Intraoperative Anterior Segment Optical Coherence Tomography in the Management of Cataract Surgery: State of the Art

被引:4
作者
Toro, Mario Damiano [1 ,2 ]
Milan, Serena [3 ]
Tognetto, Daniele [3 ]
Rejdak, Robert [2 ]
Costagliola, Ciro [4 ]
Zweifel, Sandrine Anne [5 ]
Posarelli, Chiara [6 ]
Figus, Michele [6 ]
Rejdak, Magdalena [7 ]
Avitabile, Teresio [8 ]
Carnevali, Adriano [9 ]
Giglio, Rosa [3 ]
机构
[1] Univ Naples Federico II, Dept Publ Hlth, Eye Clin, I-80131 Naples, Italy
[2] Med Univ Lublin, Chair & Dept Gen & Pediat Ophthalmol, PL-20079 Lublin, Poland
[3] Univ Trieste, Dept Med Surg & Hlth Sci, Eye Clin, I-34134 Trieste, Italy
[4] Univ Naples Federico II, Dept Neurosci & Reprod & Odontostomatol Sci, Eye Clin, I-80131 Naples, Italy
[5] Univ Zurich, Dept Ophthalmol, CH-8091 Zurich, Switzerland
[6] Univ Pisa, Dept Surg Med & Mol Pathol & Crit Care Med, I-56126 Pisa, Italy
[7] Med Univ Warsaw, Fac Med, PL-02091 Warsaw, Poland
[8] Univ Catania, Dept Ophthalmol, I-95124 Catania, Italy
[9] Magna Graecia Univ Catanzaro, Dept Ophthalmol, I-88100 Catanzaro, Italy
关键词
anterior segment OCT; intraoperative OCT; cataract surgery; surgical technique; INTRAOCULAR-LENS POSITION; PHACOEMULSIFICATION; CAPSULOTOMY; DETACHMENT; DYNAMICS;
D O I
10.3390/jcm11133867
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The introduction of non-invasive diagnostic tools in ophthalmology has significantly reshaped current clinical practice in different settings. Recently, different anterior segment (AS) intraoperative optical coherence tomography (i-OCT) systems have been employed for different interventional procedures including cataract surgery. Materials and Methods: A review on the use of AS i-OCT in the management of cataract surgery, following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines (PRISMA). The level of evidence according to the Oxford Centre for Evidence-Based Medicine (OCEM) 2011 guidelines, and the quality of evidence according to the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system were assessed for all included articles. Results: Out of 6302 articles initially extracted, 6302 abstracts were identified for screening and 32 of these met the inclusion/exclusion criteria for full-text review; 19 articles were excluded. Conclusions: The use of AS i-OCT in cataract surgery, even if only a few studies have a high level or grade of evidence, may represent a useful tool for novel surgeons approaching phacoemulsification but also for expert ones for teaching purposes and to plan and manage complicated cases.
引用
收藏
页数:13
相关论文
共 50 条
[21]   Anterior Segment Optical Coherence Tomography-Guided Management Algorithm for Descemet Membrane Detachment After Intraocular Surgery [J].
Sharma, Namrata ;
Gupta, Sandeep ;
Maharana, Prafulla ;
Shanmugam, Prakash ;
Nagpal, Ritu ;
Vajpayee, Rasik B. .
CORNEA, 2015, 34 (09) :1170-1174
[22]   Intraoperative Optical Coherence Tomography In Deep Anterior Lamellar Keratoplasty [J].
Siebelmann, S. ;
Steven, P. ;
Cursiefen, C. .
KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2016, 233 (06) :717-721
[23]   Anterior Segment Optical Coherence Tomography Characteristics in an Asian Population [J].
Sihota, Ramanjit ;
Vashisht, Praveen ;
Sharma, Ajay ;
Chakraborty, Swapna ;
Gupta, Viney ;
Pandey, Ravindra M. .
JOURNAL OF GLAUCOMA, 2012, 21 (03) :180-185
[24]   Optical coherence tomography angiography parameters after cataract surgery [J].
Nourinia, Ramin ;
Kiani, Ali ;
Hassanpour, Kiana ;
Nikkhah, Homayoun ;
Faramarzi, Amir ;
Emamverdi, Mehdi .
INTERNATIONAL OPHTHALMOLOGY, 2023, 43 (08) :2679-2686
[25]   Macular thickness after uneventful cataract surgery determined by optical coherence tomography [J].
von Jagow, Burkhard ;
Ohrloff, Christian ;
Kohnen, Thomas .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2007, 245 (12) :1765-1771
[26]   Optical coherence tomography angiography parameters after cataract surgery [J].
Ramin Nourinia ;
Ali Kiani ;
Kiana Hassanpour ;
Homayoun Nikkhah ;
Amir Faramarzi ;
Mehdi Emamverdi .
International Ophthalmology, 2023, 43 :2679-2686
[27]   Macular thickness after uneventful cataract surgery determined by optical coherence tomography [J].
Burkhard von Jagow ;
Christian Ohrloff ;
Thomas Kohnen .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2007, 245 :1765-1771
[28]   Real-time intraoperative dynamics of white cataract-intraoperative optical coherence tomography-guided classification and management [J].
Titiyal, Jeewan S. ;
Kaur, Manpreet ;
Shaikh, Farin ;
Goel, Siddhi ;
Bageshwar, Lalit M. S. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (04) :598-605
[29]   Intraoperative optical coherence tomography-guided assessment of hydro-dissection procedure during cataract surgery [J].
Yadav, Saumya ;
Mukhija, Ritika ;
Pujari, Amar ;
Tandon, Radhika .
INDIAN JOURNAL OF OPHTHALMOLOGY, 2020, 68 (08) :1647-+
[30]   Emerging Applications of Intraoperative Optical Coherence Tomography in Corneal Surgery: A Narrative Review [J].
Chatzimichail, Eleftherios ;
Chondrozoumakis, Georgios ;
Doroodgar, Farideh ;
Vounotrypidis, Efstathios ;
Panos, Georgios D. ;
Gatzioufas, Zisis .
JOURNAL OF CLINICAL MEDICINE, 2024, 13 (18)