An experimental investigation on intra-fractional organ motion effects in lung IMRT treatments

被引:241
作者
Jiang, SB [1 ]
Pope, C
Al Jarrah, KM
Kung, JH
Bortfeld, T
Chen, GTY
机构
[1] Massachusetts Gen Hosp, Dept Radiat Oncol, Boston, MA 02114 USA
[2] Harvard Univ, Sch Med, Boston, MA 02114 USA
关键词
D O I
10.1088/0031-9155/48/12/307
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Respiration-induced tumour motion can potentially compromise the use of intensity-modulated radiotherapy (IMRT) as a dose escalation tool for lung tumour treatment. We have experimentally investigated the intra-fractional or-an motion effects in lung IMRT treatments delivered by multi-leaf collimator (MLC). An in-house made motor-driven platform, which moves sinusoidally with an amplitude of 1 cm and a period of 4 s, was used to mimic tumour motion. Tumour motion was simulated along cranial-caudal direction while MLC leaves moved across the patient from left to right, as in most clinical cases. The dose to a point near the centre of the tumour mass was measured according to geometric and dosimetric parameters from two five-field lung IMRT plans. For each field, measurement was done for two dose rates (300 and 500 MU min(-1)), three MLC delivery modes (sliding window, step-and-shoot with 10 and 20 intensity levels) and eight equally spaced starting phases of tumour motion. The dose to the measurement point delivered from all five fields was derived for both a single fraction and 30 fractions by randomly sampling from measured dose values of each field at different initial phases. It was found that the mean dose to a moving tumour differs slightly (<2-3%) from that to a static tumour. The variation in breathing phase at the start of dose delivery results in a maximum variation around the mean dose of greater than 30% for one field. The full width at half maximum for the probability distribution of the point dose is up to 8% for all five fields in a single fraction, but less than 1-2% after 30 fractions. In general, lower dose rate can reduce the motion-caused dose variation and therefore might be preferable for lung IMRT when no motion mitigation techniques are used. From the two IMRT cases we studied where tumour motion is perpendicular to MLC leaf motion, the dose variation was found to be insensitive to the MLC delivery mode.
引用
收藏
页码:1773 / 1784
页数:12
相关论文
共 13 条
  • [1] Effects of intra-fraction motion on IMRT dose delivery: statistical analysis and simulation
    Bortfeld, T
    Jokivarsi, K
    Goitein, M
    Kung, J
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (13) : 2203 - 2220
  • [2] Intensity-modulated radiotherapy: Current status and issues of interest
    Boyer, AL
    Butler, EB
    DiPetrillo, TA
    Engler, MJ
    Fraass, B
    Grant, W
    Ling, CC
    Low, DA
    Mackie, TR
    Mohan, R
    Purdy, JA
    Roach, M
    Rosenman, JG
    Verhey, LJ
    Wong, JW
    Cumberlin, RL
    Stone, H
    Palta, JR
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 51 (04): : 880 - 914
  • [3] CHOI NCH, 1981, CANCER, V48, P101, DOI 10.1002/1097-0142(19810701)48:1<101::AID-CNCR2820480120>3.0.CO
  • [4] 2-S
  • [5] Delivery of intensity-modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods
    Chui, CS
    Chan, MF
    Yorke, E
    Spirou, S
    Ling, CC
    [J]. MEDICAL PHYSICS, 2001, 28 (12) : 2441 - 2449
  • [6] Intraindividual comparison of conventional three-dimensional radiotherapy and intensity modulated radiotherapy in the therapy of locally advanced non-small cell lung cancer - A planning study
    Marnitz, S
    Stuschke, M
    Bohsung, J
    Moys, A
    Reng, I
    Wurm, R
    Budach, V
    [J]. STRAHLENTHERAPIE UND ONKOLOGIE, 2002, 178 (11) : 651 - 658
  • [7] A new approach to dose escalation in non-small-cell lung cancer
    Mehta, M
    Scrimger, R
    Mackie, R
    Paliwal, B
    Chappell, R
    Fowler, J
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (01): : 23 - 33
  • [8] Synchronized moving aperture radiation therapy (SMART): average tumour trajectory for lung patients
    Neicu, T
    Shirato, H
    Seppenwoolde, Y
    Jiang, SB
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (05) : 587 - 598
  • [9] Issues in respiratory motion compensation during external-beam radiotherapy
    Ozhasoglu, C
    Murphy, MJ
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 52 (05): : 1389 - 1399
  • [10] Influence of respiration-induced organ motion on dose distributions in treatments using enhanced dynamic wedges
    Pemler, P
    Besserer, J
    Lombriser, N
    Pescia, R
    Schneider, U
    [J]. MEDICAL PHYSICS, 2001, 28 (11) : 2234 - 2240