126 Pisa, Italy
[7] Med Univ Warsaw, Fac Med, PL-02091 Warsaw, Poland
[8] Univ Catania, Dept Ophthalmol, I-95124 Catania, Italy
[9] Magna Graecia Univ Catanzaro, Dept Ophthalmol, I-88100 Catanzaro, Italy
关键词
anterior segment OCT; intraoperative OCT; cataract surgery; surgical technique; INTRAOCULAR-LENS POSITION; PHACOEMULSIFICATION; CAPSULOTOMY; DETACHMENT; DYNAMICS;
D O I
10.3390/jcm11133867
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The introduction of non-invasive diagnostic tools in ophthalmology has significantly reshaped current clinical practice in different settings. Recently, different anterior segment (AS) intraoperative optical coherence tomography (i-OCT) systems have been employed for different interventional procedures including cataract surgery. Materials and Methods: A review on the use of AS i-OCT in the management of cataract surgery, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines (PRISMA). The level of evidence according to the Oxford Centre for Evidence-Based Medicine (OCEM) 2011 guidelines, and the quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system were assessed for all included articles. Results: Out of 6302 articles initially extracted, 6302 abstracts were identified for screening and 32 of these met the inclusion/exclusion criteria for full-text review; 19 articles were excluded. Conclusions: The use of AS i-OCT in cataract surgery, even if only a few studies have a high level or grade of evidence, may represent a useful tool for novel surgeons approaching phacoemulsification but also for expert ones for teaching purposes and to plan and manage complicated cases.
引用
收藏
页数:13
相关论文
共 50 条
[41]   Foveal thickness after cataract surgery – Measurement by optical coherence tomography [J].
B. Neumaier-Ammerer ;
K. E. Schmid ;
S. Binder .
Spektrum der Augenheilkunde, 2008, 22 :301-304
[42]   Application of anterior segment optical coherence tomography to identify eyes with posterior polar cataract at high risk for posterior capsule rupture [J].
Chan, Tommy C. Y. ;
Li, Emmy Y. M. ;
Yau, Jackey C. Y. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2014, 40 (12) :2076-2081
[43]   Anterior Segment Optical Coherence Tomography Assessment After Laser Capsulotomy in Pseudophakic Eyes With Pseudoexfoliation [J].
Eliacik, Mustafa ;
Erdur, Sevil Karaman ;
Gulkilik, Gokhan ;
Ozsutcu, Mustafa ;
Aras, Cengiz ;
Bayramlar, Huseyin ;
Aslan, Cemile Anil .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2016, 42 (05) :318-321
[44]   New IOL formula using anterior segment three-dimensional optical coherence tomography [J].
Yoo, Young-Sik ;
Whang, Woong-Joo ;
Kim, Hyun-Seung ;
Joo, Choun-Ki ;
Yoon, Geunyoung .
PLOS ONE, 2020, 15 (07)
[45]   Intraoperative optical coherence tomography imaging for assessment of anterior chamber gas fill [J].
Tseng, Michael ;
Thau, Avrey ;
Berkowitz, Carla ;
Ramaprasad, Abhijit ;
Basti, Surendra .
FRONTIERS IN OPHTHALMOLOGY, 2024, 4
[46]   Insights into scleral violaceous hue in anterior scleritis: anterior segment optical coherence tomography evaluation [J].
Sutra, Plern ;
Pothikamjorn, Thananop ;
Lopez, Sarah ;
Takhar, Jaskirat ;
Chongchareon, Mathinee ;
Keenan, Jeremy ;
Gonzales, John A. .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2025,
[47]   Determination and Validation of Thresholds of Anterior Chamber Parameters by Dedicated Anterior Segment Optical Coherence Tomography [J].
Melese, Ephrem K. ;
Chan, Jeffrey D. ;
Blieden, Lauren S. ;
Chuang, Alice Z. ;
Baker, Laura A. ;
Bell, Nicholas P. ;
Feldman, Robert M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2016, 169 :208-217
[48]   Characteristics and reproducibility of anterior chamber angle assessment by anterior-segment optical coherence tomography [J].
Kim, Dong Y. ;
Sung, Kyung R. ;
Kang, Sung Y. ;
Cho, Jung W. ;
Lee, Kyoung S. ;
Park, Seong B. ;
Kim, Soon T. ;
Kook, Michael S. .
ACTA OPHTHALMOLOGICA, 2011, 89 (05) :435-441
[49]   Anterior segment optical coherence tomography scanning protocols and corneal thickness repeatability [J].
Fisher, Damien ;
Collins, Michael J. ;
Vincent, Stephen J. .
CONTACT LENS & ANTERIOR EYE, 2020, 43 (05) :433-440
[50]   Diagnostic Potential of Anterior Segment Optical Coherence Tomography Scans for Pseudomonas Keratitis [J].
Khalil, Haidar ;
Bolz, Matthias ;
Waser, Klemens ;
Pomberger, Leon ;
Laubichler, Peter ;
Jirak, Paul ;
Hirnschall, Nino .
TRANSLATIONAL VISION SCIENCE & TECHNOLOGY, 2023, 12 (11)