An automatable format for accurate immunohematology testing by flow cytometry

被引:42
作者
Roback, JD [1 ]
Barclay, S [1 ]
Hillyer, CD [1 ]
机构
[1] Emory Univ, Sch Med, Dept Pathol & Lab Med, Transfus Med Program, Atlanta, GA 30322 USA
关键词
D O I
10.1046/j.1537-2995.2003.t01-1-00433.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: Current immunohematology testing methods have limitations including cost, throughput, and adaptability to automation. Furthermore, current automated and semiautomated workstations cannot accommodate many other tests relevant to blood transfusion. STUDY DESIGN AND METHODS: Authentic clinical samples from hospitalized patients were tested for ABO group, D type, and presence of RBC alloantibodies by column agglutination technology (CAT), standard tube methods, and a recently developed flow cytometry (FC) technique. Included were challenging samples with rouleaux, autoantibodies, mixed-field reactions, and weak antibodies. Antibody staining of RBCs for FC was initially performed in test tubes and subsequently in microtiter filter plates interfaced with a vacuum manifold. RESULTS: When antibody staining was performed in tubes, FC testing determined the correct ABO group and D type for 99.1 percent of 222 clinical samples, as compared to accuracies of 91.9 percent for CAT and 95.0 percent for standard tube testing. FC testing also detected 99.5 percent of clinically relevant RBC alloantibodies in 239 patient samples, as compared to 98.9 percent for CAT and 94.7 percent for LISS-IAT. Using the FC filter plate technique, 104 of 109 samples (95.4%) were correctly typed for ABO and D (the remaining five samples were read as "no type determined" due to RBC and serum testing discrepancies), and RBC alloantibodies of the IgG and IgM classes were correctly identified in 98.3 percent of samples. CONCLUSIONS: Optimized FC testing methods that are comparable in accuracy to standard CAT and tube methods are described. When used with filter plates, this methodology should allow rapid and cost-effective immunohematology testing of both patient and donor samples in an automated workstation format. The same workstation should support automation of other pretransfusion assays that can be analyzed by FC.
引用
收藏
页码:918 / 927
页数:10
相关论文
共 32 条
[1]   FLOW-CYTOMETRIC ANALYSIS OF ERYTHROCYTIC BLOOD GROUP-A ANTIGEN DENSITY PROFILE [J].
BERNEMAN, ZN ;
VANBOCKSTAELE, DR ;
UYTTENBROECK, WM ;
VANZAELEN, C ;
COLEDERGENT, J ;
MUYLLE, L ;
PEETERMANS, ME .
VOX SANGUINIS, 1991, 61 (04) :265-274
[2]  
BRECHER M, 2002, AABB TECHNICAL MANUA
[3]   Detection of fetal red cells in fetomaternal hemorrhage using a fetal hemoglobin monoclonal antibody by flow cytometry [J].
Davis, BH ;
Olsen, S ;
Bigelow, NC ;
Chen, JC .
TRANSFUSION, 1998, 38 (08) :749-756
[4]  
Drouvalakis KA, 1999, CYTOMETRY, V36, P46, DOI 10.1002/(SICI)1097-0320(19990501)36:1<46::AID-CYTO6>3.3.CO
[5]  
2-V
[6]   A multicenter study evaluating three methods for counting residual WBCs in WBC-reduced blood components: Nageotte hemocytometry, flow cytometry, and microfluorometry [J].
Dzik, S ;
Moroff, G ;
Dumont, L .
TRANSFUSION, 2000, 40 (05) :513-520
[7]   FLOW-CYTOMETRIC METHOD FOR COUNTING VERY LOW NUMBERS OF LEUKOCYTES IN PLATELET PRODUCTS [J].
DZIK, WH ;
RAGOSTA, A ;
CUSACK, WF .
VOX SANGUINIS, 1990, 59 (03) :153-159
[8]  
*FOOD DRUG ADM, 1995, GUID QUAL ASS BLOOD
[9]   APPLICATIONS OF FLOW-CYTOMETRY IN TRANSFUSION MEDICINE [J].
FREEDMAN, J ;
LAZARUS, AH .
TRANSFUSION MEDICINE REVIEWS, 1995, 9 (02) :87-109
[10]  
Garratty G, 1999, CYTOMETRY, V38, P259, DOI 10.1002/(SICI)1097-0320(19991215)38:6<259::AID-CYTO1>3.0.CO