Dual-Energy CT Iodine Mapping and 40-keV Monoenergetic Applications in the Diagnosis of Acute Bowel Ischemia

被引:77
作者
Lourenco, Pedro D. M. [1 ]
Rawski, Ryan [2 ]
Mohammed, Mohammed F. [1 ,3 ]
Khosa, Faisal [1 ]
Nicolaou, Savvas [1 ]
McLaughlin, Patrick [1 ]
机构
[1] Univ British Columbia, Vancouver Gen Hosp, Dept Radiol, 3350-950 W 10th Ave, Vancouver, BC V5Z 1M9, Canada
[2] Univ Calgary, Dept Radiol, Calgary, AB, Canada
[3] King Saud bin Abdulaziz Univ Hlth Sci, Abdominal Imaging Sect, Med Imaging Dept, King Abdullah Int Med Res Ctr,Minist Natl Guard,H, Riyadh, Saudi Arabia
关键词
acute intestinal ischemia; bowel ischemia; dual-energy CT; iodine mapping; virtual monoenergetic; ACUTE MESENTERIC ISCHEMIA; MDCT; MANAGEMENT;
D O I
10.2214/AJR.18.19554
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Sensitivity of CT of the abdomen for detection of acute bowel ischemia (ABI) can be as low as 60%. In this study, we assessed the diagnostic performance of iodinemap and monoenergetic (40-keV) images in patients with suspected ABI. MATERIALS AND METHODS. This retrospective study included 60 consecutive patients with suspected ABI who underwent a standardized imaging protocol dual-source dualenergy CT (DECT) over a 26-month period. Clinical and operative outcomes were recorded as the reference standard. Two abdominal radiologists who were unaware of clinical and surgical information independently assessed conventional CT images for ABI. After a time interval designed to reduce recall, readers reassessed conventional images with supplementary iodine-map and 40-keV postprocessed images. Quantitative ROI analysis was also performed. RESULTS. ABI was observed in 11 patients. For reader A, sensitivity was 63.6% (95% CI, 30.8-89.1%) when interpreting conventional images alone. Sensitivity for detection of ABI increased to 81.8% (95% CI, 48.2-97.7%) and 100% (95% CI, 71.5-100%) when iodine-map and 40-keV images were assessed, respectively. For reader B, no change in sensitivity was seen with either technique, but the number of false-positives were reduced with supplementary iodinemap and 40-keV postprocessed images. Interobserver agreement was fair with conventional images (lc = 0.29) but improved to moderate (x = 0.45) and substantial (x = 0.63) with iodinemap and 40-keV images, respectively. Quantitative assessment found significant differences in iodine uptake (1.01 +/- 0.55 mg/mL vs 3.04 +/- 1.19 mg/mL) and mean attenuation (75.2 +/- 38.4 HU vs 163.5 +/- 48.9 HU) between nonischemic and ischemic segments, respectively. CONCLUSION. Iodine-map and 40-keV monoenergetic images increase conspicuity of ABI, resulting in improved diagnostic accuracy compared with review of conventional CT images alone.
引用
收藏
页码:564 / 570
页数:7
相关论文
共 16 条
[1]  
Brandt LJ, 2015, AM J GASTROENTEROL, V110, P18, DOI [10.1038/ajg.2014.295, 10.1038/ajg.2014.395]
[2]   Surgical management of thrombotic acute intestinal ischemia [J].
Endean, ED ;
Barnes, SL ;
Kwolek, CJ ;
Minion, DJ ;
Schwarcz, TH ;
Mentzer, RM .
ANNALS OF SURGERY, 2001, 233 (06) :801-808
[3]   CT Diagnosis of Acute Mesenteric Ischemia from Various Causes [J].
Furukawa, Akira ;
Kanasaki, Shuzo ;
Kono, Naoaki ;
Wakamiya, Makoto ;
Tanaka, Toyohiko ;
Takahashi, Masashi ;
Murata, Kiyoshi .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2009, 192 (02) :408-416
[4]   Biphasic CT with mesenteric CT angiography in the evaluation of acute mesenteric ischemia: Initial experience [J].
Kirkpatrick, IDC ;
Kroeker, MA ;
Greenberg, HM .
RADIOLOGY, 2003, 229 (01) :91-98
[5]   Determinants of mortality and treatment outcome following surgical interventions for acute mesenteric ischemia [J].
Kougias, Panagiotis ;
Lau, Donald ;
El Sayed, Hosarn F. ;
Zhou, Wei ;
Huynh, Tam T. ;
Lin, Peter H. .
JOURNAL OF VASCULAR SURGERY, 2007, 46 (03) :467-474
[6]   MEASUREMENT OF OBSERVER AGREEMENT FOR CATEGORICAL DATA [J].
LANDIS, JR ;
KOCH, GG .
BIOMETRICS, 1977, 33 (01) :159-174
[7]   Dual-Source Dual-Energy MDCT of Pancreatic Adenocarcinoma: Initial Observations With Data Generated at 80 kVp and at Simulated Weighted-Average 120 kVp [J].
Macari, Michael ;
Spieler, Bradley ;
Kim, Danny ;
Graser, Anno ;
Megibow, Alec Jeffrey ;
Babb, James ;
Chandarana, Hersh .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2010, 194 (01) :W27-W32
[8]   Dual-Energy MDCT for Imaging the Renal Mass [J].
Mileto, Achille ;
Nelson, Rendon C. ;
Paulson, Erik K. ;
Marin, Daniele .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (06) :W640-W647
[9]   Multi-detector CT features of acute intestinal ischemia and their prognostic correlations [J].
Moschetta, Marco ;
Telegrafo, Michele ;
Rella, Leonarda ;
Ianora, Amato Antonio Stabile ;
Angelelli, Giuseppe .
WORLD JOURNAL OF RADIOLOGY, 2014, 6 (05) :130-138
[10]   Early Small-Bowel Ischemia: Dual-Energy CT Improves Conspicuity Compared with Conventional CT in a Swine Model [J].
Potretzke, Theodora A. ;
Brace, Christopher L. ;
Lubner, Meghan G. ;
Sampson, Lisa A. ;
Willey, Bridgett J. ;
Lee, Fred T., Jr. .
RADIOLOGY, 2015, 275 (01) :119-126